A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web sessions.
A vulnerability has been identified in Polarion Subversion Webclient (All versions). The Polarion subversion web application does not filter user input in a way that prevents Cross-Site Scripting. If a user is enticed into passing specially crafted, malicious input to the web client (e.g. by clicking on a malicious URL with embedded JavaScript), then JavaScript code can be returned and may then be executed by the user’s client. Various actions could be triggered by running malicious JavaScript code.
In J2 Innovations FIN Stack 4.0, the authentication webform is vulnerable to reflected XSS via the query string to /login.
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Cross-site scripting (XSS) vulnerability in the integrated web server in Siemens SINEMA Remote Connect Server before 1.2 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The Group Management page of affected devices is vulnerable to cross-site scripting (XSS). The vulnerability allows an attacker to send malicious JavaScript code which could result in hijacking of the user's cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser action.
Cross-site scripting (XSS) vulnerability in the login form in the integrated web server on Siemens OZW OZW672 devices before 6.00 and OZW772 devices before 6.00 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected components do not properly authenticate heartbeat messages. This could allow an unauthenticated remote attacker to affected the availability of secondary RTLS systems configured using a TeeRevProxy service and potentially cause loss of data generated during the time the attack is ongoing.
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Affected devices load firmware updates without checking the authenticity. Furthermore the integrity of the unencrypted firmware is only verified by a non-cryptographic method. This could allow an attacker to manipulate a firmware update and flash it to the device.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The application does not perform the integrity check of the update packages. Without validation, an admin user might be tricked to install a malicious package, granting root privileges to an attacker.
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Clients do not properly check the integrity of update files. This could allow an unauthenticated remote attacker to alter update files in transit and trick an authorized user into installing malicious code. A successful exploit requires the attacker to be able to modify the communication between server and client on the network.
IP address spoofing when proxying using mod_remoteip and mod_rewrite For configurations using proxying with mod_remoteip and certain mod_rewrite rules, an attacker could spoof their IP address for logging and PHP scripts. Note this issue was fixed in Apache HTTP Server 2.4.24 but was retrospectively allocated a low severity CVE in 2020.
main/java/com/ning/http/client/AsyncHttpClientConfig.java in Async Http Client (aka AHC or async-http-client) before 1.9.0 does not require a hostname match during verification of X.509 certificates, which allows man-in-the-middle attackers to spoof HTTPS servers via an arbitrary valid certificate.
com.proxyman.NSProxy.HelperTool in Privileged Helper Tool in Proxyman for macOS 1.11.0 and earlier allows an attacker to change the System Proxy and redirect all traffic to an attacker-controlled computer, enabling MITM attacks.
Cisco Webex Business Suite before 39.1.0 contains a vulnerability that could allow an unauthenticated, remote attacker to affect the integrity of the application. The vulnerability is due to improper validation of host header values. An attacker with a privileged network position, either a man-in-the-middle or by intercepting wireless network traffic, could exploit this vulnerability to manipulate header values sent by a client to the affected application. The attacker could cause the application to use input from the header to redirect a user from the Cisco Webex Meetings Online site to an arbitrary site of the attacker's choosing.
A vulnerability in the MP3 detection engine of Cisco AsyncOS Software for Cisco Email Security Appliance (ESA) could allow an unauthenticated, remote attacker to bypass configured content filters on the device. The vulnerability is due to improper validation of certain MP3 file types. An attacker could exploit this vulnerability by sending a crafted MP3 file through the targeted device. A successful exploit could allow the attacker to bypass configured content filters that would normally drop the email.
In Hunesion i-oneNet version 3.0.7 ~ 3.0.53 and 4.0.4 ~ 4.0.16, due to the lack of update file integrity checking in the upgrade process, an attacker can craft malicious file and use it as an update.
A logic issue was addressed with improved state management. This issue is fixed in macOS Big Sur 11.4, Security Update 2021-003 Catalina, Security Update 2021-004 Mojave. A malicious application may bypass Gatekeeper checks.
A Insufficient Verification of Data Authenticity vulnerability in autoyast2 of SUSE Linux Enterprise Server 12, SUSE Linux Enterprise Server 15 allows remote attackers to MITM connections when deprecated and unused functionality of autoyast is used to create images. This issue affects: SUSE Linux Enterprise Server 12 autoyast2 version 4.1.9-3.9.1 and prior versions. SUSE Linux Enterprise Server 15 autoyast2 version 4.0.70-3.20.1 and prior versions.
Through complicated navigations with new windows, an HTTP page could have inherited a secure lock icon from an HTTPS page. This vulnerability affects Firefox ESR < 78.10, Thunderbird < 78.10, and Firefox < 88.
A content spoofing vulnerability in the following components allows to render html pages containing arbitrary plain text content, which might fool an end user: UI add-on for SAP NetWeaver (UI_Infra, 1.0), SAP UI Implementation for Decoupled Innovations (UI_700, 2.0): SAP NetWeaver 7.00 Implementation, SAP User Interface Technology (SAP_UI 7.4, 7.5, 7.51, 7.52). There is little impact as it is not possible to embed active contents such as JavaScript or hyperlinks.
Async Http Client (aka AHC or async-http-client) before 1.9.0 skips X.509 certificate verification unless both a keyStore location and a trustStore location are explicitly set, which allows man-in-the-middle attackers to spoof HTTPS servers by presenting an arbitrary certificate during use of a typical AHC configuration, as demonstrated by a configuration that does not send client certificates.
Nextcloud Server is the file server software for Nextcloud, a self-hosted productivity platform. Prior to versions 21.0.8, 22.2.4, and 23.0.1, it is possible to trick administrators into enabling "recommended" apps for the Nextcloud server that they do not need, thus expanding their attack surface unnecessarily. This issue is fixed in versions 21.0.8 , 22.2.4, and 23.0.1.
The CORS Filter in Apache Tomcat 9.0.0.M1 to 9.0.0.M21, 8.5.0 to 8.5.15, 8.0.0.RC1 to 8.0.44 and 7.0.41 to 7.0.78 did not add an HTTP Vary header indicating that the response varies depending on Origin. This permitted client and server side cache poisoning in some circumstances.
IBM DataPower Gateways 7.1, 7,2, 7.5, and 7.6 could allow an attacker using man-in-the-middle techniques to spoof DNS responses to perform DNS cache poisoning and redirect Internet traffic. IBM X-Force ID: 136817.
The Frontel protocol before 3 on RSI Video Technologies Videofied devices does not use integrity protection, which makes it easier for man-in-the-middle attackers to (1) initiate a false alarm or (2) deactivate an alarm by modifying the client-server data stream.
This vulnerability arises because the application allows the user to perform some sensitive action without verifying that the request was sent intentionally. An attacker can cause a victim's browser to emit an HTTP request to an arbitrary URL in the application.
Address bar search suggestions in private browsing mode were re-using session data from normal mode. *This bug only affects Firefox for Android. Other operating systems are unaffected.*. This vulnerability affects Firefox < 89.
This issue was addressed with improved handling of file metadata. This issue is fixed in macOS Big Sur 11.3. A malicious application may bypass Gatekeeper checks.
Dell EMC PowerFlex, v3.5.x contain a Cross-Site WebSocket Hijacking Vulnerability in the Presentation Server/WebUI. An unauthenticated attacker could potentially exploit this vulnerability by tricking the user into performing unwanted actions on the Presentation Server and perform which may lead to configuration changes.
matrix-react-sdk is an npm package which is a Matrix SDK for React Javascript. In matrix-react-sdk before version 3.15.0, the user content sandbox can be abused to trick users into opening unexpected documents. The content is opened with a `blob` origin that cannot access Matrix user data, so messages and secrets are not at risk. This has been fixed in version 3.15.0.
An issue existed in the handling of iMessage tapbacks. The issue was resolved with additional verification. This issue is fixed in iOS 13.6 and iPadOS 13.6, macOS Catalina 10.15.6, tvOS 13.4.8, watchOS 6.2.8. A user that is removed from an iMessage group could rejoin the group.
AppImage appimaged before 1.0.3 does not properly check whether a downloaded file is a valid appimage. For example, it will accept a crafted mp3 file that contains an appimage, and install it.
resolv.c in the DNS resolver in uIP, and dns.c in the DNS resolver in lwIP 1.4.1 and earlier, does not use random values for ID fields and source ports of DNS query packets, which makes it easier for man-in-the-middle attackers to conduct cache-poisoning attacks via spoofed reply packets.
When SAML authentication is enabled, Juniper Networks Mist Cloud UI might incorrectly handle child elements in SAML responses, allowing a remote attacker to modify a valid SAML response without invalidating its cryptographic signature to bypass SAML authentication security controls. This issue affects all Juniper Networks Mist Cloud UI versions prior to September 2 2020.
jitsi-meet-electron (aka Jitsi Meet Electron) before 2.3.0 calls the Electron shell.openExternal function without verifying that the URL is for an http or https resource, in some circumstances.
Apple Software Update before 2.2 on Windows does not use HTTPS, which makes it easier for man-in-the-middle attackers to spoof updates by modifying the client-server data stream.
The caching functionality in the TrustManagerImpl class in TrustManagerImpl.java in Conscrypt in Android 4.x before 4.4.4, 5.x before 5.1.1 LMY49H, and 6.x before 2016-03-01 mishandles the distinction between an intermediate CA and a trusted root CA, which allows man-in-the-middle attackers to spoof servers by leveraging access to an intermediate CA to issue a certificate, aka internal bug 26232830.
Ansible before 1.9.2 does not verify that the server hostname matches a domain name in the subject's Common Name (CN) or subjectAltName field of the X.509 certificate, which allows man-in-the-middle attackers to spoof SSL servers via an arbitrary valid certificate.