Stack-based buffer overflow in BMC PATROL Agent Service Daemon for in Performance Analysis for Servers, Performance Assurance for Servers, and Performance Assurance for Virtual Servers 7.4.00 through 7.5.10; Performance Analyzer and Performance Predictor for Servers 7.4.00 through 7.5.10; and Capacity Management Essentials 1.2.00 (7.4.15) allows remote attackers to execute arbitrary code via a crafted length value in a BGS_MULTIPLE_READS command to TCP port 6768.
BMC Track-It! 11.4 before Hotfix 3 exposes an unauthenticated .NET remoting configuration service (ConfigurationService) on port 9010. This service contains a method that can be used to retrieve a configuration file that contains the application database name, username and password as well as the domain administrator username and password. These are encrypted with a fixed key and IV ("NumaraIT") using the DES algorithm. The domain administrator username and password can only be obtained if the Self-Service component is enabled, which is the most common scenario in enterprise deployments.
BMC BladeLogic Server Automation (BSA) before 8.7 Patch 3 allows remote attackers to bypass authentication and consequently read arbitrary files or possibly have unspecified other impact by leveraging a "logic flaw" in the authentication process.
BMC Patrol allows remote attackers to gain access to an agent by spoofing frames.
Format string vulnerability in BMC PATROL Agent before 3.7.30 allows remote attackers to execute arbitrary code via format string specifiers in an invalid version number to TCP port 3181, which are not properly handled when writing a log message.
Patrol management software allows a remote attacker to conduct a replay attack to steal the administrator password.
The RPC API in the RSCD agent in BMC BladeLogic Server Automation (BSA) 8.2.x, 8.3.x, 8.5.x, 8.6.x, and 8.7.x on Linux and UNIX allows remote attackers to bypass authorization and reset arbitrary user passwords by sending an action packet to xmlrpc after an authorization failure.
An issue was discovered in BMC Control-M/MFT 9.0.20 through 9.0.22. An API management endpoint allows unauthenticated users to obtain both an API identifier and its corresponding secret value. With these exposed secrets, an attacker could invoke privileged API operations, potentially leading to unauthorized access.
IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.
eClass platform < ip.2.5.10.2.1 allows an attacker to use GETS method to request /admin page to bypass the password validation and access management page.
The web application portal of the Cobham EXPLORER 710, firmware version 1.07, allows unauthenticated access to port 5454. This could allow an unauthenticated, remote attacker to connect to this port via Telnet and execute 86 Attention (AT) commands, including some that provide unauthenticated, shell-like access to the device.
This vulnerability allows remote attackers to bypass authentication on affected installations of PaperCut NG 22.0.5 (Build 63914). Authentication is not required to exploit this vulnerability. The specific flaw exists within the SetupCompleted class. The issue results from improper access control. An attacker can leverage this vulnerability to bypass authentication and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-18987.
Apache Struts 2.0.0 through 2.3.15.1 enables Dynamic Method Invocation by default, which has unknown impact and attack vectors.
The invite-anyone plugin before 1.3.16 for WordPress has incorrect access control for email-based invitations.
Vulnerability in the Oracle WebLogic Server component of Oracle Fusion Middleware (subcomponent: Web Services). Supported versions that are affected are 10.3.6.0.0, 12.1.3.0.0 and 12.2.1.3.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.0 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
The Runtime Toolkit in CODESYS Runtime System 2.3.x and 2.4.x does not require authentication, which allows remote attackers to execute commands via the command-line interface in the TCP listener service or transfer files via requests to the TCP listener service.
Unspecified vulnerability in the Java Runtime Environment (JRE) component in Oracle Java SE 7 Update 7 and earlier allows remote attackers to affect confidentiality, integrity, and availability, related to JAX-WS.
Multiple vulnerabilities in the Java Runtime Environment (JRE) component in Oracle Java SE 7 Update 6 and earlier allow remote attackers to execute arbitrary code via a crafted applet that bypasses SecurityManager restrictions by (1) using com.sun.beans.finder.ClassFinder.findClass and leveraging an exception with the forName method to access restricted classes from arbitrary packages such as sun.awt.SunToolkit, then (2) using "reflection with a trusted immediate caller" to leverage the getField method to access and modify private fields, as exploited in the wild in August 2012 using Gondzz.class and Gondvv.class.
Unspecified vulnerability in the Java Runtime Environment (JRE) component in Oracle Java SE 7 update 4 and earlier, 6 update 32 and earlier, 5 update 35 and earlier, and 1.4.2_37 and earlier allows remote attackers to affect confidentiality, integrity, and availability via unknown vectors related to Hotspot.
Certain Symfony products are affected by: Incorrect Access Control. This affects Symfony 2.7.30 and Symfony 2.8.23 and Symfony 3.2.10 and Symfony 3.3.3. The type of exploitation is: remote. The component is: Password validator.
Directory traversal vulnerability in file "jcss.php" in Zikula 1.3.x before 1.3.11 and 1.4.x before 1.4.4 on Windows allows a remote attacker to launch a PHP object injection by uploading a serialized file.
The file scanning mechanism of JFilterInput::isFileSafe() in Joomla! CMS before 3.6.5 does not consider alternative PHP file extensions when checking uploaded files for PHP content, which enables a user to upload and execute files with the `.php6`, `.php7`, `.phtml`, and `.phpt` extensions. Additionally, JHelperMedia::canUpload() did not blacklist these file extensions as uploadable file types.
An issue was discovered in Pivotal RabbitMQ 3.x before 3.5.8 and 3.6.x before 3.6.6 and RabbitMQ for PCF 1.5.x before 1.5.20, 1.6.x before 1.6.12, and 1.7.x before 1.7.7. MQTT (MQ Telemetry Transport) connection authentication with a username/password pair succeeds if an existing username is provided but the password is omitted from the connection request. Connections that use TLS with a client-provided certificate are not affected.
The REPL server (--listen) in GNU Guile 2.0.12 allows an attacker to execute arbitrary code via an HTTP inter-protocol attack.
PHP object injection vulnerabilities exist in multiple widget files in AlienVault OSSIM and USM before 5.3.2. These vulnerabilities allow arbitrary PHP code execution via magic methods in included classes.
MagpieRSS, as used in the front-end component in Nagios Core before 4.2.2 might allow remote attackers to read or write to arbitrary files by spoofing a crafted response from the Nagios RSS feed server. NOTE: this vulnerability exists because of an incomplete fix for CVE-2008-4796.
The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances.
IBM System Storage TS3100-TS3200 Tape Library could allow an unauthenticated user with access to the company network, to change a user's password and gain remote access to the system.
MyBB (aka MyBulletinBoard) before 1.8.7 and MyBB Merge System before 1.8.7 allow attackers to have unspecified impact via vectors related to low adminsid and sid entropy.
Trend Micro Threat Discovery Appliance 2.6.1062r1 and earlier uses predictable session values, which allows remote attackers to bypass authentication by guessing the value.
A remote code execution vulnerability in the Qualcomm crypto driver could enable a remote attacker to execute arbitrary code within the context of the kernel. This issue is rated as Critical due to the possibility of remote code execution in the context of the kernel. Product: Android. Versions: N/A. Android ID: A-32652894. References: QC-CR#1077457.
IBM UrbanCode Deploy could allow a user to execute code using a specially crafted file upload that would replace code on the server. This code could be executed on the UCD agent machines that host customer's production applications.
install/index.php in Exponent CMS 2.3.9 allows remote attackers to execute arbitrary commands via shell metacharacters in the sc array parameter.
sociomantic-tsunami git-hub before 0.10.3 allows remote attackers to execute arbitrary code via a crafted repository name.
The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services.
Improper Access Control in GitHub repository answerdev/answer prior to 1.0.4.
Adobe Reader and Acrobat before 11.0.18, Acrobat and Acrobat Reader DC Classic before 15.006.30243, and Acrobat and Acrobat Reader DC Continuous before 15.020.20039 on Windows and OS X allow attackers to bypass intended access restrictions via unspecified vectors.
libvirt before 2.0.0 improperly disables password checking when the password on a VNC server is set to an empty string, which allows remote attackers to bypass authentication and establish a VNC session by connecting to the server.
Multiple vulnerabilities in Oracle Java 7 before Update 11 allow remote attackers to execute arbitrary code by (1) using the public getMBeanInstantiator method in the JmxMBeanServer class to obtain a reference to a private MBeanInstantiator object, then retrieving arbitrary Class references using the findClass method, and (2) using the Reflection API with recursion in a way that bypasses a security check by the java.lang.invoke.MethodHandles.Lookup.checkSecurityManager method due to the inability of the sun.reflect.Reflection.getCallerClass method to skip frames related to the new reflection API, as exploited in the wild in January 2013, as demonstrated by Blackhole and Nuclear Pack, and a different vulnerability than CVE-2012-4681 and CVE-2012-3174. NOTE: some parties have mapped the recursive Reflection API issue to CVE-2012-3174, but CVE-2012-3174 is for a different vulnerability whose details are not public as of 20130114. CVE-2013-0422 covers both the JMX/MBean and Reflection API issues. NOTE: it was originally reported that Java 6 was also vulnerable, but the reporter has retracted this claim, stating that Java 6 is not exploitable because the relevant code is called in a way that does not bypass security checks. NOTE: as of 20130114, a reliable third party has claimed that the findClass/MBeanInstantiator vector was not fixed in Oracle Java 7 Update 11. If there is still a vulnerable condition, then a separate CVE identifier might be created for the unfixed issue.
The (1) git-remote-ext and (2) unspecified other remote helper programs in Git before 2.3.10, 2.4.x before 2.4.10, 2.5.x before 2.5.4, and 2.6.x before 2.6.1 do not properly restrict the allowed protocols, which might allow remote attackers to execute arbitrary code via a URL in a (a) .gitmodules file or (b) unknown other sources in a submodule.
In Android before 2018-04-05 or earlier security patch level on Qualcomm Snapdragon Mobile SD 425, SD 430, SD 450, SD 625, and SD 650/52, there is improper access control to a bus.
In Android before 2018-04-05 or earlier security patch level on Qualcomm Snapdragon Automobile, Snapdragon Mobile, and Snapdragon Wear MDM9206, SD 210/SD 212/SD 205, SD 425, SD 430, SD 450, SD 625, SD 820, SD 820A, and SD 835, SMMU Access Control Policy was updated to block HLOS from accessing BLSP and BAM resources.
In Android before 2018-04-05 or earlier security patch level on Qualcomm Small Cell SoC, Snapdragon Automobile, Snapdragon Mobile, and Snapdragon Wear FSM9055, IPQ4019, MDM9206, MDM9635M, MDM9640, MDM9645, MDM9650, MDM9655, SD 210/SD 212/SD 205, SD 400, SD 410/12, SD 425, SD 430, SD 450, SD 617, SD 625, SD 650/52, SD 800, SD 808, SD 810, SD 820, SD 820A, SD 835, SD 845, SD 850, and SDX20, improper access control in system call leads to unauthorized access.
In all Qualcomm products with Android releases from CAF using the Linux kernel, a vulnerability exists in a GERAN API.
In all Qualcomm products with Android releases from CAF using the Linux kernel, a vulnerability exists in GNSS when performing a scan after bootup.
The multi-tenant database container feature in SAP HANA does not properly encrypt communications, which allows remote attackers to bypass intended access restrictions and possibly have unspecified other impact via unknown vectors, aka SAP Security Note 2233550.
F5 BIG-IP LTM systems 11.x before 11.2.1 HF16, 11.3.x, 11.4.x before 11.4.1 HF11, 11.5.0, 11.5.1 before HF11, 11.5.2, 11.5.3, 11.5.4 before HF2, 11.6.0 before HF8, 11.6.1 before HF1, 12.0.0 before HF4, and 12.1.0 before HF2 allow remote attackers to modify or extract system configuration files via vectors involving NAT64.
IBM Security Privileged Identity Manager Virtual Appliance version 2.0.2 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials.
Virtual servers in F5 BIG-IP systems 11.5.0, 11.5.1 before HF11, 11.5.2, 11.5.3, 11.5.4 before HF2, 11.6.0 before HF8, 11.6.1 before HF1, 12.0.0 before HF4, and 12.1.0 before HF2, when configured with the HTTP Explicit Proxy functionality or SOCKS profile, allow remote attackers to modify the system configuration, read system files, and possibly execute arbitrary code via unspecified vectors.
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.