Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request.
The Siemens SPCanywhere application for Android and iOS does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
node-fetch is vulnerable to Exposure of Sensitive Information to an Unauthorized Actor
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit.
OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h does not properly restrict processing of ChangeCipherSpec messages, which allows man-in-the-middle attackers to trigger use of a zero-length master key in certain OpenSSL-to-OpenSSL communications, and consequently hijack sessions or obtain sensitive information, via a crafted TLS handshake, aka the "CCS Injection" vulnerability.
A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.
A vulnerability has been identified in Desigo Insight (All versions). The device does not properly set the X-Frame-Options HTTP Header which makes it vulnerable to Clickjacking attacks. This could allow an unauthenticated attacker to retrieve or modify data in the context of a legitimate user by tricking that user to click on a website controlled by the attacker.
A vulnerability has been identified in Polarion Subversion Webclient (All versions). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application.
A vulnerability has been identified in Siveillance VMS Video for Android (All versions < V12.1a (2018 R1)), Siveillance VMS Video for iOS (All versions < V12.1a (2018 R1)). Improper certificate validation could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. The security vulnerability could be exploited by an attacker in a privileged network position which allows intercepting the communication channel between the affected app and a server (such as Man-in-the-Middle). Furthermore, an attacker must be able to generate a certificate that results for the validation algorithm in a checksum identical to a trusted certificate. Successful exploitation requires no user interaction. The vulnerability could allow reading data from and writing data to the encrypted communication channel between the app and a server, impacting the communication's confidentiality and integrity. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp.
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack.
A vulnerability has been identified in SINUMERIK Edge (All versions < V3.2). The affected software does not properly validate the server certificate when initiating a TLS connection. This could allow an attacker to spoof a trusted entity by interfering in the communication path between the client and the intended server.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic.
The Siemens COMPAS Mobile application before 1.6 for Android does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.
An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method.
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack.
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.1.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.1.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.1.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.1.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.1.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.1.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.1.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.1.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.1.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.1.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.1.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.1.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.1.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.1.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.1.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.1.2), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions >= V1.1.0 < V3.0.0). Affected devices with TCP Event service enabled do not properly handle malformed packets. This could allow an unauthenticated remote attacker to cause a denial of service condition and reboot the device thus possibly affecting other network resources.
Improper input validation in BIOS firmware for some Intel(R) Processors may allow an authenticated user to potentially enable escalation of privilege via local access.
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly validate parameters of POST requests. This could allow an authenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device.
The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). Affected devices do not properly handle malformed HTTP packets. This could allow an unauthenticated remote attacker to send a malformed HTTP packet causing certain functions to fail in a controlled manner.
An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface.
A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed Multicast LLC frames. This could allow an attacker to trigger a denial of service condition.
A vulnerability has been identified in SiPass integrated (All versions < V2.90.3.8). Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow. This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition.
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V2.85.44), SiPass integrated ACC-AP (All versions < V2.85.43). Affected devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges.
The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0143, CVE-2017-0144, CVE-2017-0145, and CVE-2017-0146.
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system.
A vulnerability has been identified in SCALANCE W1788-1 M12 (All versions < V3.0.0), SCALANCE W1788-2 EEC M12 (All versions < V3.0.0), SCALANCE W1788-2 M12 (All versions < V3.0.0), SCALANCE W1788-2IA M12 (All versions < V3.0.0). Affected devices do not properly handle malformed TCP packets received over the RemoteCapture feature. This could allow an attacker to lead to a denial of service condition which only affects the port used by the RemoteCapture feature.
In Network Security Services (NSS) before 3.46, several cryptographic primitives had missing length checks. In cases where the application calling the library did not perform a sanity check on the inputs it could result in a crash due to a buffer overflow.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices.
The web server on Siemens SCALANCE X-200IRT switches with firmware before 5.2.0 allows remote attackers to hijack sessions via unspecified vectors.
Siemens SPC controllers SPC4000, SPC5000, and SPC6000 before 3.6.0 allow remote attackers to cause a denial of service (device restart) via crafted packets.
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects.
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow an remote attacker to trigger a denial of service of the affected system.
A vulnerability has been identified in SIMATIC TDC CP51M1 (All versions < V1.1.7). An attacker with network access to the device could cause a Denial-of-Service condition by sending a specially crafted UDP packet. The vulnerability affects the UDP communication of the device. The security vulnerability could be exploited without authentication. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition.
Siemens SINEMA Server before 12 SP1 allows remote attackers to cause a denial of service (web-interface outage) via crafted HTTP requests to port (1) 4999 or (2) 80.
A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions < V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Received webpackets are not properly processed. An unauthenticated remote attacker with access to any of the Ethernet interfaces could send specially crafted packets to force a restart of the target device.
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize input for the pubkey endpoint of the REST API. This could allow an authenticated remote administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges.
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize user input for specific commands on the telnet command line interface. This could allow an authenticated local administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges.
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13351)