A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.
node-fetch is vulnerable to Exposure of Sensitive Information to an Unauthorized Actor
A vulnerability has been identified in Siveillance VMS Video for Android (All versions < V12.1a (2018 R1)), Siveillance VMS Video for iOS (All versions < V12.1a (2018 R1)). Improper certificate validation could allow an attacker in a privileged network position to read data from and write data to the encrypted communication channel between the app and a server. The security vulnerability could be exploited by an attacker in a privileged network position which allows intercepting the communication channel between the affected app and a server (such as Man-in-the-Middle). Furthermore, an attacker must be able to generate a certificate that results for the validation algorithm in a checksum identical to a trusted certificate. Successful exploitation requires no user interaction. The vulnerability could allow reading data from and writing data to the encrypted communication channel between the app and a server, impacting the communication's confidentiality and integrity. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.
OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h does not properly restrict processing of ChangeCipherSpec messages, which allows man-in-the-middle attackers to trigger use of a zero-length master key in certain OpenSSL-to-OpenSSL communications, and consequently hijack sessions or obtain sensitive information, via a crafted TLS handshake, aka the "CCS Injection" vulnerability.
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.
Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack.
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp.
Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request.
A vulnerability has been identified in SINUMERIK Edge (All versions < V3.2). The affected software does not properly validate the server certificate when initiating a TLS connection. This could allow an attacker to spoof a trusted entity by interfering in the communication path between the client and the intended server.
A vulnerability has been identified in Polarion Subversion Webclient (All versions). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application.
An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method.
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic.
A vulnerability has been identified in XHQ (All versions < V6.0.0.2). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security vulnerability was known.
The Siemens SPCanywhere application for Android and iOS does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.
A vulnerability has been identified in Desigo Insight (All versions). The device does not properly set the X-Frame-Options HTTP Header which makes it vulnerable to Clickjacking attacks. This could allow an unauthenticated attacker to retrieve or modify data in the context of a legitimate user by tricking that user to click on a website controlled by the attacker.
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack.
The Siemens COMPAS Mobile application before 1.6 for Android does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.
Drupal versions 5.x and 6.x has open redirection
Missing custom error page vulnerability in Synology Web Station before 2.1.3-0139 allows remote attackers to conduct phishing attacks via a crafted URL.
Opera Mini 13 and Opera Stable 36 allow remote attackers to spoof the displayed URL via a crafted HTML document, related to the about:blank URL.
A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced Reports and Dashboards Module, EcoStruxure Power Monitoring Expert (PME) v9.0, EcoStruxure Energy Expert v2.0, and EcoStruxure Power SCADA Operation (PSO) 9.0 Advanced Reports and Dashboards Module which could cause a phishing attack when redirected to a malicious site.
A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing.
Gitpod before 0.6.0 allows unvalidated redirects.
TYPO3 before 4.1.14, 4.2.x before 4.2.13, 4.3.x before 4.3.4 and 4.4.x before 4.4.1 allows Open Redirection on the backend.
It was found in vanilla forums before 2.0.10 a potential linkbait vulnerability in dispatcher.
Zabbix before 2.2.21rc1, 3.x before 3.0.13rc1, 3.1.x and 3.2.x before 3.2.10rc1, and 3.3.x and 3.4.x before 3.4.4rc1 allows open redirect via the request parameter.
F-Secure Radar (on-premises) before 2018-02-15 has an Unvalidated Redirect via the ReturnUrl parameter that triggers upon a user login.
An issue was discovered in Open-AudIT Professional 2.1. It is possible to inject a malicious payload in the redirect_url parameter to the /login URI to trigger an open redirect. A "data:text/html;base64," payload can be used with JavaScript code.
On BIG-IP APM 11.6.0-11.6.3, an insecure AES ECB mode is used for orig_uri parameter in an undisclosed /vdesk link of APM virtual server configured with an access profile, allowing a malicious user to build a redirect URI value using different blocks of cipher texts.
cPanel before 60.0.25 allows an open redirect via /cgi-sys/FormMail-clone.cgi (SEC-162).
The CGIHandler class in Python before 2.7.12 does not protect against the HTTP_PROXY variable name clash in a CGI script, which could allow a remote attacker to redirect HTTP requests.
Jensen of Scandinavia AS Air:Link 3G (AL3G) version 2.23m (Rev. 3), Air:Link 5000AC (AL5000AC) version 1.13, and Air:Link 59300 (AL59300) version 1.04 (Rev. 4) devices allow remote attackers to conduct Open Redirect attacks via the return-url parameter to /goform/formLogout.
The Nested Pages WordPress plugin <= 3.1.15 was vulnerable to an Open Redirect via the `page` POST parameter in the `npBulkActions`, `npBulkEdit`, `npListingSort`, and `npCategoryFilter` `admin_post` actions.
HPE XP P9000 Command View Advanced Edition Software (CVAE) has open URL redirection vulnerability in versions 7.0.0-00 to earlier than 8.60-00 of DevMgr, TSMgr and RepMgr.
Multiple open redirect vulnerabilities in Pivotal Cloud Foundry (PCF) Elastic Runtime before 1.6.30 and 1.7.x before 1.7.8 allow remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors.
SimpleSAMLphp before 1.15.2 allows remote attackers to bypass an open redirect protection mechanism via crafted authority data in a URL.
Kibana versions before 4.6.3 and 5.0.1 have an open redirect vulnerability that would enable an attacker to craft a link in the Kibana domain that redirects to an arbitrary website.
An open redirect vulnerability has been reported to affect QNAP device running QcalAgent. If exploited, this vulnerability allows attackers to redirect users to an untrusted page that contains malware. We have already fixed this vulnerability in the following versions of QcalAgent: QcalAgent 1.1.7 and later
mod_auth_openidc is an authentication/authorization module for the Apache 2.x HTTP server that functions as an OpenID Connect Relying Party, authenticating users against an OpenID Connect Provider. In versions prior to 2.4.9.4, the 3rd-party init SSO functionality of mod_auth_openidc was reported to be vulnerable to an open redirect attack by supplying a crafted URL in the `target_link_uri` parameter. A patch in version 2.4.9.4 made it so that the `OIDCRedirectURLsAllowed` setting must be applied to the `target_link_uri` parameter. There are no known workarounds aside from upgrading to a patched version.
The fix in Kibana for ESA-2017-23 was incomplete. With X-Pack security enabled, Kibana versions before 6.1.3 and 5.6.7 have an open redirect vulnerability on the login page that would enable an attacker to craft a link that redirects to an arbitrary website.
inets in Erlang possibly 22.1 and earlier follows RFC 3875 section 4.1.18 and therefore does not protect applications from the presence of untrusted client data in the HTTP_PROXY environment variable, which might allow remote attackers to redirect an application's outbound HTTP traffic to an arbitrary proxy server via a crafted Proxy header in an HTTP request, aka an "httpoxy" issue.
Open redirect in hekto <=0.2.3 when target domain name is used as html filename on server.
The NetIQ Identity Manager user console, in versions prior to 4.7, is susceptible to URL redirection.
Open redirect vulnerability in Opsview Monitor Pro (Prior to 5.1.0.162300841, prior to 5.0.2.27475, prior to 4.6.4.162391051, and 4.5.x without a certain 2016 security patch) allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via the back parameter to the /login URI.
yaws before 2.0.4 does not attempt to address RFC 3875 section 4.1.18 namespace conflicts and therefore does not protect CGI applications from the presence of untrusted client data in the HTTP_PROXY environment variable, which might allow remote attackers to redirect a CGI application's outbound HTTP traffic to an arbitrary proxy server via a crafted Proxy header in an HTTP request, aka an "httpoxy" issue.
Unvalidated redirect vulnerability in in NetIQ eDirectory before 9.1.1 HF1.
Due to insufficient URL Validation in forums in SAP NetWeaver versions 7.30, 7.31, 7.40, an attacker can redirect users to a malicious site.