Roxy-WI is a web interface for managing Haproxy, Nginx, Apache and Keepalived servers. Versions prior to 6.1.1.0 are subject to a remote code execution vulnerability. System commands can be run remotely via the subprocess_execute function without processing the inputs received from the user in the /app/options.py file. Attackers need not be authenticated to exploit this vulnerability. Users are advised to upgrade. There are no known workarounds for this vulnerability.
HooToo TripMate Titan HT-TM05 and HT-05 routers with firmware 2.000.022 and 2.000.082 allow remote command execution via shell metacharacters in the mac parameter of a protocol.csp?function=set&fname=security&opt=mac_table request.
An issue was discovered on Fujitsu ETERNUS CentricStor CS8000 (Control Center) devices before 8.1A SP02 P04. The vulnerability resides in the requestTempFile function in hw_view.php. An attacker is able to influence the unitName POST parameter and inject special characters such as semicolons, backticks, or command-substitution sequences in order to force the application to execute arbitrary commands.
Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac.
In Visual Tools DVR VX16 4.2.28.0, an unauthenticated attacker can achieve remote command execution via shell metacharacters in the cgi-bin/slogin/login.py User-Agent HTTP header.
KLog Server 2.4.1 allows OS command injection via shell metacharacters in the actions/authenticate.php user parameter.
An issue was discovered in ClusterLabs Hawk 2.x through 2.3.0-x. There is a Ruby shell code injection issue via the hawk_remember_me_id parameter in the login_from_cookie cookie. The user logout routine could be used by unauthenticated remote attackers to execute code as hauser.
HGiga MailSherlock does not validate specific parameters properly. Attackers can use the vulnerability to launch Command inject attacks remotely and execute arbitrary commands of the system.
An unauthenticated command-execution vulnerability exists in TerraMaster TOS through 4.2.06 via shell metacharacters in the Event parameter in include/makecvs.php during CSV creation.
An issue in adm.cgi of WAVLINK AERIAL X 1200M M79X3.V5030.180719 allows attackers to execute arbitrary commands via a crafted POST request.
An issue was discovered on Fujitsu ETERNUS CentricStor CS8000 (Control Center) devices before 8.1A SP02 P04. The vulnerability resides in the grel_finfo function in grel.php. An attacker is able to influence the username (user), password (pw), and file-name (file) parameters and inject special characters such as semicolons, backticks, or command-substitution sequences in order to force the application to execute arbitrary commands.
An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. The login form passes user input directly to a shell command without any kind of escaping or validation in /usr/share/www/check.lp file. An attacker is able to perform command injection using the "password" parameter in the login form.
A vulnerability in the web-based management interface of Cisco DNA Spaces Connector could allow an unauthenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient validation of user-supplied input in the web-based management interface. An attacker could exploit this vulnerability by sending crafted HTTP requests to the web-based management interface. A successful exploit could allow the attacker to execute arbitrary commands on the underling operating system with privileges of the web-based management application, which is running as a restricted user. This could result in changes being made to pages served by the web-based management application impacting the integrity or availability of the web-based management application.
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-on" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
An issue was discovered in Radisys MRF Web Panel (SWMS) 9.0.1. The MSM_MACRO_NAME POST parameter in /swms/ms.cgi was discovered to be vulnerable to OS command injection attacks. It is possible to use the pipe character (|) to inject arbitrary OS commands and retrieve the output in the application's responses. Attackers could execute unauthorized commands, which could then be used to disable the software, or read, write, and modify data for which the attacker does not have permissions to access directly. Since the targeted application is directly executing the commands instead of the attacker, any malicious activities may appear to come from the application or the application's owner (apache user).
In the /HNAP1/SetWiFiVerifyAlpha message, the WPSPIN parameter is vulnerable, and the vulnerability affects D-Link DIR-822 B1 202KRb06 devices. In the SetWiFiVerifyAlpha.php source code, the WPSPIN parameter is saved in the $rphyinf1."/media/wps/enrollee/pin" and $rphyinf2."/media/wps/enrollee/pin" and $rphyinf3."/media/wps/enrollee/pin" internal configuration memory without any regex checking. And in the do_wps function of the wps.php source code, the data in $rphyinf3."/media/wps/enrollee/pin" is used with the wpatalk command without any regex checking. A vulnerable /HNAP1/SetWiFiVerifyAlpha XML message could have shell metacharacters in the WPSPIN element such as the `telnetd` string.
DELL EMC Avamar Server, versions 19.1, 19.2, 19.3, contain an OS Command Injection Vulnerability in Fitness Analyzer. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS with high privileges. This vulnerability is considered critical as it can be leveraged to completely compromise the vulnerable application as well as the underlying operating system. Dell recommends customers to upgrade at the earliest opportunity.
Command Injection in TOTOLINK X5000R router with firmware v9.1.0u.6118_B20201102, and TOTOLINK A720R router with firmware v4.1.5cu.470_B20200911 allows remote attackers to execute arbitrary OS commands by sending a modified HTTP request. This occurs because the function executes glibc's system function with untrusted input. In the function, "ip" parameter is directly passed to the attacker, allowing them to control the "ip" field to attack the OS.
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. Command injection can occur in "upload tftp syslog" and "upload tftp configuration" in the CLI via a crafted filename.
An exploitable unatuhenticated command injection exists in the OpenClinic GA 5.173.3. Specially crafted web requests can cause commands to be executed on the server. An attacker can send a web request with parameters containing specific parameter to trigger this vulnerability, potentially allowing exfiltration of the database, user credentials and compromise underlying operating system.
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
osCommerce Phoenix CE before 1.0.5.4 allows OS command injection remotely. Within admin/mail.php, a from POST parameter can be passed to the application. This affects the PHP mail function, and the sendmail -f option.
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-off" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
A OS command injection vulnerability in the CGI program of Zyxel USG FLEX 100(W) firmware versions 5.00 through 5.21 Patch 1, USG FLEX 200 firmware versions 5.00 through 5.21 Patch 1, USG FLEX 500 firmware versions 5.00 through 5.21 Patch 1, USG FLEX 700 firmware versions 5.00 through 5.21 Patch 1, USG FLEX 50(W) firmware versions 5.10 through 5.21 Patch 1, USG20(W)-VPN firmware versions 5.10 through 5.21 Patch 1, ATP series firmware versions 5.10 through 5.21 Patch 1, VPN series firmware versions 4.60 through 5.21 Patch 1, which could allow an attacker to modify specific files and then execute some OS commands on a vulnerable device.
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the webwlanidx parameter in /setting/setWebWlanIdx.
D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a command injection vulnerability via the admuser and admpass parameters in /goform/setSysAdm.
The Data Protection extension in the VMware GUI in IBM Tivoli Storage Manager for Virtual Environments: Data Protection for VMware (aka Spectrum Protect for Virtual Environments) 7.1 before 7.1.3.0 and Tivoli Storage FlashCopy Manager for VMware (aka Spectrum Protect Snapshot) 4.1 before 4.1.3.0 allows remote attackers to execute arbitrary OS commands via unspecified vectors.
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the filename parameter in /setting/setUpgradeFW.
Exposed Erlang Cookie could lead to Remote Command Execution (RCE) attack. Communication between Erlang nodes is done by exchanging a shared secret (aka "magic cookie"). There are cases where the magic cookie is included in the content of the logs. An attacker can use the cookie to attach to an Erlang node and run OS level commands on the system running the Erlang node. Affects version: 6.5.1. Fix version: 6.6.0.
The Web Console in Commvault Edge Server 10 R2 allows remote attackers to execute arbitrary OS commands via crafted serialized data in a cookie.
CGI implementation in Yaws web server versions 1.81 to 2.0.7 is vulnerable to OS command injection.
A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aruba Instant 8.7.x: 8.7.0.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
A remote code execution vulnerability exists in the WebAdmin of Sophos SG UTM before v9.705 MR5, v9.607 MR7, and v9.511 MR11
im-resize through 2.3.2 allows remote attackers to execute arbitrary commands via the "exec" argument. The cmd argument used within index.js, can be controlled by user without any sanitization.
The administration console of the Moog EXO Series EXVF5C-2 and EXVP7C2-3 units features a 'statusbroadcast' command that can spawn a given process repeatedly at a certain time interval as 'root'. One of the limitations of this feature is that it only takes a path to a binary without arguments; however, this can be circumvented using special shell variables, such as '${IFS}'. As a result, an attacker can execute arbitrary commands as 'root' on the units.
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the langtype parameter in /setting/setLanguageCfg.
SolarView Compact ver.6.00 was discovered to contain a command injection vulnerability via conf_mail.php.
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the hosttime function in /setting/NTPSyncWithHost.
A command injection vulnerability in the component /setnetworksettings/IPAddress of D-Link DIR882 DIR882A1_FW130B06 allows attackers to escalate privileges to root via a crafted payload.
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the devicename parameter in /setting/setDeviceName.
An command injection vulnerability in HNAP1/SetWLanApcliSettings of Motorola CX2 router CX 1.0.2 Build 20190508 Rel.97360n allows attackers to execute arbitrary system commands.
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the filename parameter in /setting/CloudACMunualUpdate.
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the filename parameter in /setting/setUploadSetting.
A command injection vulnerability in the component /SetTriggerLEDBlink/Blink of D-Link DIR882 DIR882A1_FW130B06 allows attackers to escalate privileges to root via a crafted payload.
An unspecified CGI script in Cisco FX-OS before 1.1.2 on Firepower 9000 devices and Cisco Unified Computing System (UCS) Manager before 2.2(4b), 2.2(5) before 2.2(5a), and 3.0 before 3.0(2e) allows remote attackers to execute arbitrary shell commands via a crafted HTTP request, aka Bug ID CSCur90888.
A remote command execution vulnerability exists in add_server_service of PPTP_SERVER in Mercury Router MER1200 v1.0.1 and Mercury Router MER1200G v1.0.1.
In Apache SpamAssassin before 3.4.5, malicious rule configuration (.cf) files can be configured to run system commands without any output or errors. With this, exploits can be injected in a number of scenarios. In addition to upgrading to SA version 3.4.5, users should only use update channels or 3rd party .cf files from trusted places.
TOTOLink N600R V5.3c.7159_B20190425 was discovered to contain a command injection vulnerability via the ipdoamin parameter in /setting/setDiagnosisCfg.
Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/exeCommand.