CVE-2011-3330

Summary
Assigner-certcc
Assigner Org ID-37e5125f-f79b-445b-8fad-9564f167944b
Published At-04 Nov, 2011 | 21:00
Updated At-06 Aug, 2024 | 23:29
Rejected At-
Credits

Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:certcc
Assigner Org ID:37e5125f-f79b-445b-8fad-9564f167944b
Published At:04 Nov, 2011 | 21:00
Updated At:06 Aug, 2024 | 23:29
Rejected At:
▼CVE Numbering Authority (CNA)

Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://exchange.xforce.ibmcloud.com/vulnerabilities/70882
vdb-entry
x_refsource_XF
http://www.securityfocus.com/bid/50319
vdb-entry
x_refsource_BID
http://www.us-cert.gov/control_systems/pdf/ICSA-11-277-01.pdf
x_refsource_MISC
http://www.scada.schneider-electric.com/sites/scada/en/login/vijeo-citect-unitelway-windows-device-driver.page
x_refsource_CONFIRM
http://secunia.com/advisories/46534
third-party-advisory
x_refsource_SECUNIA
http://www.securitytracker.com/id?1026234
vdb-entry
x_refsource_SECTRACK
Hyperlink: https://exchange.xforce.ibmcloud.com/vulnerabilities/70882
Resource:
vdb-entry
x_refsource_XF
Hyperlink: http://www.securityfocus.com/bid/50319
Resource:
vdb-entry
x_refsource_BID
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-11-277-01.pdf
Resource:
x_refsource_MISC
Hyperlink: http://www.scada.schneider-electric.com/sites/scada/en/login/vijeo-citect-unitelway-windows-device-driver.page
Resource:
x_refsource_CONFIRM
Hyperlink: http://secunia.com/advisories/46534
Resource:
third-party-advisory
x_refsource_SECUNIA
Hyperlink: http://www.securitytracker.com/id?1026234
Resource:
vdb-entry
x_refsource_SECTRACK
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://exchange.xforce.ibmcloud.com/vulnerabilities/70882
vdb-entry
x_refsource_XF
x_transferred
http://www.securityfocus.com/bid/50319
vdb-entry
x_refsource_BID
x_transferred
http://www.us-cert.gov/control_systems/pdf/ICSA-11-277-01.pdf
x_refsource_MISC
x_transferred
http://www.scada.schneider-electric.com/sites/scada/en/login/vijeo-citect-unitelway-windows-device-driver.page
x_refsource_CONFIRM
x_transferred
http://secunia.com/advisories/46534
third-party-advisory
x_refsource_SECUNIA
x_transferred
http://www.securitytracker.com/id?1026234
vdb-entry
x_refsource_SECTRACK
x_transferred
Hyperlink: https://exchange.xforce.ibmcloud.com/vulnerabilities/70882
Resource:
vdb-entry
x_refsource_XF
x_transferred
Hyperlink: http://www.securityfocus.com/bid/50319
Resource:
vdb-entry
x_refsource_BID
x_transferred
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-11-277-01.pdf
Resource:
x_refsource_MISC
x_transferred
Hyperlink: http://www.scada.schneider-electric.com/sites/scada/en/login/vijeo-citect-unitelway-windows-device-driver.page
Resource:
x_refsource_CONFIRM
x_transferred
Hyperlink: http://secunia.com/advisories/46534
Resource:
third-party-advisory
x_refsource_SECUNIA
x_transferred
Hyperlink: http://www.securitytracker.com/id?1026234
Resource:
vdb-entry
x_refsource_SECTRACK
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cret@cert.org
Published At:04 Nov, 2011 | 21:55
Updated At:11 Apr, 2025 | 00:51

Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary2.07.2HIGH
AV:L/AC:L/Au:N/C:C/I:C/A:C
Type: Primary
Version: 2.0
Base score: 7.2
Base severity: HIGH
Vector:
AV:L/AC:L/Au:N/C:C/I:C/A:C
CPE Matches

Schneider Electric SE
schneider-electric
>>monitor_pro>>Versions up to 7.6(inclusive)
cpe:2.3:a:schneider-electric:monitor_pro:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>opc_factory_server>>Versions up to 3.34(inclusive)
cpe:2.3:a:schneider-electric:opc_factory_server:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>pl7_pro>>Versions up to 4.5(inclusive)
cpe:2.3:a:schneider-electric:pl7_pro:*:sp5:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>telemecanique_driver_pack>>Versions up to 2.6(inclusive)
cpe:2.3:a:schneider-electric:telemecanique_driver_pack:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>unity_pro>>Versions up to 6.0(inclusive)
cpe:2.3:a:schneider-electric:unity_pro:*:*:*:*:*:*:*:*
Schneider Electric SE
schneider-electric
>>vijeo_citect>>Versions up to 7.20(inclusive)
cpe:2.3:a:schneider-electric:vijeo_citect:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-119Primarynvd@nist.gov
CWE ID: CWE-119
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://secunia.com/advisories/46534cret@cert.org
Vendor Advisory
http://www.scada.schneider-electric.com/sites/scada/en/login/vijeo-citect-unitelway-windows-device-driver.pagecret@cert.org
Vendor Advisory
http://www.securityfocus.com/bid/50319cret@cert.org
N/A
http://www.securitytracker.com/id?1026234cret@cert.org
N/A
http://www.us-cert.gov/control_systems/pdf/ICSA-11-277-01.pdfcret@cert.org
US Government Resource
https://exchange.xforce.ibmcloud.com/vulnerabilities/70882cret@cert.org
N/A
http://secunia.com/advisories/46534af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
http://www.scada.schneider-electric.com/sites/scada/en/login/vijeo-citect-unitelway-windows-device-driver.pageaf854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
http://www.securityfocus.com/bid/50319af854a3a-2127-422b-91ae-364da2661108
N/A
http://www.securitytracker.com/id?1026234af854a3a-2127-422b-91ae-364da2661108
N/A
http://www.us-cert.gov/control_systems/pdf/ICSA-11-277-01.pdfaf854a3a-2127-422b-91ae-364da2661108
US Government Resource
https://exchange.xforce.ibmcloud.com/vulnerabilities/70882af854a3a-2127-422b-91ae-364da2661108
N/A
Hyperlink: http://secunia.com/advisories/46534
Source: cret@cert.org
Resource:
Vendor Advisory
Hyperlink: http://www.scada.schneider-electric.com/sites/scada/en/login/vijeo-citect-unitelway-windows-device-driver.page
Source: cret@cert.org
Resource:
Vendor Advisory
Hyperlink: http://www.securityfocus.com/bid/50319
Source: cret@cert.org
Resource: N/A
Hyperlink: http://www.securitytracker.com/id?1026234
Source: cret@cert.org
Resource: N/A
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-11-277-01.pdf
Source: cret@cert.org
Resource:
US Government Resource
Hyperlink: https://exchange.xforce.ibmcloud.com/vulnerabilities/70882
Source: cret@cert.org
Resource: N/A
Hyperlink: http://secunia.com/advisories/46534
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory
Hyperlink: http://www.scada.schneider-electric.com/sites/scada/en/login/vijeo-citect-unitelway-windows-device-driver.page
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory
Hyperlink: http://www.securityfocus.com/bid/50319
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: http://www.securitytracker.com/id?1026234
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: http://www.us-cert.gov/control_systems/pdf/ICSA-11-277-01.pdf
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
US Government Resource
Hyperlink: https://exchange.xforce.ibmcloud.com/vulnerabilities/70882
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

535Records found

CVE-2018-7522
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-10
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.7||MEDIUM
EPSS-0.07% / 20.99%
||
7 Day CHG~0.00%
Published-04 May, 2018 | 17:00
Updated-17 Sep, 2024 | 00:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.

Action-Not Available
Vendor-
Product-triconex_tricon_mp_3008triconex_tricon_mp_3008_firmwareTriconex Tricon
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-30066
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.00% / 0.15%
||
7 Day CHG~0.00%
Published-03 Apr, 2022 | 22:01
Updated-03 Aug, 2024 | 22:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.

Action-Not Available
Vendor-beldenn/a
Product-tofino_argon_fa-tsa-220-mm\/txeagle_20_tofino_943_987-504-mm\/txtofino_argon_fa-tsa-220-tx\/txtcsefea23f3f21_firmwareeagle_20_tofino_943_987-502_-tx\/mm_firmwareeagle_20_tofino_943_987-501-tx\/txtofino_argon_fa-tsa-220-mm\/tx_firmwaretofino_argon_fa-tsa-100-tx\/txtofino_xenon_security_appliance_firmwareeagle_20_tofino_943_987-501-tx\/tx_firmwaretcsefea23f3f21eagle_20_tofino_943_987-504-mm\/tx_firmwaretofino_argon_fa-tsa-220-tx\/mm_firmwaretofino_xenon_security_appliancetofino_argon_fa-tsa-100-tx\/tx_firmwareeagle_20_tofino_943_987-502_-tx\/mmtcsefea23f3f22_firmwaretofino_argon_fa-tsa-220-tx\/tx_firmwareeagle_20_tofino_943_987-505-mm\/mmtofino_argon_fa-tsa-220-tx\/mmtcsefea23f3f22eagle_20_tofino_943_987-505-mm\/mm_firmwaretofino_argon_fa-tsa-220-mm\/mmtcsefea23f3f20tofino_argon_fa-tsa-220-mm\/mm_firmwaretcsefea23f3f20_firmwaren/a
CWE ID-CWE-347
Improper Verification of Cryptographic Signature
CVE-2021-30061
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.01% / 0.41%
||
7 Day CHG~0.00%
Published-03 Apr, 2022 | 21:46
Updated-03 Aug, 2024 | 22:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.

Action-Not Available
Vendor-beldenn/a
Product-tofino_argon_fa-tsa-220-mm\/txeagle_20_tofino_943_987-504-mm\/txtofino_argon_fa-tsa-220-tx\/txtcsefea23f3f21_firmwareeagle_20_tofino_943_987-502_-tx\/mm_firmwareeagle_20_tofino_943_987-501-tx\/txtofino_argon_fa-tsa-220-mm\/tx_firmwaretofino_argon_fa-tsa-100-tx\/txtofino_xenon_security_appliance_firmwareeagle_20_tofino_943_987-501-tx\/tx_firmwaretcsefea23f3f21eagle_20_tofino_943_987-504-mm\/tx_firmwaretofino_argon_fa-tsa-220-tx\/mm_firmwaretofino_xenon_security_appliancetofino_argon_fa-tsa-100-tx\/tx_firmwareeagle_20_tofino_943_987-502_-tx\/mmtcsefea23f3f22_firmwaretofino_argon_fa-tsa-220-tx\/tx_firmwareeagle_20_tofino_943_987-505-mm\/mmtofino_argon_fa-tsa-220-tx\/mmtcsefea23f3f22eagle_20_tofino_943_987-505-mm\/mm_firmwaretofino_argon_fa-tsa-220-mm\/mmtcsefea23f3f20tofino_argon_fa-tsa-220-mm\/mm_firmwaretcsefea23f3f20_firmwaren/a
CVE-2017-9958
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.06% / 16.95%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper access control vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an improper handling of the system configuration can allow an attacker to execute arbitrary code under the context of root.

Action-Not Available
Vendor-Schneider Electric SE
Product-u.motion_builderU.Motion
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2017-7968
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.04% / 11.00%
||
7 Day CHG~0.00%
Published-19 May, 2017 | 15:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system's path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_indusoft_web_studioSchneider Electric Wonderware InduSoft Web Studio
CWE ID-CWE-276
Incorrect Default Permissions
CVE-2020-7544
Matching Score-8
Assigner-Schneider Electric
ShareView Details
Matching Score-8
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.04% / 10.03%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:05
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal Expert.

Action-Not Available
Vendor-n/a
Product-operator_terminal_expert_runtimeEcoStruxureª Operator Terminal Expert runtime (Vijeo XD)
CWE ID-CWE-269
Improper Privilege Management
CVE-2018-8872
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.1||HIGH
EPSS-0.80% / 73.08%
||
7 Day CHG~0.00%
Published-04 May, 2018 | 17:00
Updated-16 Sep, 2024 | 16:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.

Action-Not Available
Vendor-
Product-triconex_tricon_mp_3008triconex_tricon_mp_3008_firmwareTriconex Tricon
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7759
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.82% / 73.45%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.

Action-Not Available
Vendor-
Product-140cpu65160ctsxp573634mmodicon_m340_bmxp3420302h_firmware140cpu65160_firmwaretsxh5744m_firmwaremodicon_m340_bmxp342020h_firmwaretsxh5744m140cpu65160s_firmwaretsxp571634mcmodicon_m340_bmxp3420102cltsxp574634m_firmwaremodicon_m340_bmxp3420302_firmwaretsxp575634mtsxh5724mc_firmwaretsxp57304mc140cpu65860tsxp575634mc140cpu65160modicon_m340_bmxp3420302cl_firmwaretsxh5744mc_firmwaretsxp573634mc_firmwaremodicon_m340_bmxp342020_firmwaretsxp57454m_firmwaretsxp57254m_firmwaremodicon_m340_bmxp3420102_firmwaretsxp572634mtsxp57554mc_firmwaretsxp574634mtsxh5724mtsxp57304m_firmwaretsxp571634mc_firmwaretsxp57454mcmodicon_m340_bmxp341000h140cpu65160sbmxnor0200_firmwaremodicon_m340_bmxp3420302clbmxnor0200htsxp574634mc_firmwaretsxp57154mctsxp57154m_firmwaretsxp57154mtsxp576634mtsxh5744mctsxp57204mcmodicon_m340_bmxp342020140cpu31110modicon_m340_bmxp342020htsxp57354mc_firmwaretsxp57104m140cpu65150c_firmwaretsxp57354m140cpu65150_firmwaremodicon_m340_bmxp342000_firmware140cpu65860cbmxnor0200h_firmwaretsxp57204m_firmwaretsxp57204m140cpu65260tsxp571634m_firmwaretsxp573634mc140cpu43412uc140cpu65150tsxp571634mtsxp57304mc_firmware140cpu65860_firmwarebmxnor0200modicon_m340_bmxp341000h_firmware140cpu65260ctsxp57354mc140cpu65150c140cpu43412u_firmwaretsxh5724m_firmwaremodicon_m340_bmxp342000tsxp575634m_firmwaretsxp573634m_firmwaretsxp57204mc_firmwaretsxp57104mc_firmwaremodicon_m340_bmxp341000tsxh5724mc140cpu65260c_firmwaretsxp57254mc_firmware140cpu31110_firmware140cpu31110ctsxp57304mtsxp576634mcmodicon_m340_bmxp3420302htsxp574634mcmodicon_m340_bmxp3420102cl_firmwaretsxp572634mc_firmwaretsxp57454mc_firmwaretsxp576634mc_firmwaretsxp57554mctsxp575634mc_firmware140cpu65160c_firmwaretsxp576634m_firmware140cpu65260_firmwaremodicon_m340_bmxp3420302140cpu43412uc_firmwaretsxp57454mtsxp572634mcmodicon_m340_bmxp341000_firmwaretsxp57254mtsxp57104m_firmwaretsxp572634m_firmwaretsxp57554mtsxp57254mctsxp57354m_firmwaretsxp57104mctsxp57554m_firmwaremodicon_m340_bmxp3420102140cpu31110c_firmware140cpu43412utsxp57154mc_firmware140cpu65860c_firmwareModicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7780
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-0.54% / 66.72%
||
7 Day CHG~0.00%
Published-03 Jul, 2018 | 14:00
Updated-17 Sep, 2024 | 00:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".

Action-Not Available
Vendor-
Product-imp519-1er_firmwareimp319-1eribp319-1erimps110-1eibp519-1er_firmwareimp1110-1er_firmwareimps110-1eribp1110-1erimp519-1_firmwareimp519-1ibps110-1er_firmwareimp219-1_firmwareimp319-1_firmwareimps110-1er_firmwareimp219-1erimps110-1_firmwareibp319-1er_firmwareimp319-1er_firmwareimps110-1e_firmwareimp219-1e_firmwareimp219-1eibp219-1erimps110-1imp1110-1e_firmwareimp1110-1_firmwareimp519-1eimp319-1e_firmwareimp1110-1erimp219-1ibp219-1er_firmwareimp519-1erimp1110-1eimp319-1eibp1110-1er_firmwareibps110-1erimp219-1er_firmwareimp519-1e_firmwareimp1110-1ibp519-1erimp319-1Pelco Sarix Professional V1
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7762
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.82% / 73.45%
||
7 Day CHG~0.00%
Published-18 Apr, 2018 | 20:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.

Action-Not Available
Vendor-
Product-140cpu65160ctsxp573634mmodicon_m340_bmxp3420302h_firmware140cpu65160_firmwaretsxh5744m_firmwaremodicon_m340_bmxp342020h_firmwaretsxh5744m140cpu65160s_firmwaretsxp571634mcmodicon_m340_bmxp3420102cltsxp574634m_firmwaremodicon_m340_bmxp3420302_firmwaretsxp575634mtsxh5724mc_firmwaretsxp57304mc140cpu65860tsxp575634mc140cpu65160modicon_m340_bmxp3420302cl_firmwaretsxh5744mc_firmwaretsxp573634mc_firmwaremodicon_m340_bmxp342020_firmwaretsxp57454m_firmwaretsxp57254m_firmwaremodicon_m340_bmxp3420102_firmwaretsxp572634mtsxp57554mc_firmwaretsxp574634mtsxh5724mtsxp57304m_firmwaretsxp571634mc_firmwaretsxp57454mcmodicon_m340_bmxp341000h140cpu65160sbmxnor0200_firmwaremodicon_m340_bmxp3420302clbmxnor0200htsxp574634mc_firmwaretsxp57154mctsxp57154m_firmwaretsxp57154mtsxp576634mtsxh5744mctsxp57204mcmodicon_m340_bmxp342020140cpu31110modicon_m340_bmxp342020htsxp57354mc_firmwaretsxp57104m140cpu65150c_firmwaretsxp57354m140cpu65150_firmwaremodicon_m340_bmxp342000_firmware140cpu65860cbmxnor0200h_firmwaretsxp57204m_firmwaretsxp57204m140cpu65260tsxp571634m_firmwaretsxp573634mc140cpu43412uc140cpu65150tsxp571634mtsxp57304mc_firmware140cpu65860_firmwarebmxnor0200modicon_m340_bmxp341000h_firmware140cpu65260ctsxp57354mc140cpu65150c140cpu43412u_firmwaretsxh5724m_firmwaremodicon_m340_bmxp342000tsxp575634m_firmwaretsxp573634m_firmwaretsxp57204mc_firmwaretsxp57104mc_firmwaremodicon_m340_bmxp341000tsxh5724mc140cpu65260c_firmwaretsxp57254mc_firmware140cpu31110_firmware140cpu31110ctsxp57304mtsxp576634mcmodicon_m340_bmxp3420302htsxp574634mcmodicon_m340_bmxp3420102cl_firmwaretsxp572634mc_firmwaretsxp57454mc_firmwaretsxp576634mc_firmwaretsxp57554mctsxp575634mc_firmware140cpu65160c_firmwaretsxp576634m_firmware140cpu65260_firmwaremodicon_m340_bmxp3420302140cpu43412uc_firmwaretsxp57454mtsxp572634mcmodicon_m340_bmxp341000_firmwaretsxp57254mtsxp57104m_firmwaretsxp572634m_firmwaretsxp57554mtsxp57254mctsxp57354m_firmwaretsxp57104mctsxp57554m_firmwaremodicon_m340_bmxp3420102140cpu31110c_firmware140cpu43412utsxp57154mc_firmware140cpu65860c_firmwareModicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7796
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.3||MEDIUM
EPSS-0.28% / 51.39%
||
7 Day CHG~0.00%
Published-24 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability.

Action-Not Available
Vendor-
Product-powersuite_2PowerSuite 2, All released versions (VW3A8104 & Patches)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7851
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.33% / 55.51%
||
7 Day CHG-0.02%
Published-22 May, 2019 | 19:56
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.

Action-Not Available
Vendor-n/a
Product-bmeh584040cbmx\/e_cra_firmwarebmeh584040bmxcra31200bmeh582040c140cra312xxx_firmwaremodicon_premium_firmwaremodicon_m340_bmxp3420102clmodicon_m580_bmep583020bmxcra31210cmodicon_m580_bmep586040modicon_m580_bmep584040modicon_m340_bmxp342000modicon_m580_bmep582020modicon_m340_bmxp341000m340_firmwaremodicon_m340_bmxp3420302hmodicon_m580_bmep585040cmodicon_m580_bmep584040smodicon_m580_bmep583040modicon_m580_bmep582040modicon_m580_bmep585040modicon_m340_bmxp341000hmodicon_m580_bmep582040hmodicon_m340_bmxp3420302clbmeh586040modicon_m340_bmxp3420302modicon_premiummodicon_m580_bmep584020modicon_m580_bmep582040smodicon_m340_bmxp342020modicon_m340_bmxp342020hmodicon_m580_bmep581020modicon_m580_bmep586040cbmeh586040c140cra312xxxmodicon_m580_bmep581020hmodicon_m580_bmep582020hbmeh582040modicon_m340_bmxp3420102m580_firmwareModicon M580 with firmware prior to V2.50 Modicon M340 with firmware prior to V3.01 BMxCRA312xx with firmware prior to V2.40 All firmware versions of Modicon Premium and 140CRA312xxx
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2018-7838
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.5||HIGH
EPSS-0.37% / 57.86%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:49
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service.

Action-Not Available
Vendor-
Product-bmeh584040cmodicon_m580_bmep582040_firmwarebmeh582040_firmwarebmeh584040bmeh582040cmodicon_m580_bmep583040_firmwaremodicon_m580_bmep583020modicon_m580_bmep586040modicon_m580_bmep584040modicon_m580_bmep582020modicon_m580_bmep583020_firmwarebmeh586040_firmwaremodicon_m580_bmep585040_firmwaremodicon_m580_bmep584040_firmwaremodicon_m580_bmep585040cmodicon_m580_bmep584040smodicon_m580_bmep583040modicon_m580_bmep582040modicon_m580_bmep584020_firmwaremodicon_m580_bmep585040modicon_m580_bmep582040hbmeh586040modicon_m580_bmep584020modicon_m580_bmep582040s_firmwaremodicon_m580_bmep582040smodicon_m580_bmep581020_firmwaremodicon_m580_bmep581020modicon_m580_bmep586040cbmenoc0301_firmwarebmeh586040cmodicon_m580_bmep582020_firmwaremodicon_m580_bmep581020hmodicon_m580_bmep582020hbmeh582040bmenoc0301modicon_m580_bmep586040_firmwareModicon M580 CPU - BMEP582040 all versions before V2.90 and Modicon Ethernet Module BMENOC0301 all versions before V2.16
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2015-7937
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-4.68% / 88.90%
||
7 Day CHG~0.00%
Published-21 Dec, 2015 | 11:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m340_bmxp342030bmxnoc0401modicon_m340_bmxp3420302bmxnoe0110hbmxnoe0110bmxpra0100bmxnoe0100modicon_m340_bmxp3420302hbmxnor0200modicon_m340_bmxp342020modicon_m340_bmxp342020hbmxnoe0100hbmxnor0200hn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2015-7918
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.8||MEDIUM
EPSS-12.86% / 93.77%
||
7 Day CHG~0.00%
Published-15 Dec, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-procliman/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2015-8561
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-4.46% / 88.63%
||
7 Day CHG~0.00%
Published-15 Dec, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-procliman/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-9190
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-5.34% / 89.67%
||
7 Day CHG~0.00%
Published-10 Jan, 2015 | 02:00
Updated-24 Jul, 2025 | 22:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Schneider Electric Wonderware InTouch Access Anywhere Server Buffer Overflow

Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.

Action-Not Available
Vendor-Schneider Electric SE
Product-wonderware_intouch_access_anywhere_serverInTouch Access Anywhere Server
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-8390
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4.4||MEDIUM
EPSS-0.16% / 37.70%
||
7 Day CHG-0.01%
Published-03 Apr, 2015 | 10:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-vampsetn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-8511
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-10||HIGH
EPSS-5.35% / 89.69%
||
7 Day CHG~0.00%
Published-27 Dec, 2014 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-procliman/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-9200
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-1.47% / 80.11%
||
7 Day CHG~0.00%
Published-01 Feb, 2015 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-unity_prosomovesomove_litesomachinen/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-9206
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.9||MEDIUM
EPSS-0.05% / 13.55%
||
7 Day CHG~0.00%
Published-14 Mar, 2015 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-device_type_managern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2023-3953
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 18.91%
||
7 Day CHG~0.00%
Published-09 Aug, 2023 | 14:02
Updated-09 Oct, 2024 | 18:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause memory corruption when an authenticated user opens a tampered log file from GP-Pro EX.

Action-Not Available
Vendor-
Product-pro-face_gp-pro_exGP-Pro EX WinGP for iPCGP-Pro EX WinGP for PC/AT
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-5407
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4.4||MEDIUM
EPSS-0.05% / 15.63%
||
7 Day CHG~0.00%
Published-15 Sep, 2014 | 14:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-vampsetn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22711
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.13% / 32.71%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:23
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to missing validation of input data.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemInteractive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22705
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.06% / 18.22%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 19:19
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert

Action-Not Available
Vendor-n/a
Product-harmony_gkvijeo_designerecostruxure_machine_expertharmony_stuharmony_gtuharmony_hmiscuharmony_gtoharmony_stoharmony_gtuxHarmony HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ) or EcoStruxure Machine Expert (all versions prior to V2.0)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22712
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.13% / 32.71%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:25
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemInteractive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22761
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.22% / 44.27%
||
7 Day CHG~0.00%
Published-11 Jun, 2021 | 15:40
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) V15.0.0.21140 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22789
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.5||MEDIUM
EPSS-0.44% / 62.14%
||
7 Day CHG~0.00%
Published-02 Sep, 2021 | 16:52
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).

Action-Not Available
Vendor-n/a
Product-modicon_m580_bmeh582040modicon_premium_tsxp57_454mmodicon_mc80_bmkc8030311modicon_quantum_140cpu65160modicon_momentum_171cbu98090modicon_premium_tsxp57_1634mmodicon_m580_bmeh582040smodicon_m340_bmxp342010modicon_m580_bmep583020modicon_m580_bmeh584040smodicon_m580_bmeh586040smodicon_m580_bmep586040modicon_mc80_bmkc8020310modicon_m580_bmeh586040modicon_m580_bmep584040modicon_m580_bmep582020modicon_premium_tsxp57_2634mmodicon_quantum_140cpu65160cmodicon_m340_bmxp341000plc_simulator_for_ecostruxure_process_expertmodicon_quantum_140cpu65150cmodicon_quantum_140cpu65150modicon_m580_bmep585040cmodicon_m580_bmep584040smodicon_m580_bmeh582040cmodicon_m580_bmep583040modicon_m580_bmep582040modicon_m580_bmep585040modicon_m580_bmeh584040modicon_premium_tsxp57_4634mmodicon_m580_bmep582040hmodicon_momentum_171cbu78090modicon_premium_tsxp57_5634mmodicon_premium_tsxp57_554mmodicon_m580_bmep584020modicon_mc80_bmkc8020301modicon_m340_bmxp342020modicon_m580_bmep582040smodicon_premium_tsxp57_2834mplc_simulator_for_ecostruxure_control_expertmodicon_m580_bmep581020modicon_m580_bmep586040cmodicon_m580_bmeh586040cmodicon_momentum_171cbu98091modicon_m580_bmep581020hmodicon_m580_bmep582020hmodicon_m580_bmeh584040cmodicon_m340_bmxp342030modicon_premium_tsxp57_6634mModicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-0789
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.52% / 65.59%
||
7 Day CHG~0.00%
Published-04 Apr, 2014 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-opc_factory_server_tlxcdluofsopc_factory_server_tlxcdsuofsopc_factory_server_tlxcdlfofsopc_factory_server_tlxcdstofsopc_factory_server_tlxcdltofsn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2014-0774
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.9||MEDIUM
EPSS-0.05% / 15.03%
||
7 Day CHG~0.00%
Published-28 Feb, 2014 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-ofs_test_client_tlxcdlfofs33opc_factory_serverofs_test_client_tlxcdltofs33ofs_test_client_tlxcdsuofs33ofs_test_client_tlxcdstofs33ofs_test_client_tlxcdluofs33n/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22709
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.70% / 71.04%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:27
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemInteractive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-22714
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-2.27% / 83.98%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 20:13
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.

Action-Not Available
Vendor-n/a
Product-powerlogic_ion9000_firmwarepowerlogic_pm8000_firmwarepowerlogic_pm8000powerlogic_ion9000powerlogic_ion7400_firmwarepowerlogic_ion7400PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2017-9629
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-19.42% / 95.16%
||
7 Day CHG~0.00%
Published-07 Jul, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-wonderware_archestra_loggerSchneider Electric Wonderware ArchestrA Logger
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2013-2761
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4||MEDIUM
EPSS-0.54% / 66.57%
||
7 Day CHG~0.00%
Published-04 Apr, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service (module crash) via crafted FTP traffic, as demonstrated by the FileZilla FTP client.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_m340n/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2013-3075
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-34.69% / 96.87%
||
7 Day CHG~0.00%
Published-19 Apr, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.

Action-Not Available
Vendor-n/aSchneider Electric SEMitsubishi Electric Automation, Inc.
Product-mitsubishi_mx_componentcitectscadacitectfacilitiesn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2017-7965
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.3||HIGH
EPSS-0.08% / 25.10%
||
7 Day CHG~0.00%
Published-07 Jun, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.

Action-Not Available
Vendor-Schneider Electric SE
Product-somachine_hvacSoMachine HVAC Programming Software
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-8938
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.2||CRITICAL
EPSS-0.24% / 47.46%
||
7 Day CHG~0.00%
Published-13 Nov, 2024 | 04:20
Updated-13 Nov, 2024 | 17:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation.

Action-Not Available
Vendor-
Product-Modicon Momentum Unity M1E Processor (171CBU*)Modicon M340 CPU (part numbers BMXP34*)Modicon MC80 (part numbers BMKC80)modicon_mc80modicon_momentum_unity_m1e_processormodicon_m340
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-34764
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.9||MEDIUM
EPSS-0.59% / 68.18%
||
7 Day CHG~0.00%
Published-13 Jul, 2022 | 21:11
Updated-16 Sep, 2024 | 18:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)

Action-Not Available
Vendor-
Product-opc_ua_module_for_m580opc_ua_module_for_m580_firmwarex80_advanced_rtu_module_firmwarex80_advanced_rtu_moduleOPC UA Modicon Communication ModuleX80 advanced RTU Communication Module
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2012-0929
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-12.55% / 93.69%
||
7 Day CHG~0.00%
Published-28 Jan, 2012 | 01:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-modicon_quantum_plcn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-32512
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.58% / 67.90%
||
7 Day CHG~0.00%
Published-30 Jan, 2023 | 00:00
Updated-05 Feb, 2025 | 20:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1)

Action-Not Available
Vendor-Schneider Electric SE
Product-canbrassCanBRASS
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-7554
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 70.19%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:07
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-7550
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-7.8||HIGH
EPSS-0.66% / 70.19%
||
7 Day CHG~0.00%
Published-19 Nov, 2020 | 21:06
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

Action-Not Available
Vendor-n/a
Product-interactive_graphical_scada_systemIGSS Definition (Def.exe) version 14.0.0.20247 and prior
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2013-0658
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-69.61% / 98.59%
||
7 Day CHG~0.00%
Published-15 Feb, 2013 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-accutech_managern/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2013-0657
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-10||HIGH
EPSS-60.15% / 98.20%
||
7 Day CHG~0.00%
Published-21 Jan, 2013 | 16:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-interactive_graphical_scada_systemn/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2020-28220
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-6.8||MEDIUM
EPSS-0.28% / 50.69%
||
7 Day CHG~0.00%
Published-11 Dec, 2020 | 00:51
Updated-04 Aug, 2024 | 16:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not verified.

Action-Not Available
Vendor-n/a
Product-modicon_m258_firmwaresomachine_motionsomachinemodicon_m258Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions)
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2022-24322
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-5.3||MEDIUM
EPSS-0.22% / 44.64%
||
7 Day CHG~0.00%
Published-09 Mar, 2022 | 23:05
Updated-03 Aug, 2024 | 04:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)

Action-Not Available
Vendor-
Product-ecostruxure_control_expertEcoStruxure Control Expert
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2019-6824
Matching Score-6
Assigner-Schneider Electric
ShareView Details
Matching Score-6
Assigner-Schneider Electric
CVSS Score-9.8||CRITICAL
EPSS-13.84% / 94.04%
||
7 Day CHG~0.00%
Published-15 Jul, 2019 | 20:44
Updated-04 Aug, 2024 | 20:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

Action-Not Available
Vendor-Schneider Electric SE
Product-proclimaProClima all versions prior to version 8.0.0
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2011-5163
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4.6||MEDIUM
EPSS-0.17% / 38.08%
||
7 Day CHG~0.00%
Published-15 Sep, 2012 | 17:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.

Action-Not Available
Vendor-n/aMitsubishi Electric Automation, Inc.Schneider Electric SE
Product-mx4_scadacitectscadan/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2011-4033
Matching Score-6
Assigner-CERT/CC
ShareView Details
Matching Score-6
Assigner-CERT/CC
CVSS Score-4.3||MEDIUM
EPSS-0.56% / 67.25%
||
7 Day CHG~0.00%
Published-02 Dec, 2011 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-vijeo_historiancitectscada_reportscitecthistoriann/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2011-4034
Matching Score-6
Assigner-CERT/CC
ShareView Details
Matching Score-6
Assigner-CERT/CC
CVSS Score-9.3||HIGH
EPSS-4.42% / 88.59%
||
7 Day CHG~0.00%
Published-02 Dec, 2011 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors.

Action-Not Available
Vendor-n/aSchneider Electric SE
Product-vijeo_historiancitectscada_reportscitecthistoriann/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer