Multiple vulnerabilities in the authentication mechanisms of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. For more information about these vulnerabilities, see the Details section of this advisory.
TELESTAR Bobs Rock Radio, Dabman D10, Dabman i30 Stereo, Imperial i110, Imperial i150, Imperial i200, Imperial i200-cd, Imperial i400, Imperial i450, Imperial i500-bt, and Imperial i600 TN81HH96-g102h-g102 devices have an undocumented TELNET service within the BusyBox subsystem, leading to root access.
WolfVision Cynap before 1.30j uses a static, hard-coded cryptographic secret for generating support PINs for the 'forgot password' feature. By knowing this static secret and the corresponding algorithm for calculating support PINs, an attacker can reset the ADMIN password and thus gain remote access.
Hardcoded credentials in the Akuvox R50P VoIP phone 50.0.6.156 allow an attacker to get access to the device via telnet. The telnet service is running on port 2323; it cannot be turned off and the credentials cannot be changed.
Mirasys VMS before V7.6.1 and 8.x before V8.3.2 mishandles the Mirasys.Common.Utils.Security.DataCrypt method in Common.dll in AuditTrailService in SMServer.exe. This method triggers insecure deserialization within the .NET garbage collector, in which a gadget (contained in a serialized object) may be executed with SYSTEM privileges. The attacker must properly encrypt the object; however, the hardcoded keys are available.
An issue was discovered on Glory RBW-100 devices with firmware ISP-K05-02 7.0.0. A hard-coded username and password were identified that allow a remote attacker to gain admin access to the Front Circle Controller web interface.
ICS/StaticPages/AddTestUsers.aspx in Jenzabar JICS (aka Internet Campus Solution) before 2019-02-06 allows remote attackers to create an arbitrary number of accounts with a password of 1234.
A low privileged admin account with a weak default password of admin exists on the Foxconn FEMTO AP-FC4064-T AP_GT_B38_5.8.3lb15-W47 LTE Build 15. In addition, its web management page relies on the existence or values of cookies when performing security-critical operations. One can gain privileges by modifying cookies.
Prisma Industriale Checkweigher PrismaWEB 1.21 allows remote attackers to discover the hardcoded prisma password for the prismaweb account by reading user/scripts/login_par.js.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
REINER timeCard 6.05.07 installs a Microsoft SQL Server with an sa password that is hardcoded in the TCServer.jar file.
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices have a hardcoded password of admin for the admin account, a hardcoded password of support for the support account, and a hardcoded password of user for the user account.
An issue was discovered in the MBeans Server in Wowza Streaming Engine before 4.7.1. The file system may be read and written to via JMX using the default JMX credentials (remote code execution may be possible as well).
In the web server on D-Link DIR-620 devices with a certain customized (by ISP) variant of firmware 1.0.3, 1.0.37, 1.3.1, 1.3.3, 1.3.7, 1.4.0, and 2.0.22, there is a hardcoded password of anonymous for the admin account.
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
D-Link COVR-2600R and COVR-3902 Kit before 1.01b05Beta01 use hardcoded credentials for telnet connection, which allows unauthenticated attackers to gain privileged access to the router, and to extract sensitive data or modify the configuration.
A vulnerability classified as critical has been found in TOTOLINK T10 AC1200 4.1.8cu.5207. Affected is an unknown function of the file /squashfs-root/web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Linear eMerge E3-Series devices allow Remote Code Execution (root access over SSH).
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A hard-coded account allows management-interface login with high privileges. The logged-in user can perform critical tasks and take full control of the device.
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller.
SAP Commerce, versions - 6.7, 1808, 1811, 1905, and SAP Commerce (Data Hub), versions - 6.7, 1808, 1811, 1905, allows an attacker to bypass the authentication and/or authorization that has been configured by the system administrator due to the use of Hardcoded Credentials.
GeoVision Door Access Control device family is hardcoded with a root password, which adopting an identical password in all devices.
Hard-coded FTP credentials (r:r) are included in the Foscam C1 running firmware 1.9.1.12. Knowledge of these credentials would allow remote access to any cameras found on the internet that do not have port 50021 blocked by an intermediate device.
Axesstel MU553S MU55XS-V1.14 devices have a default password of admin for the admin account.