GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
The Epson "EasyMP" software is designed to remotely stream a users computer to supporting projectors.These devices are authenticated using a unique 4-digit code, displayed on-screen - ensuring only those who can view it are streaming.In addition to the password, each projector has a hardcoded "backdoor" code (2270), which authenticates to all devices.
A hard-coded password of tecn0visi0n for the dlxuser account in TecnoVISION DLX Spot Player4 (all known versions) allows remote attackers to log in via SSH and escalate privileges to root access with the same credentials.
GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
An issue was discovered on the PLANEX CS-QR20 1.30. A hardcoded account / password ("admin:password") is used in the Android application that allows attackers to use a hidden API URL "/goform/SystemCommand" to execute any command with root permission.
An issue was discovered on PLANEX CS-W50HD devices with firmware before 030720. A hardcoded credential "supervisor:dangerous" was injected into web authentication database "/.htpasswd" during booting process, which allows attackers to gain unauthorized access and control the device completely; the account can't be modified or deleted.
An issue was discovered on Wireless IP Camera 360 devices. Remote attackers can discover a weakly encoded admin password by connecting to TCP port 9527 and reading the password field of the debugging information, e.g., nTBCS19C corresponds to a password of 123456.
MEDHOST Connex contains a hard-coded Mirth Connect admin credential that is used for customer Mirth Connect management access. An attacker with knowledge of the hard-coded credential and the ability to communicate directly with the Mirth Connect management console may be able to intercept sensitive patient information. The admin account password is hard-coded as $K8t1ng throughout the application, and is the same across all installations. Customers do not have the option to change the Mirth Connect admin account password. The Mirth Connect admin account is created during the Connex install. The plaintext account password is hard-coded multiple times in the Connex install and update scripts.
MEDHOST Connex contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. Connex utilizes an IBM i DB2 user account for database access. The account name is HMSCXPDN. Its password is hard-coded in multiple places in the application. Customers do not have the option to change this password. The account has elevated DB2 roles, and can access all objects or database tables on the customer DB2 database. This account can access data through ODBC, FTP, and TELNET. Customers without Connex installed are still vulnerable because the MEDHOST setup program creates this account.
IBM Tealeaf Customer Experience 8.7, 8.8, and 9.0.2 contains hard-coded credentials. A remote attacker could exploit this vulnerability to gain access to the system. IBM X-Force ID: 123740.
An issue was discovered on Wireless IP Camera 360 devices. A root account with a known SHA-512 password hash exists, which makes it easier for remote attackers to obtain administrative access via a TELNET session.
D-Link DIR-615 before v20.12PTb04 has a second admin account with a 0x1 BACKDOOR value, which might allow remote attackers to obtain access via a TELNET connection.
MCMS v5.2.4 was discovered to have a hardcoded shiro-key, allowing attackers to exploit the key and execute arbitrary code.
An issue was discovered in heinekingmedia StashCat through 1.7.5 for Android. The keystore is locked with a hard-coded password. Therefore, everyone with access to the keystore can read the content out, for example the private key of the user.
Backup archives were found to be encrypted with a static password across different installations, which suggest the same password may be used in all virtual appliance instances of Trend Micro Deep Discovery Director 1.1.
IBM dashDB Local uses hard-coded credentials that could allow a remote attacker to gain access to the Docker container or database.
The JWT library in NATS nats-server before 2.1.9 has Incorrect Access Control because of how expired credentials are handled.
Emerson DeltaV Smart Switch Command Center application, available in versions 11.3.x and 12.3.1, was unable to change the DeltaV Smart Switches’ management password upon commissioning. Emerson released patches for DeltaV workstations to address this issue, and the patches can be downloaded from Emerson’s Guardian Support Portal. Please refer to the DeltaV Security Notification DSN19003 (KBA NK-1900-0808) for more information about this issue. DeltaV versions 13.3 and higher use the Network Device Command Center application to manage DeltaV Smart Switches, and this newer application is not impacted by this issue. After patching the Smart Switch Command Center, users are required to either commission the DeltaV Smart Switches or change password using the tool.
Django 1.8.x before 1.8.16, 1.9.x before 1.9.11, and 1.10.x before 1.10.3 use a hardcoded password for a temporary database user created when running tests with an Oracle database, which makes it easier for remote attackers to obtain access to the database server by leveraging failure to manually specify a password in the database settings TEST dictionary.
An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP.
The trove service user in (1) Openstack deployment (aka crowbar-openstack) and (2) Trove Barclamp (aka barclamp-trove and crowbar-barclamp-trove) in the Crowbar Framework has a default password, which makes it easier for remote attackers to obtain access via unspecified vectors.
Dentsply Sirona (formerly Schick) CDR Dicom 5 and earlier has default passwords for the sa and cdr accounts, which allows remote attackers to obtain administrative access by leveraging knowledge of these passwords.
The rsyncd server in Fortinet FortiWLC 6.1-2-29 and earlier, 7.0-9-1, 7.0-10-0, 8.0-5-0, 8.1-2-0, and 8.2-4-0 has a hardcoded rsync account, which allows remote attackers to read or write to arbitrary files via unspecified vectors.
In SapphireIMS 5.0, it is possible to use the hardcoded credential in clients (username: sapphire, password: ims) and gain access to the portal. Once the access is available, the attacker can inject malicious OS commands on “ping”, “traceroute” and “snmp” functions and execute code on the server.
DEXIS Imaging Suite 10 has a hardcoded password for the sa account, which allows remote attackers to obtain administrative access by entering this password in a DEXIS_DATA SQL Server session.
AVer Information EH6108H+ devices with firmware X9.03.24.00.07l have hardcoded accounts, which allows remote attackers to obtain root access by leveraging knowledge of the credentials and establishing a TELNET session.
VMware Photos OS OVA 1.0 before 2016-08-14 has a default SSH public key in an authorized_keys file, which allows remote attackers to obtain SSH access by leveraging knowledge of the private key.
NUUO NVRmini 2 1.0.0 through 3.0.0 and NUUO NVRsolo 1.0.0 through 3.0.0 have hardcoded root credentials, which allows remote attackers to obtain administrative access via unspecified vectors.
This vulnerability allows remote attackers to bypass authentication on affected installations of Vinchin Backup and Recovery 6.5.0.17561. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the MySQL server. The server uses a hard-coded password for the administrator user. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17139.
A hardcoded password was set for accounts registered using an OmniAuth provider (e.g. OAuth, LDAP, SAML) in GitLab CE/EE versions 14.7 prior to 14.7.7, 14.8 prior to 14.8.5, and 14.9 prior to 14.9.2 allowing attackers to potentially take over accounts
Multiple hardcoded credentials in Xsuite 2.x.
The sample web application in web2py before 2.14.2 might allow remote attackers to execute arbitrary code via vectors involving use of a hardcoded encryption key when calling the session.connect function.
Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.
ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session.
NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration.
Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it.
ZyXEL ZyWALL 1050 has a hard-coded password for the Quagga and Zebra processes that is not changed when it is set by a user, which allows remote attackers to gain privileges.
The Fedora Nagios package uses "nagiosadmin" as the default password for the "nagiosadmin" administrator account, which makes it easier for remote attackers to obtain access by leveraging knowledge of the credentials.
A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way.
Datto ALTO and SIRIS devices have a default VNC password.
iBaby M3S has a password of admin for the backdoor admin account.
D-Link DVG-N5402SP with firmware W1000CN-00, W1000CN-03, or W2000EN-00 has a default password of root for the root account and tw for the tw account, which makes it easier for remote attackers to obtain administrative access.
Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account.
A use of hard-coded password vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to gain access through accounts using default passwords
A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability.
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
The Integrated User Firewall (UserFW) feature was introduced in Junos OS version 12.1X47-D10 on the Juniper SRX Series devices to provide simple integration of user profiles on top of the existing firewall polices. As part of an internal security review of the UserFW services authentication API, hardcoded credentials were identified and removed which can impact both the SRX Series device, and potentially LDAP and Active Directory integrated points. An attacker may be able to completely compromise SRX Series devices, as well as Active Directory servers and services. When Active Directory is compromised, it may allow access to user credentials, workstations, servers performing other functions such as email, database, etc. Inter-Forest Active Directory deployments may also be at risk as the attacker may gain full administrative control over one or more Active Directories depending on the credentials supplied by the administrator of the AD domains and SRX devices performing integrated authentication of users, groups and devices. To identify if your device is potentially vulnerable to exploitation, check to see if the service is operating; from CLI review the following output: root@SRX-Firewall# run show services user-identification active-directory-access domain-controller status extensive A result of "Status: Connected" will indicate that the service is active on the device. To evaluate if user authentication is occurring through the device: root@SRX-Firewall# run show services user-identification active-directory-access active-directory-authentication-table all Next review the results to see if valid users and groups are returned. e.g. Domain: juniperlab.com Total entries: 3 Source IP Username groups state 172.16.26.1 administrator Valid 192.168.26.2 engg01 engineers Valid 192.168.26.3 guest01 guests Valid Domain: NULL Total entries: 8 Source IP Username groups state 192.168.26.4 Invalid 192.168.26.5 Invalid This will also indicate that Valid users and groups are authenticating through the device. Affected releases are Juniper Networks Junos OS 12.3X48 from 12.3X48-D30 and prior to 12.3X48-D35 on SRX series; 15.1X49 from 15.1X49-D40 and prior to 15.1X49-D50 on SRX series. Devices on any version of Junos OS 12.1X46, or 12.1X47 are unaffected by this issue.