D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a command injection vulnerability via the admuser and admpass parameters in /goform/setSysAdm.
D-Link DSL-G2452DG HW:T1\\tFW:ME_2.00 was discovered to contain insecure permissions.
D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a stack overflow via the addhostfilter parameter in /goform/websHostFilter.
D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a stack overflow via the IPADDR and nvmacaddr parameters in /goform/form2Dhcpip.
D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session.
The DHCP client on D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices allows unauthenticated remote code execution as root because /etc/services/INET/inet_ipv4.php mishandles shell metacharacters, affecting generated files such as WAN-1-udhcpc.sh.
D-Link DIR-816 A2_v1.10CNB04 was discovered to contain a stack overflow via the lanip parameter in /goform/setNetworkLan.
register_send.php on D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices does not require authentication, which can result in unintended enrollment in mydlink Cloud Services.
D-Link N300 WI-FI Router DIR-605L v2.13B01 was discovered to contain a stack overflow via the config.smtp_email_subject parameter at /goform/formSetEmail.
D-Link DIR-853 A1 FW1.20B07 was discovered to contain a stack-based buffer overflow vulnerability via the Password parameter in the SetWanSettings module.
A vulnerability has been found in D-Link DIR-816 A2 1.10CNB04 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/setDeviceSettings of the component Web Interface. The manipulation of the argument statuscheckpppoeuser leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252139.
D-Link DIR-100 4.03B07 has PPTP and poe information disclosure
D-Link DIR-600 Rev Bx devices with v2.x firmware allow remote attackers to read passwords via a model/__show_info.php?REQUIRE_FILE= absolute path traversal attack, as demonstrated by discovering the admin password.
An issue in dlink DIR 832x 240802 allows a remote attacker to execute arbitrary code via the macaddr key value to the function 0x42232c
D-Link DIR-615 before v20.12PTb04 has a second admin account with a 0x1 BACKDOOR value, which might allow remote attackers to obtain access via a TELNET connection.
A security issue exists in D-Link D-View 8 v2.0.2.89 and prior that could allow an attacker to manipulate the probe inventory of the D-View service. This could result in the disclosure of information from other probes, denial of service conditions due to the probe inventory becoming full, or the execution of tasks on other probes.
D-Link DIR-820L 1.05B03 was discovered to contain remote command execution (RCE) vulnerability via HTTP POST to get set ccp.
A vulnerability, which was classified as critical, was found in D-Link DAP-1620 1.03. This affects the function check_dws_cookie of the file /storage of the component Cookie Handler. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability has been found in D-Link DAR-7000 up to 20231126 and classified as critical. This vulnerability affects unknown code of the file /user/inc/workidajax.php. The manipulation of the argument id leads to sql injection. The exploit has been disclosed to the public and may be used. VDB-247162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered on D-Link DIR-825 R1 devices through 3.0.1 before 2020-11-20. A buffer overflow in the web interface allows attackers to achieve pre-authentication remote code execution.
In the /HNAP1/SetClientInfoDemo message, the AudioMute and AudioEnable parameters are vulnerable, and the vulnerabilities affect D-Link DIR-868L Rev.B 2.05B02 devices. In the SetClientInfoDemo.php source code, the AudioMute and AudioEnble parameters are saved in the ShellPath script file without any regex checking. After the script file is executed, the command injection occurs. It needs to bypass the wget command option with a single quote. A vulnerable /HNAP1/SetClientInfoDemo XML message could have single quotes and backquotes in the AudioMute or AudioEnable element, such as the '`telnetd`' string.
A vulnerability classified as critical has been found in D-Link DIR-823G 1.0.2B05_20181207. Affected is the function SetDDNSSettings of the file /HNAP1/ of the component DDNS Service. The manipulation of the argument SOAPAction leads to improper authorization. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
D-Link DIR-822 C1 before v3.11B01Beta, DIR-822-US C1 before v3.11B01Beta, DIR-850L A* before v1.21B08Beta, DIR-850L B* before v2.22B03Beta, and DIR-880L A* before v1.20B02Beta devices allow authentication bypass.
An issue was discovered on D-Link DCS-1130 devices. The device provides a user with the capability of setting a SMB folder for the video clippings recorded by the device. It seems that the POST parameters passed in this request (to test if email credentials and hostname sent to the device work properly) result in being passed as commands to a "system" API in the function and thus result in command injection on the device. If the firmware version is dissected using binwalk tool, we obtain a cramfs-root archive which contains the filesystem set up on the device that contains all the binaries. The library "libmailutils.so" is the one that has the vulnerable function "sub_1FC4" that receives the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows an ARM little endian format. The function sub_1FC4 in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "receiver1" is extracted in function "sub_15AC" which is then passed to the vulnerable system API call. The vulnerable library function is accessed in "cgibox" binary at address 0x0008F598 which calls the "mailLoginTest" function in "libmailutils.so" binary as shown below which results in the vulnerable POST parameter being passed to the library which results in the command injection issue.
D-Link DCM-604 DCM604_C1_ViaCabo_1.04_20130606 and DCM-704 EU_DCM-704_1.10 devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.4413.2.2.2.1.5.4.1.14.1.3.32 and iso.3.6.1.4.1.4413.2.2.2.1.5.4.2.4.1.2.32 SNMP requests.
Stack-based buffer overflow in the Universal Plug and Play (UPnP) service in D-Link DI-524, DI-604 Broadband Router, DI-624, D-Link DI-784, WBR-1310 Wireless G Router, WBR-2310 RangeBooster G Router, and EBR-2310 Ethernet Broadband Router allows remote attackers to execute arbitrary code via a long M-SEARCH request to UDP port 1900.
D-Link COVR-2600R and COVR-3902 Kit before 1.01b05Beta01 use hardcoded credentials for telnet connection, which allows unauthenticated attackers to gain privileged access to the router, and to extract sensitive data or modify the configuration.
An issue discovered in D-Link dir815 v.1.01SSb08.bin allows a remote attacker to execute arbitrary code via a crafted POST request to the service parameter in the soapcgi_main function of the cgibin binary component.
D-Link DIR-822+ V1.0.2 contains a login bypass in the HNAP1 interface, which allows attackers to log in to administrator accounts with empty passwords.
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, has been found in D-Link DAR-7000 up to 20151231. This issue affects some unknown processing of the file /log/webmailattach.php. The manipulation of the argument table_name leads to an unknown weakness. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-240239. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
An issue in D-Link DWR-M972V 1.05SSG allows a remote attacker to execute arbitrary code via SSH using root account without restrictions
Use of a static key to protect a JWT token used in user authentication can allow an for an authentication bypass in D-Link D-View 8 v2.0.1.28
An issue in D-Link DIR-850L v.B1_FW223WWb01 allows a remote attacker to execute arbitrary code via a crafted script to the en parameter.
D-Link Go-RT-AC750 revA_v101b03 was discovered to contain a command injection vulnerability via the service parameter at hedwig.cgi.
A Command Injection vulnerability exists in the /var/www/cgi-bin/rtpd.cgi script in D-Link IP Cameras DCS-3411/3430 firmware 1.02, DCS-5605/5635 1.01, DCS-1100L/1130L 1.04, DCS-1100/1130 1.03, DCS-1100/1130 1.04_US, DCS-2102/2121 1.05_RU, DCS-3410 1.02, DCS-5230 1.02, DCS-5230L 1.02, DCS-6410 1.00, DCS-7410 1.00, DCS-7510 1.00, and WCS-1100 1.02, which could let a remote malicious user execute arbitrary commands through the camera’s web interface.
atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials.
On D-Link DIR-823G devices, ExportSettings.sh, upload_settings.cgi, GetDownLoadSyslog.sh, and upload_firmware.cgi do not require authentication, which allows remote attackers to execute arbitrary code.
An issue was discovered on D-Link DVA-5592 A1_WI_20180823 devices. If the PIN of the page "/ui/cbpc/login" is the default Parental Control PIN (0000), it is possible to bypass the login form by editing the path of the cookie "sid" generated by the page. The attacker will have access to the router control panel with administrator privileges.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a stack overflow via the id parameter in the yyxz.data function.
On D-Link DIR-823G devices, the GoAhead configuration allows /HNAP1 Command Injection via shell metacharacters in the POST data, because this data is sent directly to the "system" library function.
D-Link DIR-823G v1.0.2B05 was discovered to contain a stack overflow via parameter TXPower and GuardInt in SetWLanRadioSecurity.
D-LINK DWL-6610 FW_v_4.3.0.8B003C was discovered to contain a command injection vulnerability in the function web_cert_download_handler. This vulnerability allows attackers to execute arbitrary commands via the certDownload parameter.
dirary0.js on D-Link DIR-140L, DIR-640L devices allows remote unauthenticated attackers to discover admin credentials.
An issue was discovered on D-Link Central WiFi Manager before v 1.03r0100-Beta1. They expose an FTP server that serves by default on port 9000 and has hardcoded credentials (admin, admin). Taking advantage of this, a remote unauthenticated attacker could execute arbitrary PHP code by uploading any file in the web root directory and then accessing it via a request.
Stack Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the ip parameter of the ip_position.asp function.
A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Buffer Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the fn parameter of the tgfile.htm function.
Buffer Overflow vulnerability in D-Link device DI-7003GV2.D1 v.23.08.25D1 and before, DI-7100G+V2.D1 v.23.08.23D1 and before, DI-7100GV2.D1 v.23.08.23D1, DI-7200G+V2.D1 v.23.08.23D1 and before, DI-7200GV2.E1 v.23.08.23E1 and before, DI-7300G+V2.D1 v.23.08.23D1, and DI-7400G+V2.D1 v.23.08.23D1 and before allows a remote attacker to execute arbitrary code via the fn parameter of the file.data function.
D-Link DIR-619L B1 2.02 is vulnerable to Buffer Overflow via formSetWAN_Wizard56 function.
D-Link DIR-615 devices have a buffer overflow via a long Authorization HTTP header.