The weak password on the web user interface can be exploited via HTTP or HTTPS. Once such access has been obtained, the other passwords can be changed. The weak password on Linux accounts can be accessed via SSH or Telnet, the former of which is by default enabled on trusted interfaces. While the SSH service does not support root login, a user logging in using either of the other Linux accounts may elevate to root access using the su command if they have access to the associated password.
The affected product is vulnerable due to an undocumented interface found on the device, which may allow an attacker to execute commands as root on the device on the N-Tron 702-W / 702M12-W (all versions).
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, uses a hard-coded password to encrypt protected files in transit and at rest, which may allow an attacker to access configuration files.
ZModo ZP-NE14-S and ZP-IBH-13W devices have a hardcoded root password, which makes it easier for remote attackers to obtain access via a TELNET session.
Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Use of Hard-coded Credentials in GitHub repository nuxtlabs/github-module prior to 1.6.2.
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. There is a default password of meinsm for the admin account.
ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices have a hardcoded password of admin for the admin account, a hardcoded password of support for the support account, and a hardcoded password of user for the user account.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
backupmgt/pre_connect_check.php in Seagate BlackArmor NAS contains a hard-coded password of '!~@##$$%FREDESWWSED' for a backdoor user.
Versions of DocuTrac QuicDoc and Office Therapy that ship with DTISQLInstaller.exe version 1.6.4.0 and prior contain three credentials with known passwords: QDMaster, OTMaster, and sa.
D-Link DIR-620 devices, with a certain Rostelekom variant of firmware 1.0.37, have a hardcoded rostel account, which makes it easier for remote attackers to obtain access via a TELNET session.
MASTER IPCAMERA01 3.3.4.2103 devices have a hardcoded password of cat1029 for the root account.
Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration.
Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
In the web server on D-Link DIR-620 devices with a certain customized (by ISP) variant of firmware 1.0.3, 1.0.37, 1.3.1, 1.3.3, 1.3.7, 1.4.0, and 2.0.22, there is a hardcoded password of anonymous for the admin account.
TX9 Automatic Food Dispenser v3.2.57 devices allow access to a shell as root/superuser, a related issue to CVE-2019-16734. To connect, the telnet service is used on port 23 with the default password of 059AnkJ for the root account. The user can then download the filesystem through preinstalled BusyBox utilities (e.g., tar and nc).
Dr. ID Door Access Control and Personnel Attendance Management system uses the hard-code admin default credentials that allows remote attackers to access the system through the default password and obtain the highest permission.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
A vulnerability in the Telnet service of Cisco Small Business RV110W Wireless-N VPN Firewall Routers could allow an unauthenticated, remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. An attacker could exploit this vulnerability by using this default account to connect to the affected system. A successful exploit could allow the attacker to gain full control of an affected device.
A hidden backdoor on PATLITE NH-FB Series devices with firmware version 1.45 or earlier, NH-FV Series devices with firmware version 1.10 or earlier, and NBM Series devices with firmware version 1.09 or earlier allow attackers to enable an SSH daemon via the "kankichi" or "kamiyo4" password to the _secret1.htm URI. Subsequently, the default password of root for the root account allows an attacker to conduct remote code execution and as a result take over the system.
Lens Peek-a-View has a password of 2601hx for the backdoor admin account, a password of user for the backdoor user account, and a password of guest for the backdoor guest account.
D-Link COVR-2600R and COVR-3902 Kit before 1.01b05Beta01 use hardcoded credentials for telnet connection, which allows unauthenticated attackers to gain privileged access to the router, and to extract sensitive data or modify the configuration.
Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.
Swann SWWHD-INTCAM-HD devices have the twipc root password, leading to FTP access as root. NOTE: all affected customers were migrated by 2020-08-31.
Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account.
iBaby M3S has a password of admin for the backdoor admin account.
POSIM EVO 15.13 for Windows includes hardcoded database credentials for the "root" database user. "root" access to POSIM EVO's database may result in a breach of confidentiality, integrity, or availability or allow for attackers to remotely execute code on associated POSIM EVO clients.
Harmonic NSG 9000 devices have a default password of nsgadmin for the admin account, a default password of nsgguest for the guest account, and a default password of nsgconfig for the config account.
The demo feature in Oracle GlassFish Open Source Edition 5.0 has TCP port 7676 open by default with a password of admin for the admin account. This allows remote attackers to obtain potentially sensitive information, perform database operations, or manipulate the demo via a JMX RMI session, aka a "jmx_rmi remote monitoring and control problem." NOTE: this is not an Oracle supported product.
SV3C L-SERIES HD CAMERA V2.3.4.2103-S50-NTD-B20170508B and V2.3.4.2103-S50-NTD-B20170823B devices have a Hard-coded Password.
Emerson DeltaV Smart Switch Command Center application, available in versions 11.3.x and 12.3.1, was unable to change the DeltaV Smart Switches’ management password upon commissioning. Emerson released patches for DeltaV workstations to address this issue, and the patches can be downloaded from Emerson’s Guardian Support Portal. Please refer to the DeltaV Security Notification DSN19003 (KBA NK-1900-0808) for more information about this issue. DeltaV versions 13.3 and higher use the Network Device Command Center application to manage DeltaV Smart Switches, and this newer application is not impacted by this issue. After patching the Smart Switch Command Center, users are required to either commission the DeltaV Smart Switches or change password using the tool.
Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
GateManager versions prior to 9.2c, The affected product contains a hard-coded credential for telnet, allowing an unprivileged attacker to execute commands as root.
A hard-coded password vulnerability was discovered in vApp Manager which is embedded in Dell EMC Unisphere for VMAX, Dell EMC Solutions Enabler, Dell EMC VASA Virtual Appliances, and Dell EMC VMAX Embedded Management (eManagement): Dell EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.18, Dell EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.21, Dell EMC VASA Virtual Appliance versions prior to 8.4.0.514, and Dell EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier). They contain an undocumented default account (smc) with a hard-coded password that may be used with certain web servlets. A remote attacker with the knowledge of the hard-coded password and the message format may use vulnerable servlets to gain unauthorized access to the system. Note: This account cannot be used to log in via the web user interface.
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine