Schneider Electric

Source -

CISACNA

BOS Name -

Schneider Electric SE

CNA CVEs -

248

ADP CVEs -

0

CISA CVEs -

1

NVD CVEs -

0
Related CVEsRelated ProductsRelated AssignersReports
249Vulnerabilities found

CVE-2025-8448
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-2.3||LOW
EPSS-0.02% / 4.37%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 13:58
Updated-20 Aug, 2025 | 15:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products.

Action-Not Available
Vendor-Schneider EelctricSchneider Electric SE
Product-EcoStruxureTM Building Operation Enterprise ServerEcoStruxureTM WorkstationEcoStruxureTM Enterprise Server
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2025-8449
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-4.1||MEDIUM
EPSS-0.03% / 5.16%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 13:55
Updated-20 Aug, 2025 | 17:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network.

Action-Not Available
Vendor-Schneider EelctricSchnieder ElectricSchneider Electric SE
Product-EcoStruxureTM Enterprise ServerEcoStruxureTM WorkstationEcoStruxureTM Building Operation Enterprise Server
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2025-54927
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-4.9||MEDIUM
EPSS-0.06% / 18.20%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 13:51
Updated-20 Aug, 2025 | 17:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards ModuleEcoStruxure™ Power Monitoring Expert (PME)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2025-54926
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.31% / 53.56%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 13:48
Updated-20 Aug, 2025 | 17:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards ModuleEcoStruxure™ Power Monitoring Expert (PME)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2025-54925
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.05% / 14.81%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 13:44
Updated-20 Aug, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards ModuleEcoStruxure™ Power Monitoring Expert (PME)
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2025-54924
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.07% / 20.97%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 13:39
Updated-20 Aug, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker sends a specially crafted document to a vulnerable endpoint.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards ModuleEcoStruxure™ Power Monitoring Expert (PME)
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2025-54923
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.40% / 59.59%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 13:30
Updated-20 Aug, 2025 | 17:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code execution and compromise of system integrity when authenticated users send crafted data to a network-exposed service that performs unsafe deserialization.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards ModuleEcoStruxure™ Power Monitoring Expert (PME)
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2025-8453
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.4||HIGH
EPSS-0.01% / 1.98%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 12:52
Updated-20 Aug, 2025 | 15:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and arbitrary code execution when a privileged engineer user with console access modifies a configuration file used by a root-level daemon to execute custom scripts.

Action-Not Available
Vendor-Schneider Electric SE
Product-Saitel DP RTUSaitel DR RTU
CWE ID-CWE-269
Improper Privilege Management
CVE-2025-5296
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7||HIGH
EPSS-0.02% / 2.42%
||
7 Day CHG~0.00%
Published-18 Aug, 2025 | 07:22
Updated-18 Aug, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-59: Improper Link Resolution Before File Access ('Link Following') vulnerability exists that could cause arbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file corruption, exposure of application and system information or persistent denial of service when a low-privileged attacker tampers with the installation folder.

Action-Not Available
Vendor-Schneider Electric SE
Product-SESU
CWE ID-CWE-59
Improper Link Resolution Before File Access ('Link Following')
CVE-2025-6625
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.05% / 15.80%
||
7 Day CHG+0.01%
Published-18 Aug, 2025 | 06:58
Updated-18 Aug, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device.

Action-Not Available
Vendor-Schneider Electric SE
Product-BMXNOR0200H: Ethernet / Serial RTU ModuleBMXNOC0401: Modicon M340 X80 Ethernet Communication modulesBMXNOE0100: Modbus/TCP Ethernet Modicon M340 moduleModicon M340BMXNOE0110: Modbus/TCP Ethernet Modicon M340 FactoryCast moduleBMXNGD0100: M580 Global Data module
CWE ID-CWE-20
Improper Input Validation
CVE-2025-6788
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 16.59%
||
7 Day CHG~0.00%
Published-11 Jul, 2025 | 11:09
Updated-22 Jul, 2025 | 15:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that exposes TGML diagram resources to the wrong control sphere, providing other authenticated users with potentially inappropriate access to TGML diagrams.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ Power Monitoring ExpertEcoStruxure™ Power Operation Advanced Reporting and Dashboards Module
CWE ID-CWE-668
Exposure of Resource to Wrong Sphere
CVE-2025-50124
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.02% / 4.11%
||
7 Day CHG~0.00%
Published-11 Jul, 2025 | 10:49
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the server is accessed by a privileged account via a console and through exploitation of a setup script.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ IT Data Center Expert
CWE ID-CWE-269
Improper Privilege Management
CVE-2025-50125
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-6.3||MEDIUM
EPSS-0.10% / 27.74%
||
7 Day CHG~0.00%
Published-11 Jul, 2025 | 10:45
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthenticated remote code execution when the server is accessed via the network with knowledge of hidden URLs and manipulation of host request header.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ IT Data Center Expert
CWE ID-CWE-918
Server-Side Request Forgery (SSRF)
CVE-2025-50123
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.04% / 11.88%
||
7 Day CHG~0.00%
Published-11 Jul, 2025 | 10:08
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote command execution by a privileged account when the server is accessed via a console and through exploitation of the hostname input.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ IT Data Center Expert
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2025-50122
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.9||HIGH
EPSS-0.02% / 3.89%
||
7 Day CHG-0.00%
Published-11 Jul, 2025 | 09:17
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the password generation algorithm is reverse engineered with access to installation or upgrade artifacts.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ IT Data Center Expert
CWE ID-CWE-331
Insufficient Entropy
CVE-2025-50121
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-9.5||CRITICAL
EPSS-0.89% / 74.62%
||
7 Day CHG~0.00%
Published-11 Jul, 2025 | 09:14
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created over the web interface HTTP when enabled. HTTP is disabled by default.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ IT Data Center Expert
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-6438
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-5.9||MEDIUM
EPSS-0.07% / 23.04%
||
7 Day CHG~0.00%
Published-11 Jul, 2025 | 09:06
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause manipulation of SOAP API calls and XML external entities injection resulting in unauthorized file access when the server is accessed via the network using an application account.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ IT Data Center Expert
CWE ID-CWE-611
Improper Restriction of XML External Entity Reference
CVE-2025-3117
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-5.1||MEDIUM
EPSS-0.04% / 10.50%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:43
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting configuration file paths that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.

Action-Not Available
Vendor-Schneider Electric SE
Product-Modicon Controllers M241/M251Modicon Controllers M262
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2025-3116
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.1||HIGH
EPSS-0.07% / 20.55%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:34
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an authenticated malicious user sends special malformed HTTPS request containing improper formatted body data to the controller.

Action-Not Available
Vendor-Schneider Electric SE
Product-Modicon Controllers M258 / LMC058Modicon Controllers M241/M251
CWE ID-CWE-20
Improper Input Validation
CVE-2025-3905
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-5.1||MEDIUM
EPSS-0.04% / 10.50%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:32
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.

Action-Not Available
Vendor-Schneider Electric SE
Product-Modicon Controllers M258 / LMC058Modicon Controllers M241/M251
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2025-3112
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.1||HIGH
EPSS-0.06% / 18.42%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:28
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause Denial of Service when an authenticated malicious user sends manipulated HTTPS Content-Length header to the webserver.

Action-Not Available
Vendor-Schneider Electric SE
Product-Modicon Controllers M241/M251
CWE ID-CWE-400
Uncontrolled Resource Consumption
CVE-2025-3899
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-5.1||MEDIUM
EPSS-0.02% / 4.37%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:25
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in Certificates page on Webserver that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.

Action-Not Available
Vendor-Schneider Electric SE
Product-Modicon Controllers M241/M251
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2025-3898
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.1||HIGH
EPSS-0.07% / 20.55%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:22
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an authenticated malicious user sends HTTPS request containing invalid data type to the webserver.

Action-Not Available
Vendor-Schneider Electric SE
Product-Modicon Controllers M241/M251Modicon Controllers M262
CWE ID-CWE-20
Improper Input Validation
CVE-2025-5743
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7||HIGH
EPSS-0.57% / 67.64%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:15
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-78: I Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote control over the charging station when an authenticated user modifies configuration parameters on the web server.

Action-Not Available
Vendor-Schneider Electric SE
Product-EVLink WallBox
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5742
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-5.1||MEDIUM
EPSS-0.04% / 10.50%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:11
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’) vulnerability exists when an authenticated user modifies configuration parameters on the web server

Action-Not Available
Vendor-Schneider Electric SE
Product-EVLink WallBox
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2025-5741
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-6.9||MEDIUM
EPSS-0.06% / 17.20%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:09
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file reads from the charging station. The exploitation of this vulnerability does require an authenticated session of the web server.

Action-Not Available
Vendor-Schneider Electric SE
Product-EVLink WallBox
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2025-5740
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.6||HIGH
EPSS-0.18% / 39.76%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 08:06
Updated-12 Jun, 2025 | 16:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file writes when an unauthenticated user on the web server manipulates file path.

Action-Not Available
Vendor-Schneider Electric SE
Product-EVLink WallBox
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2025-2875
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.09% / 27.13%
||
7 Day CHG~0.00%
Published-14 May, 2025 | 08:46
Updated-14 May, 2025 | 13:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality when an unauthenticated attacker manipulates controller’s webserver URL to access resources.

Action-Not Available
Vendor-Schneider Electric SE
Product-Modicon Controllers M258 / LMC058Modicon Controllers M241 / M251
CWE ID-CWE-610
Externally Controlled Reference to a Resource in Another Sphere
CVE-2025-3916
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-4.6||MEDIUM
EPSS-0.02% / 4.88%
||
7 Day CHG~0.00%
Published-13 May, 2025 | 08:35
Updated-13 May, 2025 | 19:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-121: Stack-based Buffer Overflow vulnerability exists that could cause local attackers being able to exploit these issues to potentially execute arbitrary code while the end user opens a malicious project file (SSD file) provided by the attacker.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure™ Power Build Rapsody software
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-2442
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.04% / 11.88%
||
7 Day CHG~0.00%
Published-09 Apr, 2025 | 10:26
Updated-09 Apr, 2025 | 13:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.

Action-Not Available
Vendor-Schneider Electric SE
Product-Trio Q Licensed Data Radio
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2025-2441
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-4.1||MEDIUM
EPSS-0.03% / 6.16%
||
7 Day CHG~0.00%
Published-09 Apr, 2025 | 10:23
Updated-09 Apr, 2025 | 13:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the product does not correctly initialize all data.

Action-Not Available
Vendor-Schneider Electric SE
Product-Trio Q Licensed Data Radio
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2025-2440
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-4.1||MEDIUM
EPSS-0.03% / 6.16%
||
7 Day CHG~0.00%
Published-09 Apr, 2025 | 10:20
Updated-09 Apr, 2025 | 13:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-922: Insecure Storage of Sensitive Information vulnerability exists that could potentially lead to unauthorized access of confidential data when a malicious user, having physical access and advanced information on the file system, sets the radio in factory default mode.

Action-Not Available
Vendor-Schneider Electric SE
Product-Trio Q Licensed Data Radio
CWE ID-CWE-922
Insecure Storage of Sensitive Information
CVE-2025-2223
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.4||HIGH
EPSS-0.04% / 9.64%
||
7 Day CHG~0.00%
Published-09 Apr, 2025 | 10:16
Updated-09 Apr, 2025 | 14:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could cause a loss of Confidentiality, Integrity and Availability of engineering workstation when a malicious project file is loaded by a user from the local system.

Action-Not Available
Vendor-Schneider Electric SE
Product-ConneXium Network Manager
CWE ID-CWE-20
Improper Input Validation
CVE-2025-2222
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.2||HIGH
EPSS-0.04% / 12.94%
||
7 Day CHG~0.00%
Published-09 Apr, 2025 | 10:12
Updated-09 Apr, 2025 | 14:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-552: Files or Directories Accessible to External Parties vulnerability over https exists that could leak information and potential privilege escalation following man in the middle attack.

Action-Not Available
Vendor-Schneider Electric SE
Product-ConneXium Network Manager
CWE ID-CWE-552
Files or Directories Accessible to External Parties
CVE-2025-1960
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.08% / 25.32%
||
7 Day CHG+0.01%
Published-12 Mar, 2025 | 15:33
Updated-13 Mar, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.

Action-Not Available
Vendor-Schneider Electric SE
Product-WebHMI – Deployed with EcoStruxure Power Automation System
CWE ID-CWE-1188
Initialization of a Resource with an Insecure Default
CVE-2025-0813
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7||HIGH
EPSS-0.05% / 13.79%
||
7 Day CHG~0.00%
Published-12 Mar, 2025 | 15:30
Updated-12 Mar, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-287: Improper Authentication vulnerability exists that could cause an Authentication Bypass when an unauthorized user without permission rights has physical access to the EPAS-UI computer and is able to reboot the workstation and interrupt the normal boot process.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure Power Automation System User Interface (EPAS-UI) - Secured Versions
CWE ID-CWE-287
Improper Authentication
CVE-2025-2002
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-4||MEDIUM
EPSS-0.02% / 3.81%
||
7 Day CHG~0.00%
Published-12 Mar, 2025 | 15:25
Updated-12 May, 2025 | 15:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-532: Insertion of Sensitive Information into Log Files vulnerability exists that could cause the disclosure of FTP server credentials when the FTP server is deployed, and the device is placed in debug mode by an administrative user and the debug files are exported from the device.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure Panel Server
CWE ID-CWE-532
Insertion of Sensitive Information into Log File
CVE-2025-0814
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-6.9||MEDIUM
EPSS-0.12% / 31.04%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 06:41
Updated-13 Feb, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could cause Denial-of-Service of the network services running on the product when malicious IEC61850-MMS packets are sent to the device. The core functionality of the breaker remains intact during the attack.

Action-Not Available
Vendor-Schneider Electric SE
Product-Enerlin’X IFE interface (LV434001)Enerlin’X eIFE (LV851001)
CWE ID-CWE-20
Improper Input Validation
CVE-2025-0815
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.1||HIGH
EPSS-0.06% / 16.94%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 06:39
Updated-13 Feb, 2025 | 14:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could cause Denial-of-Service of the product when malicious ICMPV6 packets are sent to the device.

Action-Not Available
Vendor-Schneider Electric SE
Product-Enerlin’X IFE interface (LV434001)Enerlin’X eIFE (LV851001)
CWE ID-CWE-20
Improper Input Validation
CVE-2025-0816
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.1||HIGH
EPSS-0.06% / 16.94%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 06:38
Updated-13 Feb, 2025 | 14:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could cause Denial-of-Service of the product when malicious IPV6 packets are sent to the device.

Action-Not Available
Vendor-Schneider Electric SE
Product-Enerlin’X IFE interface (LV434001)Enerlin’X eIFE (LV851001)
CWE ID-CWE-20
Improper Input Validation
CVE-2025-0327
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.5||HIGH
EPSS-0.03% / 5.13%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 06:20
Updated-13 Feb, 2025 | 14:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-269: Improper Privilege Management vulnerability exists for two services (of which one managing audit trail data and the other acting as server managing client request) that could cause a loss of Confidentiality, Integrity and Availability of engineering workstation when an attacker with standard privilege modifies the executable path of the windows services. To be exploited, services need to be restarted.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure Process Expert for AVEVA System PlatformEcoStruxure Process Expert
CWE ID-CWE-269
Improper Privilege Management
CVE-2025-1070
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.08% / 25.53%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 05:55
Updated-13 Feb, 2025 | 14:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could render the device inoperable when a malicious file is downloaded.

Action-Not Available
Vendor-Schneider Electric SE
Product-ASCO 5350 Eight Channel Remote AnnunciatorASCO 5310 Single-Channel Remote Annunciator
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2025-1060
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.04% / 9.74%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 05:53
Updated-13 Feb, 2025 | 15:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure of data when network traffic is being sniffed by an attacker.

Action-Not Available
Vendor-Schneider Electric SE
Product-ASCO 5350 Eight Channel Remote AnnunciatorASCO 5310 Single-Channel Remote Annunciator
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2025-1059
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.09% / 25.99%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 05:49
Updated-13 Feb, 2025 | 16:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-770: Allocation of Resources Without Limits or Throttling vulnerability exists that could cause communications to stop when malicious packets are sent to the webserver of the device.

Action-Not Available
Vendor-Schneider Electric SE
Product-ASCO 5350 Eight Channel Remote AnnunciatorASCO 5310 Single-Channel Remote Annunciator
CWE ID-CWE-770
Allocation of Resources Without Limits or Throttling
CVE-2025-1058
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-7.2||HIGH
EPSS-0.04% / 10.12%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 05:45
Updated-13 Feb, 2025 | 16:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-494: Download of Code Without Integrity Check vulnerability exists that could render the device inoperable when malicious firmware is downloaded.

Action-Not Available
Vendor-Schneider Electric SE
Product-ASCO 5350 Eight Channel Remote AnnunciatorASCO 5310 Single-Channel Remote Annunciator
CWE ID-CWE-494
Download of Code Without Integrity Check
CVE-2024-10083
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-6.8||MEDIUM
EPSS-0.04% / 13.17%
||
7 Day CHG~0.00%
Published-13 Feb, 2025 | 05:40
Updated-13 Feb, 2025 | 14:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of engineering workstation when specific driver interface is invoked locally by an authenticated user with crafted input.

Action-Not Available
Vendor-Schneider Electric SE
Product-Uni-Telway driverUni-Telway driver used in EcoStruxure Process Expert for AVEVA System PlatformUni-Telway driver used in EcoStruxure Control ExpertUni-Telway driver used in EcoStruxure Process ExpertUni-Telway driver used in OPC Factory Server
CWE ID-CWE-20
Improper Input Validation
CVE-2024-8401
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-5.4||MEDIUM
EPSS-0.03% / 7.25%
||
7 Day CHG~0.00%
Published-28 Jan, 2025 | 16:35
Updated-28 Jan, 2025 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’) vulnerability exists when an authenticated attacker modifies folder names within the context of the product.

Action-Not Available
Vendor-Schneider Electric SE
Product-EcoStruxure Power Operation (EPO) 2021EcoStruxure Power Operation (EPO) 2022 – Advanced Reporting and Dashboards ModuleEcoStruxure Power Operation (EPO) 2022EcoStruxure Power Monitoring Expert (PME) 2020EcoStruxure Power Operation (EPO) 2021 – Advanced Reporting and Dashboards ModuleEcoStruxure Power Monitoring Expert (PME) 2021EcoStruxure Power SCADA Operation 2020 (PSO) - Advanced Reporting and Dashboards Module
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2024-10498
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-6.9||MEDIUM
EPSS-0.10% / 28.80%
||
7 Day CHG+0.01%
Published-17 Jan, 2025 | 10:30
Updated-12 Feb, 2025 | 16:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality.

Action-Not Available
Vendor-Schneider Electric SE
Product-PowerLogic HDPM6000
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-10497
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.7||HIGH
EPSS-0.10% / 28.49%
||
7 Day CHG+0.01%
Published-17 Jan, 2025 | 10:27
Updated-12 Feb, 2025 | 16:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-639: Authorization Bypass Through User-Controlled Key vulnerability exists that could allow an authorized attacker to modify values outside those defined by their privileges (Elevation of Privileges) when the attacker sends modified HTTPS requests to the device.

Action-Not Available
Vendor-Schneider Electric SE
Product-PowerLogic HDPM6000
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2024-12703
Assigner-Schneider Electric
ShareView Details
Assigner-Schneider Electric
CVSS Score-8.5||HIGH
EPSS-0.32% / 54.21%
||
7 Day CHG~0.00%
Published-17 Jan, 2025 | 10:23
Updated-12 Feb, 2025 | 18:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when a non-admin authenticated user opens a malicious project file.

Action-Not Available
Vendor-Schneider Electric SE
Product-RemoteConnect and SCADAPack x70 Utilities
CWE ID-CWE-502
Deserialization of Untrusted Data