Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2017-12756

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-09 Aug, 2017 | 21:00
Updated At-05 Aug, 2024 | 18:51
Rejected At-
Credits

Command inject in transfer from another server in extplorer 2.1.9 and prior allows attacker to inject command via the userfile[0] parameter.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:09 Aug, 2017 | 21:00
Updated At:05 Aug, 2024 | 18:51
Rejected At:
▼CVE Numbering Authority (CNA)

Command inject in transfer from another server in extplorer 2.1.9 and prior allows attacker to inject command via the userfile[0] parameter.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://extplorer.net/news/21
x_refsource_CONFIRM
Hyperlink: http://extplorer.net/news/21
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://extplorer.net/news/21
x_refsource_CONFIRM
x_transferred
Hyperlink: http://extplorer.net/news/21
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:09 Aug, 2017 | 21:29
Updated At:20 Apr, 2025 | 01:37

Command inject in transfer from another server in extplorer 2.1.9 and prior allows attacker to inject command via the userfile[0] parameter.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.07.2HIGH
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.0
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

extplorer
extplorer
>>extplorer>>Versions up to 2.1.9(inclusive)
cpe:2.3:a:extplorer:extplorer:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://extplorer.net/news/21cve@mitre.org
Release Notes
Vendor Advisory
http://extplorer.net/news/21af854a3a-2127-422b-91ae-364da2661108
Release Notes
Vendor Advisory
Hyperlink: http://extplorer.net/news/21
Source: cve@mitre.org
Resource:
Release Notes
Vendor Advisory
Hyperlink: http://extplorer.net/news/21
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Release Notes
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

455Records found

CVE-2025-4340
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.53% / 66.87%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 08:00
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-890L/DIR-806A1 soap.cgi sub_175C8 command injection

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-806_firmwaredir-890ldir-806dir-890l_firmwareDIR-806A1DIR-890L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4341
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.37% / 58.40%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 08:31
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-880L Request Header ssdpcgi sub_16570 command injection

A vulnerability classified as critical was found in D-Link DIR-880L up to 104WWb01. Affected by this vulnerability is the function sub_16570 of the file /htdocs/ssdpcgi of the component Request Header Handler. The manipulation of the argument HTTP_ST/REMOTE_ADDR/REMOTE_PORT/SERVER_ID leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-880l_firmwaredir-880lDIR-880L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-9116
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-7.2||HIGH
EPSS-1.47% / 80.64%
||
7 Day CHG~0.00%
Published-30 Nov, 2020 | 23:53
Updated-04 Aug, 2024 | 10:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Huawei FusionCompute versions 6.5.1 and 8.0.0 have a command injection vulnerability. An authenticated, remote attacker can craft specific request to exploit this vulnerability. Due to insufficient verification, this could be exploited to cause the attackers to obtain higher privilege.

Action-Not Available
Vendor-n/aHuawei Technologies Co., Ltd.
Product-fusioncomputeFusionCompute
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4135
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.17% / 78.35%
||
7 Day CHG+0.79%
Published-30 Apr, 2025 | 17:31
Updated-23 Jun, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear WG302v2 ui_get_input_value command injection

A vulnerability was found in Netgear WG302v2 up to 5.2.9 and classified as critical. Affected by this issue is the function ui_get_input_value. The manipulation of the argument host leads to command injection. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-wg302v2wg302v2_firmwareWG302v2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4121
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.81% / 82.55%
||
7 Day CHG+1.31%
Published-30 Apr, 2025 | 14:00
Updated-13 May, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear JWNR2000v2 cmd_wireless command injection

A vulnerability was found in Netgear JWNR2000v2 1.0.0.11. It has been declared as critical. Affected by this vulnerability is the function cmd_wireless. The manipulation of the argument host leads to command injection. The attack can be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-jwnr2000v2_firmwarejwnr2000v2JWNR2000v2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4122
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.75% / 82.29%
||
7 Day CHG+1.27%
Published-30 Apr, 2025 | 14:31
Updated-12 May, 2025 | 19:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear JWNR2000v2 sub_435E04 command injection

A vulnerability was found in Netgear JWNR2000v2 1.0.0.11. It has been rated as critical. Affected by this issue is the function sub_435E04. The manipulation of the argument host leads to command injection. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-jwnr2000v2_firmwarejwnr2000v2JWNR2000v2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-8188
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-0.94% / 75.99%
||
7 Day CHG~0.00%
Published-02 Jul, 2020 | 18:35
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

We have recently released new version of UniFi Protect firmware v1.13.3 and v1.14.10 for Unifi Cloud Key Gen2 Plus and UniFi Dream Machine Pro/UNVR respectively that fixes vulnerabilities found on Protect firmware v1.13.2, v1.14.9 and prior according to the description below:View only users can run certain custom commands which allows them to assign themselves unauthorized roles and escalate their privileges.

Action-Not Available
Vendor-n/aUbiquiti Inc.
Product-unifi_protect_firmwareunifi_protectunifi_dream_machine_prounifi_cloud_key_plusProtect for UniFi Cloud Key Gen2 Plus, UniFi Dream Machine Pro, UNVR
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-4076
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.15% / 78.22%
||
7 Day CHG+0.78%
Published-29 Apr, 2025 | 18:00
Updated-02 May, 2025 | 13:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK BL-AC3600 Password lighttpd.cgi easy_uci_set_option_string_0 command injection

A vulnerability classified as critical has been found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function easy_uci_set_option_string_0 of the file /cgi-bin/lighttpd.cgi of the component Password Handler. The manipulation of the argument routepwd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-LB-LINK
Product-BL-AC3600
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-3987
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-8.89% / 92.39%
||
7 Day CHG~0.00%
Published-27 Apr, 2025 | 21:31
Updated-07 May, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N150RT formWsc command injection

A vulnerability was found in TOTOLINK N150RT 3.4.0-B20190525. It has been rated as critical. This issue affects some unknown processing of the file /boafrm/formWsc. The manipulation of the argument localPin leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n150rt_firmwaren150rtN150RT
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-3249
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-6.40% / 90.83%
||
7 Day CHG~0.00%
Published-04 Apr, 2025 | 14:00
Updated-28 May, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK A6000R mtkwifi.lua apcli_cancel_wps command injection

A vulnerability classified as critical was found in TOTOLINK A6000R 1.0.1-B20201211.2000. Affected by this vulnerability is the function apcli_cancel_wps of the file /usr/lib/lua/luci/controller/mtkwifi.lua. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-a6000r_firmwarea6000rA6000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-22938
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-7.2||HIGH
EPSS-4.29% / 88.64%
||
7 Day CHG~0.00%
Published-16 Aug, 2021 | 18:38
Updated-03 Aug, 2024 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in Pulse Connect Secure before 9.1R12 could allow an authenticated administrator to perform command injection via an unsanitized web parameter in the administrator web console.

Action-Not Available
Vendor-n/aIvanti SoftwarePulse Secure
Product-pulse_connect_secureconnect_securePulse Connect Secure
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-7825
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.36% / 79.89%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:32
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen PelcoSarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2015-4336
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-1.46% / 80.56%
||
7 Day CHG~0.00%
Published-17 Jun, 2015 | 18:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

cloner.functions.php in the XCloner plugin 3.1.2 for WordPress allows remote authenticated users to execute arbitrary commands via a file containing filenames with shell metacharacters, as demonstrated by using the backup comments feature to create the file.

Action-Not Available
Vendor-xclonern/a
Product-xclonern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-15356
Matching Score-4
Assigner-Kaspersky
ShareView Details
Matching Score-4
Assigner-Kaspersky
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.57%
||
7 Day CHG~0.00%
Published-17 Aug, 2018 | 15:00
Updated-05 Aug, 2024 | 09:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authenticated attacker can execute arbitrary code using command ejection in Eltex ESP-200 firmware version 1.2.0.

Action-Not Available
Vendor-eltexKaspersky Lab
Product-esp-200esp-200_firmwareEltex ESP-200
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2015-2746
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-43.91% / 97.45%
||
7 Day CHG~0.00%
Published-26 Mar, 2015 | 14:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.

Action-Not Available
Vendor-websensen/a
Product-tritonv-series_appliancesn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2015-1561
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-5.24% / 89.77%
||
7 Day CHG~0.00%
Published-14 Jul, 2015 | 16:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The escape_command function in include/Administration/corePerformance/getStats.php in Centreon (formerly Merethis Centreon) 2.5.4 and earlier (fixed in Centreon 19.10.0) uses an incorrect regular expression, which allows remote authenticated users to execute arbitrary commands via shell metacharacters in the ns_id parameter.

Action-Not Available
Vendor-n/aCENTREON
Product-centreonn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2015-0934
Matching Score-4
Assigner-CERT/CC
ShareView Details
Matching Score-4
Assigner-CERT/CC
CVSS Score-6.5||MEDIUM
EPSS-1.55% / 81.16%
||
7 Day CHG~0.00%
Published-04 Mar, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Common LaTeX Service Interface (CLSI) before 0.1.3, as used in ShareLaTeX before 0.1.3, allows remote authenticated users to execute arbitrary code via ` (backtick) characters in a filename.

Action-Not Available
Vendor-sharelatexn/a
Product-sharelatexn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-7181
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.31% / 87.02%
||
7 Day CHG~0.00%
Published-29 Jul, 2024 | 03:31
Updated-23 Aug, 2024 | 14:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK A3600R cstecgi.cgi setTelnetCfg command injection

A vulnerability classified as critical was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. This vulnerability affects the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument telnet_enabled leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272602 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-a3600r_firmwarea3600rA3600Ra3600r_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-12465
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
ShareView Details
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
CVSS Score-9.1||CRITICAL
EPSS-82.23% / 99.19%
||
7 Day CHG~0.00%
Published-29 Jun, 2018 | 16:00
Updated-16 Sep, 2024 | 20:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Remote Code Execution in Micro Focus Secure Messaging Gateway

An OS command injection vulnerability in the web administration component of Micro Focus Secure Messaging Gateway (SMG) allows a remote attacker authenticated as a privileged user to execute arbitrary OS commands on the SMG server. This can be exploited in conjunction with CVE-2018-12464 to achieve unauthenticated remote code execution. Affects Micro Focus Secure Messaging Gateway versions prior to 471. It does not affect previous versions of the product that used GWAVA product name (i.e. GWAVA 6.5).

Action-Not Available
Vendor-Micro Focus International Limited
Product-secure_messaging_gatewaySecure Messaging Gateway
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-2916
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.05% / 77.24%
||
7 Day CHG~0.00%
Published-28 Mar, 2025 | 17:00
Updated-28 Mar, 2025 | 18:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Aishida Call Center System amr2mp3 command injection

A vulnerability, which was classified as critical, has been found in Aishida Call Center System up to 20250314. This issue affects some unknown processing of the file /doscall/weixin/open/amr2mp3. The manipulation of the argument File leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Aishida
Product-Call Center System
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-1244
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-8.8||HIGH
EPSS-1.34% / 79.72%
||
7 Day CHG~0.00%
Published-02 Jul, 2018 | 17:00
Updated-16 Sep, 2024 | 16:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
iDRAC7/iDRAC8/iDrac9 contains a command injection vulnerability in the SNMP agent.

Dell EMC iDRAC7/iDRAC8, versions prior to 2.60.60.60, and iDRAC9 versions prior to 3.21.21.21 contain a command injection vulnerability in the SNMP agent. A remote authenticated malicious iDRAC user with configuration privileges could potentially exploit this vulnerability to execute arbitrary commands on the iDRAC where SNMP alerting is enabled.

Action-Not Available
Vendor-Dell Inc.
Product-idrac9_firmwareidrac7_firmwareidrac8_firmwareiDRAC8iDRAC9iDRAC7
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-24390
Matching Score-4
Assigner-Fidelis Security, LLC
ShareView Details
Matching Score-4
Assigner-Fidelis Security, LLC
CVSS Score-8.8||HIGH
EPSS-0.82% / 74.14%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:27
Updated-16 Sep, 2024 | 16:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “remote_text_file” enables an attacker with user level access to the CLI to inject user level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2014-8903
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-8.8||HIGH
EPSS-0.85% / 74.58%
||
7 Day CHG~0.00%
Published-02 Aug, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Curam Social Program Management 6.0 SP2 before EP26, 6.0.4 before 6.0.4.5iFix10 and 6.0.5 before 6.0.5.6 allows remote authenticated users to load arbitrary Java classes via unspecified vectors.

Action-Not Available
Vendor-n/aIBM Corporation
Product-curam_social_program_managementn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-2701
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.57% / 85.28%
||
7 Day CHG~0.00%
Published-24 Mar, 2025 | 09:00
Updated-17 Oct, 2025 | 17:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
AMTT Hotel Broadband Operation System port_setup.php popen os command injection

A vulnerability classified as critical was found in AMTT Hotel Broadband Operation System 1.0. This vulnerability affects the function popen of the file /manager/network/port_setup.php. The manipulation of the argument SwitchVersion/SwitchWrite/SwitchIP/SwitchIndex/SwitchState leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-AMTT
Product-hibosHotel Broadband Operation System
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-2733
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.42% / 61.44%
||
7 Day CHG~0.00%
Published-25 Mar, 2025 | 04:31
Updated-27 Mar, 2025 | 16:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
mannaandpoem OpenManus Prompt python_execute.py os command injection

A vulnerability classified as critical has been found in mannaandpoem OpenManus up to 2025.3.13. This affects an unknown part of the file app/tool/python_execute.py of the component Prompt Handler. The manipulation leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-mannaandpoem
Product-OpenManus
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-7826
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.36% / 79.89%
||
7 Day CHG~0.00%
Published-22 May, 2019 | 19:33
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-3278
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-1.34% / 79.77%
||
7 Day CHG~0.00%
Published-18 Jun, 2020 | 02:15
Updated-15 Nov, 2024 | 17:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Small Business RV Series Routers Command Injection Vulnerabilities

Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV320 and RV325 Series Routers and Cisco Small Business RV016, RV042, and RV082 Routers could allow an authenticated, remote attacker with administrative privileges to execute arbitrary commands on an affected device. The vulnerabilities exist because the web-based management interface does not properly validate user-supplied input to scripts. An attacker with administrative privileges that are sufficient to log in to the web-based management interface could exploit each vulnerability by sending malicious requests to an affected device. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the underlying operating system.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv325rv320rv042rv016_firmwarerv042grv082rv320_firmwarerv042_firmwarerv325_firmwarerv082_firmwarerv016rv042g_firmwareCisco Small Business RV Series Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-2367
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.44% / 62.93%
||
7 Day CHG~0.00%
Published-17 Mar, 2025 | 07:31
Updated-17 Mar, 2025 | 14:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Oiwtech OIW-2431APGN-HP Personal Script Submenu formScript os command injection

A vulnerability has been found in Oiwtech OIW-2431APGN-HP 2.5.3-B20131128 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formScript of the component Personal Script Submenu. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Oiwtech
Product-OIW-2431APGN-HP
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-4636
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-8.2||HIGH
EPSS-0.67% / 70.99%
||
7 Day CHG~0.00%
Published-16 Oct, 2020 | 16:40
Updated-16 Sep, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Resilient OnPrem 38.2 could allow a privileged user to inject malicious commands through Python3 scripting. IBM X-Force ID: 185503.

Action-Not Available
Vendor-IBM CorporationLinux Kernel Organization, Inc
Product-resilient_security_orchestration_automation_and_responselinux_kernelResilient OnPrem
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-1946
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-4.84% / 89.33%
||
7 Day CHG~0.00%
Published-04 Mar, 2025 | 18:31
Updated-29 Jan, 2026 | 20:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
hzmanyun Education and Training System exportPDF command injection

A vulnerability was found in hzmanyun Education and Training System 2.1. It has been rated as critical. Affected by this issue is the function exportPDF of the file /user/exportPDF. The manipulation of the argument id leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-hzmanyunhzmanyun
Product-education_and_training_systemEducation and Training System
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-2096
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-4.22% / 88.54%
||
7 Day CHG~0.00%
Published-07 Mar, 2025 | 22:00
Updated-03 Apr, 2025 | 15:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK EX1800T cstecgi.cgi setRebootScheCfg os command injection

A vulnerability classified as critical was found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This vulnerability affects the function setRebootScheCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument mode/week/minute/recHour leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ex1800tex1800t_firmwareEX1800T
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-2094
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-6.92% / 91.23%
||
7 Day CHG~0.00%
Published-07 Mar, 2025 | 21:31
Updated-03 Apr, 2025 | 15:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK EX1800T cstecgi.cgi setWiFiExtenderConfig os command injection

A vulnerability was found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. It has been rated as critical. Affected by this issue is the function setWiFiExtenderConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument apcliKey/key leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ex1800tex1800t_firmwareEX1800T
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-2095
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-4.22% / 88.54%
||
7 Day CHG~0.00%
Published-07 Mar, 2025 | 22:00
Updated-03 Apr, 2025 | 15:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK EX1800T cstecgi.cgi setDmzCfg os command injection

A vulnerability classified as critical has been found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This affects the function setDmzCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ip leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ex1800tex1800t_firmwareEX1800T
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-1947
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.88% / 88.02%
||
7 Day CHG~0.00%
Published-04 Mar, 2025 | 18:31
Updated-29 Jan, 2026 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
hzmanyun Education and Training System UploadImageController.java scorm command injection

A vulnerability classified as critical has been found in hzmanyun Education and Training System 2.1.3. This affects the function scorm of the file UploadImageController.java. The manipulation of the argument param leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-hzmanyunhzmanyun
Product-education_and_training_systemEducation and Training System
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-15081
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.42% / 61.59%
||
7 Day CHG~0.00%
Published-25 Dec, 2025 | 15:02
Updated-29 Dec, 2025 | 15:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
JD Cloud BE6500 jdcapi sub_4780 command injection

A vulnerability has been found in JD Cloud BE6500 4.4.1.r4308. This issue affects the function sub_4780 of the file /jdcapi. Such manipulation of the argument ddns_name leads to command injection. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-JD
Product-Cloud BE6500
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-1829
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.42% / 87.22%
||
7 Day CHG~0.00%
Published-02 Mar, 2025 | 19:00
Updated-03 Apr, 2025 | 15:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X18 cstecgi.cgi setMtknatCfg os command injection

A vulnerability was found in TOTOLINK X18 9.1.0cu.2024_B20220329. It has been declared as critical. This vulnerability affects the function setMtknatCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument mtkhnatEnable leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-x18x18_firmwareX18
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-15191
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.23% / 45.76%
||
7 Day CHG~0.00%
Published-29 Dec, 2025 | 14:02
Updated-30 Dec, 2025 | 20:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M920 formLtefotaUpgradeFibocom sub_4155B4 command injection

A weakness has been identified in D-Link DWR-M920 up to 1.1.50. The affected element is the function sub_4155B4 of the file /boafrm/formLtefotaUpgradeFibocom. This manipulation of the argument fota_url causes command injection. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m920_firmwaredwr-m920DWR-M920
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-1676
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.40% / 80.14%
||
7 Day CHG~0.00%
Published-25 Feb, 2025 | 11:00
Updated-29 Jan, 2026 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
hzmanyun Education and Training System pdf2swf os command injection

A vulnerability classified as critical was found in hzmanyun Education and Training System 3.1.1. Affected by this vulnerability is the function pdf2swf of the file /pdf2swf. The manipulation of the argument file leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-hzmanyunhzmanyun
Product-education_and_training_systemEducation and Training System
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-1845
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.21% / 78.74%
||
7 Day CHG~0.00%
Published-03 Mar, 2025 | 02:00
Updated-28 May, 2025 | 17:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ESAFENET DSM examExportPDF command injection

A vulnerability has been found in ESAFENET DSM 3.1.2 and classified as critical. Affected by this vulnerability is the function examExportPDF of the file /admin/plan/examExportPDF. The manipulation of the argument s leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-esafenetESAFENET
Product-dsmDSM
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-1610
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.76% / 73.11%
||
7 Day CHG~0.00%
Published-24 Feb, 2025 | 01:31
Updated-04 Nov, 2025 | 21:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK AC1900 Router set_blacklist websGetVar os command injection

A vulnerability was found in LB-LINK AC1900 Router 1.0.2 and classified as critical. Affected by this issue is the function websGetVar of the file /goform/set_blacklist. The manipulation of the argument mac/enable leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-lb-linkLB-LINK
Product-ac1900_firmwareac1900AC1900 Router
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-15132
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.51%
||
7 Day CHG~0.00%
Published-28 Dec, 2025 | 10:32
Updated-07 Jan, 2026 | 21:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ZSPACE Z4Pro+ HTTP POST Request open zfilev2_api_open command injection

A vulnerability was determined in ZSPACE Z4Pro+ 1.0.0440024. The affected element is the function zfilev2_api_open of the file /v2/file/safe/open of the component HTTP POST Request Handler. This manipulation causes command injection. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure.

Action-Not Available
Vendor-zspaceZSPACE
Product-z4pro\+z4pro\+_firmwareZ4Pro+
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-1608
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.76% / 73.11%
||
7 Day CHG~0.00%
Published-24 Feb, 2025 | 00:31
Updated-04 Nov, 2025 | 20:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK AC1900 Router set_manpwd websGetVar os command injection

A vulnerability, which was classified as critical, was found in LB-LINK AC1900 Router 1.0.2. Affected is the function websGetVar of the file /goform/set_manpwd. The manipulation of the argument routepwd  leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-lb-linkLB-LINK
Product-ac1900_firmwareac1900AC1900 Router
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-15254
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.04% / 77.12%
||
7 Day CHG~0.00%
Published-30 Dec, 2025 | 15:32
Updated-24 Feb, 2026 | 07:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W6-S ATE Service ate TendaAte os command injection

A vulnerability was found in Tenda W6-S 1.0.0.4(510). This affects the function TendaAte of the file /goform/ate of the component ATE Service. Performing a manipulation results in os command injection. The attack may be initiated remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w6-s_firmwarew6-sW6-S
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-15139
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.60% / 68.99%
||
7 Day CHG~0.00%
Published-28 Dec, 2025 | 14:02
Updated-24 Feb, 2026 | 06:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TRENDnet TEW-822DRE formWsc sub_43ACF4  command injection

A vulnerability has been found in TRENDnet TEW-822DRE 1.00B21/1.01B06. This affects the function sub_43ACF4  of the file /boafrm/formWsc. Such manipulation of the argument peerPin leads to command injection. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TRENDnet, Inc.
Product-tew-822dretew-822dre_firmwareTEW-822DRE
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-14586
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.50% / 80.85%
||
7 Day CHG-0.17%
Published-13 Dec, 2025 | 06:32
Updated-24 Feb, 2026 | 05:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X5000R cstecgi.cgi snprintf os command injection

A vulnerability was determined in TOTOLINK X5000R 9.1.0cu.2089_B20211224. Affected by this issue is the function snprintf of the file /cgi-bin/cstecgi.cgi?action=exportOvpn&type=user. This manipulation of the argument User causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-TOTOLINK
Product-x5000r_firmwarex5000rX5000R
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-14225
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 33.51%
||
7 Day CHG~0.00%
Published-08 Dec, 2025 | 09:02
Updated-11 Dec, 2025 | 00:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-930L alphapd setSystemAdmin command injection

A vulnerability was determined in D-Link DCS-930L 1.15.04. This affects an unknown part of the file /setSystemAdmin of the component alphapd. Executing manipulation of the argument AdminID can lead to command injection. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-930ldcs-930l_firmwareDCS-930L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-14204
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.51% / 80.93%
||
7 Day CHG~0.00%
Published-07 Dec, 2025 | 23:02
Updated-08 Dec, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TykoDev cherry-studio-TykoFork OAuth Server Discovery oauth-authorization-server redirectToAuthorization os command injection

A vulnerability has been found in TykoDev cherry-studio-TykoFork 0.1. This issue affects the function redirectToAuthorization of the file /.well-known/oauth-authorization-server of the component OAuth Server Discovery. Such manipulation of the argument authorizationUrl leads to os command injection. The attack can be executed remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TykoDev
Product-cherry-studio-TykoFork
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-14208
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.77% / 73.20%
||
7 Day CHG~0.00%
Published-08 Dec, 2025 | 01:02
Updated-08 Dec, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_wan_settings sub_415028 command injection

A security flaw has been discovered in D-Link DIR-823X up to 20250416. This affects the function sub_415028 of the file /goform/set_wan_settings. The manipulation of the argument ppp_username results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be exploited.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-13798
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.83%
||
7 Day CHG~0.00%
Published-01 Dec, 2025 | 00:32
Updated-11 Dec, 2025 | 22:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ADSLR NBR1005GPEV2 send_order.cgi ap_macfilter_add command injection

A flaw has been found in ADSLR NBR1005GPEV2 250814-r037c. This affects the function ap_macfilter_add of the file /send_order.cgi. Executing manipulation of the argument mac can lead to command injection. The attack may be performed from remote. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-adslrADSLR
Product-b-qe2w401b-qe2w401_firmwareNBR1005GPEV2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-13800
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 61.01%
||
7 Day CHG~0.00%
Published-01 Dec, 2025 | 01:32
Updated-11 Dec, 2025 | 22:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ADSLR NBR1005GPEV2 send_order.cgi set_mesh_disconnect command injection

A vulnerability was found in ADSLR NBR1005GPEV2 250814-r037c. This issue affects the function set_mesh_disconnect of the file /send_order.cgi. The manipulation of the argument mac results in command injection. It is possible to launch the attack remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-adslrADSLR
Product-b-qe2w401b-qe2w401_firmwareNBR1005GPEV2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • ...
  • 6
  • 7
  • 8
  • 9
  • 10
  • Next
Details not found