Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools

tenda

Source -

NVDADP

BOS Name -

Tenda Technology Co., Ltd.

CNA CVEs -

0

ADP CVEs -

506

CISA CVEs -

0

NVD CVEs -

1767
Related CVEsRelated ProductsRelated AssignersReports
1832Vulnerabilities found

CVE-2026-24114
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.62% / 46.30%
||
7 Day CHG~0.00%
Published-02 Mar, 2026 | 00:00
Updated-03 Mar, 2026 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Failure to validate `pPortMapIndex` may lead to buffer overflows when using `strcpy`.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20e_firmwarew20en/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-24110
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 34.88%
||
7 Day CHG~0.00%
Published-02 Mar, 2026 | 00:00
Updated-03 Mar, 2026 | 15:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may send overly long `addDhcpRules` data. When these rules enter the `addDhcpRule` function and are processed by `ret = sscanf(pRule, " %d\t%[^\t]\t%[^\n\r\t]", &dhcpsIndex, dhcpsIP, dhcpsMac);`, the lack of size validation for the rules could lead to buffer overflows in `dhcpsIndex`, `dhcpsIP`, and `dhcpsMac`.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20e_firmwarew20en/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-24107
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.16% / 80.32%
||
7 Day CHG~0.00%
Published-02 Mar, 2026 | 00:00
Updated-03 Mar, 2026 | 15:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Failure to validate the value of `usbPartitionName`, which is directly used in `doSystemCmd`, may lead to critical command injection vulnerabilities.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20e_firmwarew20en/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2026-24109
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.65% / 47.34%
||
7 Day CHG~0.00%
Published-02 Mar, 2026 | 00:00
Updated-05 Mar, 2026 | 16:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Tenda W20E V4.0br_V15.11.0.6. Attackers may exploit the vulnerability by controlling the value of `picName`. When this value is used in `sprintf` without validating variable sizes, it could lead to a buffer overflow vulnerability.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20e_firmwarew20en/a
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3400
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.85% / 54.52%
||
7 Day CHG~0.00%
Published-01 Mar, 2026 | 23:32
Updated-03 Mar, 2026 | 19:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC15 TextEditingConversion stack-based overflow

A security flaw has been discovered in Tenda AC15 up to 15.13.07.13. Affected by this issue is some unknown functionality of the file /goform/TextEditingConversion. The manipulation of the argument wpapsk_crypto2_4g results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac15AC15
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2026-3399
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-3.25% / 87.02%
||
7 Day CHG+2.36%
Published-01 Mar, 2026 | 23:02
Updated-03 Mar, 2026 | 17:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd GstDhcpSetSer fromGstDhcpSetSer buffer overflow

A vulnerability was identified in Tenda F453 1.0.0.3. Affected by this vulnerability is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer of the component httpd. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3398
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.63% / 46.63%
||
7 Day CHG~0.00%
Published-01 Mar, 2026 | 22:02
Updated-03 Mar, 2026 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd AdvSetWan fromAdvSetWan buffer overflow

A vulnerability was determined in Tenda F453 1.0.0.3. Affected is the function fromAdvSetWan of the file /goform/AdvSetWan of the component httpd. Executing a manipulation of the argument wanmode/PPPOEPassword can lead to buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3380
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.77% / 51.94%
||
7 Day CHG~0.00%
Published-01 Mar, 2026 | 03:02
Updated-05 May, 2026 | 18:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 L7Im frmL7ImForm buffer overflow

A vulnerability was found in Tenda F453 1.0.0.3. This issue affects the function frmL7ImForm of the file /goform/L7Im. The manipulation of the argument page results in buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3379
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.75% / 51.03%
||
7 Day CHG~0.00%
Published-01 Mar, 2026 | 02:32
Updated-05 May, 2026 | 18:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 SetIpBind fromSetIpBind buffer overflow

A vulnerability has been found in Tenda F453 1.0.0.3. This vulnerability affects the function fromSetIpBind of the file /goform/SetIpBind. The manipulation of the argument page leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3378
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.66% / 47.62%
||
7 Day CHG~0.00%
Published-01 Mar, 2026 | 02:02
Updated-05 May, 2026 | 18:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 qossetting fromqossetting buffer overflow

A flaw has been found in Tenda F453 1.0.0.3. This affects the function fromqossetting of the file /goform/qossetting. Executing a manipulation of the argument qos can lead to buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3377
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.75% / 51.03%
||
7 Day CHG~0.00%
Published-28 Feb, 2026 | 23:32
Updated-05 May, 2026 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 SafeUrlFilter fromSafeUrlFilter buffer overflow

A vulnerability was detected in Tenda F453 1.0.0.3. Affected by this issue is the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. Performing a manipulation of the argument page results in buffer overflow. The attack can be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3376
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.75% / 51.03%
||
7 Day CHG~0.00%
Published-28 Feb, 2026 | 23:02
Updated-05 May, 2026 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 SafeMacFilter fromSafeMacFilter buffer overflow

A security vulnerability has been detected in Tenda F453 1.0.0.3. Affected by this vulnerability is the function fromSafeMacFilter of the file /goform/SafeMacFilter. Such manipulation of the argument page leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3275
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.77% / 51.94%
||
7 Day CHG~0.00%
Published-27 Feb, 2026 | 01:32
Updated-27 Feb, 2026 | 18:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd addressNat fromAddressNat buffer overflow

A weakness has been identified in Tenda F453 1.0.0.3. This affects the function fromAddressNat of the file /goform/addressNat of the component httpd. Executing a manipulation of the argument entrys can lead to buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3274
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.94% / 57.18%
||
7 Day CHG~0.00%
Published-27 Feb, 2026 | 01:02
Updated-02 Mar, 2026 | 14:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd L7Prot frmL7ProtForm buffer overflow

A security flaw has been discovered in Tenda F453 1.0.0.3. Affected by this issue is the function frmL7ProtForm of the file /goform/L7Prot of the component httpd. Performing a manipulation of the argument page results in buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3273
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.63% / 46.63%
||
7 Day CHG~0.00%
Published-27 Feb, 2026 | 00:32
Updated-02 Mar, 2026 | 19:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd AdvSetWrlsafeset formWrlsafeset buffer overflow

A vulnerability was identified in Tenda F453 1.0.0.3. Affected by this vulnerability is the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component httpd. Such manipulation of the argument mit_ssid_index leads to buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3272
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.75% / 51.03%
||
7 Day CHG~0.00%
Published-27 Feb, 2026 | 00:02
Updated-27 Feb, 2026 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd DhcpListClient fromDhcpListClient buffer overflow

A vulnerability was determined in Tenda F453 1.0.0.3. Affected is the function fromDhcpListClient of the file /goform/DhcpListClient of the component httpd. This manipulation of the argument page causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3271
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.78% / 52.19%
||
7 Day CHG~0.00%
Published-27 Feb, 2026 | 00:02
Updated-27 Feb, 2026 | 18:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd P2pListFilterof fromP2pListFilter buffer overflow

A vulnerability was found in Tenda F453 1.0.0.3. This impacts the function fromP2pListFilter of the file /goform/P2pListFilterof of the component httpd. The manipulation of the argument page results in buffer overflow. The attack may be launched remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3169
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.63% / 46.64%
||
7 Day CHG~0.00%
Published-25 Feb, 2026 | 07:32
Updated-25 Feb, 2026 | 17:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd SafeEmailFilter fromSafeEmailFilter buffer overflow

A security vulnerability has been detected in Tenda F453 1.0.0.3. This impacts the function fromSafeEmailFilter of the file /goform/SafeEmailFilter of the component httpd. The manipulation of the argument page leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3168
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-3.25% / 87.02%
||
7 Day CHG~0.00%
Published-25 Feb, 2026 | 07:02
Updated-25 Feb, 2026 | 17:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd NatStaticSetting fromNatStaticSetting buffer overflow

A weakness has been identified in Tenda F453 1.0.0.3. This affects the function fromNatStaticSetting of the file /goform/NatStaticSetting of the component httpd. Executing a manipulation of the argument page can lead to buffer overflow. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3167
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.63% / 46.64%
||
7 Day CHG~0.00%
Published-25 Feb, 2026 | 07:02
Updated-25 Feb, 2026 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd webtypelibrary formWebTypeLibrary buffer overflow

A security flaw has been discovered in Tenda F453 1.0.0.3. The impacted element is the function formWebTypeLibrary of the file /goform/webtypelibrary of the component httpd. Performing a manipulation of the argument webSiteId results in buffer overflow. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3166
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.63% / 46.64%
||
7 Day CHG~0.00%
Published-25 Feb, 2026 | 06:32
Updated-25 Feb, 2026 | 21:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd RouteStatic fromRouteStatic buffer overflow

A vulnerability was identified in Tenda F453 1.0.0.3. The affected element is the function fromRouteStatic of the file /goform/RouteStatic of the component httpd. Such manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-3165
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.63% / 46.64%
||
7 Day CHG~0.00%
Published-25 Feb, 2026 | 06:02
Updated-25 Feb, 2026 | 21:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F453 httpd AdvSetWrlsafeset fromSetWifiGusetBasic buffer overflow

A vulnerability was determined in Tenda F453 1.0.0.3. Impacted is the function fromSetWifiGusetBasic of the file /goform/AdvSetWrlsafeset of the component httpd. This manipulation of the argument mit_ssid causes buffer overflow. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-f453f453_firmwareF453
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-27514
Assigner-VulnCheck
ShareView Details
Assigner-VulnCheck
CVSS Score-7.1||HIGH
EPSS-0.22% / 12.16%
||
7 Day CHG~0.00%
Published-23 Feb, 2026 | 16:27
Updated-11 May, 2026 | 23:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F3 Plaintext Credential Exposure in Configuration Download

Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoint also omits appropriate Cache-Control directives, which can allow the response to be stored in client-side caches and recovered by other local users or processes with access to cached browser data.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-f3_firmwaref3Tenda F3
CWE ID-CWE-201
Insertion of Sensitive Information Into Sent Data
CWE ID-CWE-525
Use of Web Browser Cache Containing Sensitive Information
CVE-2026-27513
Assigner-VulnCheck
ShareView Details
Assigner-VulnCheck
CVSS Score-5.1||MEDIUM
EPSS-0.10% / 1.11%
||
7 Day CHG~0.00%
Published-23 Feb, 2026 | 16:26
Updated-11 May, 2026 | 23:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F3 CSRF in Web Management Interface

Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a cross-site request forgery (CSRF) vulnerability in the web-based administrative interface. The interface does not implement anti-CSRF protections, allowing an attacker to induce an authenticated administrator to submit state-changing requests, which can result in unauthorized configuration changes.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-f3_firmwaref3Tenda F3
CWE ID-CWE-352
Cross-Site Request Forgery (CSRF)
CVE-2026-27512
Assigner-VulnCheck
ShareView Details
Assigner-VulnCheck
CVSS Score-5.1||MEDIUM
EPSS-0.18% / 8.08%
||
7 Day CHG~0.00%
Published-23 Feb, 2026 | 16:26
Updated-25 May, 2026 | 23:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F3 Reflected Script Execution via Missing nosniff Header

Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a content-type confusion vulnerability in the administrative interface. Responses omit the X-Content-Type-Options: nosniff header and include attacker-influenced content that can be reflected into the response body. Under affected browser behaviors, MIME sniffing may cause the response to be interpreted as active HTML, enabling script execution in the context of the administrative interface.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-f3_firmwaref3Tenda F3
CWE ID-CWE-116
Improper Encoding or Escaping of Output
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2026-27511
Assigner-VulnCheck
ShareView Details
Assigner-VulnCheck
CVSS Score-5.1||MEDIUM
EPSS-0.21% / 10.88%
||
7 Day CHG~0.00%
Published-23 Feb, 2026 | 16:25
Updated-11 May, 2026 | 23:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda F3 Clickjacking in Web Management Interface

Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a clickjacking vulnerability in the web-based administrative interface. The interface does not set the X-Frame-Options header, allowing attacker-controlled sites to embed administrative pages in an iframe and trick an authenticated administrator into unintended interactions that may result in unauthorized configuration changes.

Action-Not Available
Vendor-Shenzhen Tenda Technology Co., Ltd.Tenda Technology Co., Ltd.
Product-f3_firmwaref3Tenda F3
CWE ID-CWE-1021
Improper Restriction of Rendered UI Layers or Frames
CVE-2025-69700
Assigner-MITRE Corporation
ShareView Details
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-3.45% / 87.78%
||
7 Day CHG~0.00%
Published-23 Feb, 2026 | 00:00
Updated-24 Feb, 2026 | 20:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1203 V2.0.1.6 contains a stack-based buffer overflow vulnerability in the modify_add_client_prio function, which is reachable via the formSetClientPrio CGI handler.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1203_firmwarefh1203n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2930
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 22.36%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 06:02
Updated-27 Feb, 2026 | 18:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A18 Httpd Service UploadCfg webCgiGetUploadFile stack-based overflow

A vulnerability was identified in Tenda A18 15.13.07.13. The affected element is the function webCgiGetUploadFile of the file /cgi-bin/UploadCfg of the component Httpd Service. Such manipulation of the argument boundary leads to stack-based buffer overflow. The attack can be executed remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a18_firmwarea18A18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2911
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-3.08% / 86.28%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 03:02
Updated-23 Feb, 2026 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH451 GstDhcpSetSer buffer overflow

A vulnerability has been found in Tenda FH451 up to 1.0.0.9. This issue affects some unknown processing of the file /goform/GstDhcpSetSer. The manipulation leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh451fh451_firmwareFH451
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-2910
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-2.60% / 83.77%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 02:32
Updated-23 Feb, 2026 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG9 formPing6 stack-based overflow

A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg9hg9_firmwareHG9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2909
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.56% / 43.05%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 02:02
Updated-23 Feb, 2026 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow

A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg9hg9_firmwareHG9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2908
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.56% / 43.05%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 02:02
Updated-23 Feb, 2026 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow

A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg9hg9_firmwareHG9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2907
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.56% / 43.05%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 01:32
Updated-23 Feb, 2026 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow

A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg9hg9_firmwareHG9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2906
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.58% / 44.04%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 01:32
Updated-24 Feb, 2026 | 15:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow

A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg9hg9_firmwareHG9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2905
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.56% / 43.05%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 01:02
Updated-23 Feb, 2026 | 20:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow

A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-hg9hg9_firmwareHG9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2886
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.56% / 43.05%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 21:02
Updated-23 Feb, 2026 | 21:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A21 SetOnlineDevName set_device_name stack-based overflow

A weakness has been identified in Tenda A21 1.0.0.0. This affects the function set_device_name of the file /goform/SetOnlineDevName. This manipulation of the argument devName causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a21_firmwarea21A21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2877
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.49% / 39.35%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 18:32
Updated-23 Feb, 2026 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A18 Httpd Service WifiExtraSet strcpy stack-based overflow

A vulnerability has been found in Tenda A18 15.13.07.13. This affects the function strcpy of the file /goform/WifiExtraSet of the component Httpd Service. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a18_firmwarea18A18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2876
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.53% / 41.60%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 17:32
Updated-23 Feb, 2026 | 20:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A18 setBlackRule parse_macfilter_rule stack-based overflow

A vulnerability was determined in Tenda A18 15.13.07.13. This affects the function parse_macfilter_rule of the file /goform/setBlackRule. This manipulation of the argument deviceList causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a18_firmwarea18A18
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2874
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.57% / 43.67%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 17:32
Updated-23 Feb, 2026 | 20:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A21 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow

A flaw has been found in Tenda A21 1.0.0.0. Impacted is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. Executing a manipulation of the argument ssid can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a21_firmwarea21A21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2873
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.57% / 43.67%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 16:32
Updated-23 Feb, 2026 | 20:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A21 openSchedWifi setSchedWifi stack-based overflow

A vulnerability was detected in Tenda A21 1.0.0.0. This issue affects the function setSchedWifi of the file /goform/openSchedWifi. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a21_firmwarea21A21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2872
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.57% / 43.67%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 16:02
Updated-23 Feb, 2026 | 20:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A21 MAC Filtering Configuration Endpoint setBlackRule set_device_name stack-based overflow

A security vulnerability has been detected in Tenda A21 1.0.0.0. This vulnerability affects the function set_device_name of the file /goform/setBlackRule of the component MAC Filtering Configuration Endpoint. Such manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a21_firmwarea21A21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2871
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.68% / 48.83%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 15:32
Updated-23 Feb, 2026 | 20:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A21 SetIpMacBind fromSetIpMacBind stack-based overflow

A weakness has been identified in Tenda A21 1.0.0.0. This affects the function fromSetIpMacBind of the file /goform/SetIpMacBind. This manipulation of the argument list causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a21_firmwarea21A21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2870
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.59% / 44.59%
||
7 Day CHG~0.00%
Published-21 Feb, 2026 | 14:32
Updated-23 Feb, 2026 | 21:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda A21 formSetQosBand set_qosMib_list stack-based overflow

A security flaw has been discovered in Tenda A21 1.0.0.0. Affected by this issue is the function set_qosMib_list of the file /goform/formSetQosBand. The manipulation of the argument list results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-a21_firmwarea21A21
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2203
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 46.20%
||
7 Day CHG~0.00%
Published-09 Feb, 2026 | 02:02
Updated-23 Feb, 2026 | 09:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 Embedded Httpd Service fast_setting_wifi_set buffer overflow

A flaw has been found in Tenda AC8 16.03.33.05. Affected by this vulnerability is an unknown functionality of the file /goform/fast_setting_wifi_set of the component Embedded Httpd Service. This manipulation of the argument timeZone causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8_firmwareac8AC8
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-2202
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 46.20%
||
7 Day CHG~0.00%
Published-09 Feb, 2026 | 01:32
Updated-23 Feb, 2026 | 09:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC8 httpd WifiGuestSet fromSetWifiGusetBasic buffer overflow

A vulnerability was detected in Tenda AC8 16.03.33.05. Affected is the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet of the component httpd. The manipulation of the argument shareSpeed results in buffer overflow. The attack may be launched remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac8_firmwareac8AC8
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2026-2192
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.66% / 47.92%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 23:02
Updated-23 Feb, 2026 | 09:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9 formGetRebootTimer stack-based overflow

A security vulnerability has been detected in Tenda AC9 15.03.06.42_multi. Affected by this vulnerability is the function formGetRebootTimer. Such manipulation of the argument sys.schedulereboot.start_time/sys.schedulereboot.end_time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac9ac9_firmwareAC9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2191
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.66% / 47.92%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 22:32
Updated-23 Feb, 2026 | 09:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9 formGetDdosDefenceList stack-based overflow

A weakness has been identified in Tenda AC9 15.03.06.42_multi. Affected is the function formGetDdosDefenceList. This manipulation of the argument security.ddos.map causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made available to the public and could be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac9ac9_firmwareAC9
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2187
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.82% / 53.40%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 21:02
Updated-23 Feb, 2026 | 09:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 formSetQosBand set_qosMib_list stack-based overflow

A vulnerability was found in Tenda RX3 16.03.13.11. The affected element is the function set_qosMib_list of the file /goform/formSetQosBand. Performing a manipulation of the argument list results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2186
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.82% / 53.40%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 21:02
Updated-23 Feb, 2026 | 09:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 SetIpMacBind fromSetIpMacBind stack-based overflow

A vulnerability has been found in Tenda RX3 16.03.13.11. Impacted is the function fromSetIpMacBind of the file /goform/SetIpMacBind. Such manipulation of the argument list leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2185
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.69% / 48.96%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 20:32
Updated-23 Feb, 2026 | 09:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 MAC Filtering Configuration Endpoint setBlackRule set_device_name stack-based overflow

A flaw has been found in Tenda RX3 16.03.13.11. This issue affects the function set_device_name of the file /goform/setBlackRule of the component MAC Filtering Configuration Endpoint. This manipulation of the argument devName/mac causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2026-2181
Assigner-VulDB
ShareView Details
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.57% / 43.82%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 19:32
Updated-23 Feb, 2026 | 09:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 openSchedWifi stack-based overflow

A security flaw has been discovered in Tenda RX3 16.03.13.11. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. Performing a manipulation of the argument schedStartTime/schedEndTime results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • 36
  • 37
  • Next