Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools

intelligent_platforms_proficy_real-time_information_portal

Source -

NVD

CNA CVEs -

0

ADP CVEs -

0

CISA CVEs -

0

NVD CVEs -

6
Related CVEsRelated VendorsRelated AssignersReports
6Vulnerabilities found

CVE-2013-0651
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5||MEDIUM
EPSS-0.34% / 55.88%
||
7 Day CHG~0.00%
Published-27 Jan, 2013 | 18:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Portal installation process in GE Intelligent Platforms Proficy Real-Time Information Portal stores sensitive information under the web root with insufficient access control, which allows remote attackers to read configuration files, and discover data-source credentials, via a direct request.

Action-Not Available
Vendor-gen/a
Product-intelligent_platforms_proficy_real-time_information_portaln/a
CVE-2013-0652
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5||MEDIUM
EPSS-0.30% / 52.69%
||
7 Day CHG~0.00%
Published-27 Jan, 2013 | 18:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

GE Intelligent Platforms Proficy Real-Time Information Portal does not restrict access to methods of an unspecified Java class, which allows remote attackers to obtain a username listing via an RMI call.

Action-Not Available
Vendor-gen/a
Product-intelligent_platforms_proficy_real-time_information_portaln/a
CVE-2012-3010
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-3.08% / 86.22%
||
7 Day CHG~0.00%
Published-01 Nov, 2012 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3021 and CVE-2012-3026.

Action-Not Available
Vendor-gen/a
Product-intelligent_platforms_proficy_real-time_information_portaln/a
CWE ID-CWE-20
Improper Input Validation
CVE-2012-3021
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-3.08% / 86.22%
||
7 Day CHG~0.00%
Published-01 Nov, 2012 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.

Action-Not Available
Vendor-gen/a
Product-intelligent_platforms_proficy_real-time_information_portaln/a
CWE ID-CWE-20
Improper Input Validation
CVE-2012-3026
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-3.08% / 86.22%
||
7 Day CHG~0.00%
Published-01 Nov, 2012 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3021.

Action-Not Available
Vendor-gen/a
Product-intelligent_platforms_proficy_real-time_information_portaln/a
CWE ID-CWE-20
Improper Input Validation
CVE-2012-0232
Assigner-CERT/CC
ShareView Details
Assigner-CERT/CC
CVSS Score-6.4||MEDIUM
EPSS-0.82% / 73.44%
||
7 Day CHG~0.00%
Published-15 Mar, 2012 | 18:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6, 3.0, 3.0 SP1, and 3.5 allows remote attackers to modify the configuration via crafted strings.

Action-Not Available
Vendor-gen/a
Product-intelligent_platforms_proficy_real-time_information_portaln/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')