An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
Taiwan Secom Dr.ID Access Control system’s login page has a hard-coded credential in the source code. An unauthenticated remote attacker can use the hard-coded credential to acquire partial system information and modify system setting to cause partial disrupt of service.
ZyXEL ZyWALL 1050 has a hard-coded password for the Quagga and Zebra processes that is not changed when it is set by a user, which allows remote attackers to gain privileges.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00
Home Owners Collection Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel.
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. We have confirmed this flaw in MiR100 and MiR200 but it might also apply to MiR250, MiR500 and MiR1000.
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as very critical, has been found in D-Link DNS-320L, DNS-325, DNS-327L and DNS-340L up to 20240403. This issue affects some unknown processing of the file /cgi-bin/nas_sharing.cgi of the component HTTP GET Request Handler. The manipulation of the argument user with the input messagebus leads to hard-coded credentials. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-259283. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
Databasir is a team-oriented relational database model document management platform. Databasir 1.01 has Use of Hard-coded Cryptographic Key vulnerability. An attacker can use hard coding to generate login credentials of any user and log in to the service background located at different IP addresses.
WAC on the Sangfor Sundray WLAN Controller version 3.7.4.2 and earlier has a backdoor account allowing a remote attacker to login to the system via SSH (on TCP port 22345) and escalate to root (because the password for root is the WebUI admin password concatenated with a static string).
By default, BMC PATROL Agent through 11.3.01 uses a static encryption key for encrypting/decrypting user credentials sent over the network to managed PATROL Agent services. If an attacker were able to capture this network traffic, they could decrypt these credentials and use them to execute code or escalate privileges on the network.
The backdoor account dnsekakf2$$ in /bin/login on DASAN H665 devices with firmware 1.46p1-0028 allows an attacker to login to the admin account via TELNET.
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.
An issue was discovered in TitanFTP (aka Titan FTP) NextGen before 1.2.1050. There is Remote Code Execution due to a hardcoded password for the sa account on the Microsoft SQL Express 2019 instance installed by default during TitanFTP NextGen installation, aka NX-I674 (sub-issue 1). NOTE: as of 2022-06-21, the 1.2.1050 release corrects this vulnerability in a new installation, but not in an upgrade installation.
The rpWLANRedirect.asp ASP page is accessible without authentication on ZyXEL P-660HN-T1 V2 (2.00(AAKK.3)) devices. After accessing the page, the admin user's password can be obtained by viewing the HTML source code, and the interface of the modem can be accessed as admin.
Use of Hard-coded Credentials vulnerability in FortiRecorder all versions below 2.7.4 may allow an unauthenticated attacker with knowledge of the aforementioned credentials and network access to FortiCameras to take control of those, provided they are managed by a FortiRecorder device.
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials.
IBM Security Guardium Data Encryption (GDE) 3.0.0.2 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 171832.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
admin.php in SmartSiteCMS 1.0 allows remote attackers to bypass authentication and gain administrator privileges by setting the userName cookie.
FreeSWITCH 1.6.10 through 1.10.1 has a default password in event_socket.conf.xml.
Use of hard-coded cryptographic key vulnerability in QSAN Storage Manager allows attackers to obtain users’ credentials and related permissions. Suggest contacting with QSAN and refer to recommendations in QSAN Document.
An issue was discovered in TitanHQ WebTitan before 5.18. It has a hidden support account (with a hard-coded password) in the web administration interface, with administrator privileges. Anybody can log in with this account.
QXIP SIPCAPTURE homer-app before 1.4.28 for HOMER 7.x has the same 167f0db2-f83e-4baa-9736-d56064a5b415 JWT secret key across different customers' installations.
An authentication weakness in the SNMP service in B&R Automation Runtime versions 2.96, 3.00, 3.01, 3.06 to 3.10, 4.00 to 4.63, 4.72 and above allows unauthenticated users to modify the configuration of B&R products via SNMP.
Trend Micro ServerProtect 6.0/5.8 Information Server uses a static credential to perform authentication when a specific command is typed in the console. An unauthenticated remote attacker with access to the Information Server could exploit this to register to the server and perform authenticated actions.
A vulnerability in the Cisco Common Services Platform Collector (CSPC) could allow an unauthenticated, remote attacker to access an affected device by using an account that has a default, static password. This account does not have administrator privileges. The vulnerability exists because the affected software has a user account with a default, static password. An attacker could exploit this vulnerability by remotely connecting to the affected system using this account. A successful exploit could allow the attacker to log in to the CSPC using the default account. For Cisco CSPC 2.7.x, Cisco fixed this vulnerability in Release 2.7.4.6. For Cisco CSPC 2.8.x, Cisco fixed this vulnerability in Release 2.8.1.2.
Black Box iCOMPEL 9.2.3 through 11.1.4, as used in ONELAN Net-Top-Box 9.2.3 through 11.1.4 and other products, has default credentials that allow remote attackers to access devices remotely via SSH, HTTP, HTTPS, and FTP.
NETGEAR XR1000 devices before 1.0.0.58 are affected by a hardcoded password.
WAGO 852-303 before FW06, 852-1305 before FW06, and 852-1505 before FW03 devices contain hardcoded users and passwords that can be used to login via SSH and TELNET.
WAGO 852-303 before FW06, 852-1305 before FW06, and 852-1505 before FW03 devices contain hardcoded private keys for the SSH daemon. The fingerprint of the SSH host key from the corresponding SSH daemon matches the embedded private key.
Arkeia Network Backup Client 5.x contains hard-coded credentials that effectively serve as a back door, which allows remote attackers to access the file system and possibly execute arbitrary commands.
Hardcoded credentials in the Akuvox R50P VoIP phone 50.0.6.156 allow an attacker to get access to the device via telnet. The telnet service is running on port 2323; it cannot be turned off and the credentials cannot be changed.
An issue was discovered in Kaseya Unitrends Backup Appliance before 10.5.5. The SNMP daemon was configured with a weak default community.
Computrols CBAS 18.0.0 has Default Credentials.
An issue was discovered on Glory RBW-100 devices with firmware ISP-K05-02 7.0.0. A hard-coded username and password were identified that allow a remote attacker to gain admin access to the Front Circle Controller web interface.
The express install, which is the suggested way to install Puppet Enterprise, gives the user a URL at the end of the install to set the admin password. If they do not use that URL, there is an overlooked default password for the admin user. This was resolved in Puppet Enterprise 2019.0.3 and 2018.1.9.
A vulnerability in Antminer Monitor 0.50.0 exists because of backdoor or misconfiguration inside a settings file in flask server. Settings file has a predefined secret string, which would be randomly generated, however it is static.
An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A specially-crafted HTTP request can lead to unauthorized access. An attacker can send an HTTP request to trigger this vulnerability.
The Web-GUI on WAGO Series 750-88x (750-330, 750-352, 750-829, 750-831, 750-852, 750-880, 750-881, 750-882, 750-884, 750-885, 750-889) and Series 750-87x (750-830, 750-849, 750-871, 750-872, 750-873) devices has undocumented service access.
SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
A use of hard-coded password vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to gain access through accounts using default passwords
A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has been published and may be used. Upgrading to version 5.7.1 is sufficient to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
A vulnerability in the web-based management interface of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. The vulnerability is due to improper session management on affected DCNM software. An attacker could exploit this vulnerability by sending a crafted HTTP request to the affected device. A successful exploit could allow the attacker to gain administrative access on the affected device.
ICS/StaticPages/AddTestUsers.aspx in Jenzabar JICS (aka Internet Campus Solution) before 2019-02-06 allows remote attackers to create an arbitrary number of accounts with a password of 1234.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.