Vulnerability Details :

CVE-2017-6183

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-30 Mar, 2017 | 17:00
Updated At-05 Aug, 2024 | 15:25
Rejected At-
Credits

In Sophos Web Appliance (SWA) before 4.3.1.2, a section of the machine's configuration utilities for adding (and detecting) Active Directory servers was vulnerable to remote command injection, aka NSWA-1314.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:30 Mar, 2017 | 17:00
Updated At:05 Aug, 2024 | 15:25
Rejected At:
▼CVE Numbering Authority (CNA)

In Sophos Web Appliance (SWA) before 4.3.1.2, a section of the machine's configuration utilities for adding (and detecting) Active Directory servers was vulnerable to remote command injection, aka NSWA-1314.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
x_refsource_CONFIRM
http://www.securityfocus.com/bid/97261
vdb-entry
x_refsource_BID
https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
x_refsource_CONFIRM
Hyperlink: http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
Resource:
x_refsource_CONFIRM
Hyperlink: http://www.securityfocus.com/bid/97261
Resource:
vdb-entry
x_refsource_BID
Hyperlink: https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
x_refsource_CONFIRM
x_transferred
http://www.securityfocus.com/bid/97261
vdb-entry
x_refsource_BID
x_transferred
https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
x_refsource_CONFIRM
x_transferred
Hyperlink: http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
Resource:
x_refsource_CONFIRM
x_transferred
Hyperlink: http://www.securityfocus.com/bid/97261
Resource:
vdb-entry
x_refsource_BID
x_transferred
Hyperlink: https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:30 Mar, 2017 | 17:59
Updated At:20 Apr, 2025 | 01:37

In Sophos Web Appliance (SWA) before 4.3.1.2, a section of the machine's configuration utilities for adding (and detecting) Active Directory servers was vulnerable to remote command injection, aka NSWA-1314.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.07.2HIGH
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.0
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

Sophos Ltd.
sophos
>>web_appliance>>Versions up to 4.3.1.1(inclusive)
cpe:2.3:a:sophos:web_appliance:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.htmlcve@mitre.org
Release Notes
Vendor Advisory
http://www.securityfocus.com/bid/97261cve@mitre.org
N/A
https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2cve@mitre.org
Vendor Advisory
http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.htmlaf854a3a-2127-422b-91ae-364da2661108
Release Notes
Vendor Advisory
http://www.securityfocus.com/bid/97261af854a3a-2127-422b-91ae-364da2661108
N/A
https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
Hyperlink: http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
Source: cve@mitre.org
Resource:
Release Notes
Vendor Advisory
Hyperlink: http://www.securityfocus.com/bid/97261
Source: cve@mitre.org
Resource: N/A
Hyperlink: https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
Source: cve@mitre.org
Resource:
Vendor Advisory
Hyperlink: http://wsa.sophos.com/rn/swa/concepts/ReleaseNotes_4.3.1.2.html
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Release Notes
Vendor Advisory
Hyperlink: http://www.securityfocus.com/bid/97261
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: https://community.sophos.com/products/web-appliance/b/blog/posts/release-of-swa-v4-3-1-2
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

356Records found

CVE-2015-8988
Matching Score-4
Assigner-Intel Corporation
ShareView Details
Matching Score-4
Assigner-Intel Corporation
CVSS Score-8.8||HIGH
EPSS-0.58% / 68.02%
||
7 Day CHG~0.00%
Published-14 Mar, 2017 | 22:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Unquoted executable path vulnerability in Client Management and Gateway components in McAfee (now Intel Security) ePO Deep Command (eDC) 2.2 and 2.1 allows authenticated users to execute a command of their choice via dropping a malicious file for the path.

Action-Not Available
Vendor-McAfee, LLCIntel Corporation
Product-epo_deep_commandePO Deep Command (eDC)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-8197
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-7.2||HIGH
EPSS-1.91% / 82.57%
||
7 Day CHG~0.00%
Published-22 Nov, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

FusionSphere V100R006C00SPC102(NFV) has a command injection vulnerability. An authenticated, remote attacker could craft packets with malicious strings and send them to a target device. Successful exploit could allow the attacker to launch a command injection attack and execute system commands.

Action-Not Available
Vendor-Huawei Technologies Co., Ltd.
Product-fusionsphereFusionSphere
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-12786
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.49% / 84.72%
||
7 Day CHG~0.00%
Published-10 Jun, 2019 | 17:49
Updated-04 Aug, 2024 | 23:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on D-Link DIR-818LW devices from 2.05.B03 to 2.06B01 BETA. There is a command injection in HNAP1 SetWanSettings via an XML injection of the value of the IPAddress key.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-818lw_firmwaredir-818lwn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-26085
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-2.67% / 85.25%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability exists in the httpd wlscan_ASP functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24390
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.80% / 73.07%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:27
Updated-16 Sep, 2024 | 16:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “remote_text_file” enables an attacker with user level access to the CLI to inject user level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-12591
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.84% / 73.84%
||
7 Day CHG~0.00%
Published-03 Jun, 2019 | 12:35
Updated-04 Aug, 2024 | 23:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETGEAR Insight Cloud with firmware before Insight 5.6 allows remote authenticated users to achieve command injection.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-insightn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-6327
Matching Score-4
Assigner-Symantec - A Division of Broadcom
ShareView Details
Matching Score-4
Assigner-Symantec - A Division of Broadcom
CVSS Score-8.8||HIGH
EPSS-85.20% / 99.31%
||
7 Day CHG~0.00%
Published-11 Aug, 2017 | 20:00
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2022-05-03||Apply updates per vendor instructions.

The Symantec Messaging Gateway before 10.6.3-267 can encounter an issue of remote code execution, which describes a situation whereby an individual may obtain the ability to execute commands remotely on a target machine or in a target process. In this type of occurrence, after gaining access to the system, the attacker may attempt to elevate their privileges.

Action-Not Available
Vendor-Symantec Corporation
Product-message_gatewayMessaging GatewaySymantec Messaging Gateway
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-13150
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.84% / 89.12%
||
7 Day CHG~0.00%
Published-02 Jul, 2019 | 12:16
Updated-04 Aug, 2024 | 23:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in TRENDnet TEW-827DRU firmware before 2.05B11. There is a command injection in apply.cgi (exploitable with authentication). The command injection exists in the key ip_addr.

Action-Not Available
Vendor-n/aTRENDnet, Inc.
Product-tew-827dru_firmwaretew-827drun/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-13552
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.58% / 80.84%
||
7 Day CHG~0.00%
Published-18 Sep, 2019 | 21:00
Updated-04 Aug, 2024 | 23:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In WebAccess versions 8.4.1 and prior, multiple command injection vulnerabilities are caused by a lack of proper validation of user-supplied data and may allow arbitrary file deletion and remote code execution.

Action-Not Available
Vendor-n/aAdvantech (Advantech Co., Ltd.)
Product-webaccessWebAccess
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-11279
Matching Score-4
Assigner-VMware by Broadcom
ShareView Details
Matching Score-4
Assigner-VMware by Broadcom
CVSS Score-8.7||HIGH
EPSS-0.49% / 64.68%
||
7 Day CHG~0.00%
Published-26 Sep, 2019 | 21:15
Updated-17 Sep, 2024 | 02:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Privilege Escalation via Scope Manipulation in UAA

CF UAA versions prior to 74.1.0 can request scopes for a client that shouldn't be allowed by submitting an array of requested scopes. A remote malicious user can escalate their own privileges to any scope, allowing them to take control of UAA and the resources it controls.

Action-Not Available
Vendor-Cloud Foundry
Product-uaa_releaseUAA Release (OSS)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-11853
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-3.9||LOW
EPSS-0.02% / 4.23%
||
7 Day CHG~0.00%
Published-21 Aug, 2020 | 18:52
Updated-17 Sep, 2024 | 03:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ALEOS AT Command Injections

Several potential command injections vulnerabilities exist in the AT command interface of ALEOS before 4.11.0, and 4.9.4.

Action-Not Available
Vendor-sierrawirelessn/a
Product-airlink_lx60aleosairlink_rv50airlink_mp70eairlink_gx450airlink_lx40airlink_es450airlink_rv50xairlink_mp70n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2017-4054
Matching Score-4
Assigner-Intel Corporation
ShareView Details
Matching Score-4
Assigner-Intel Corporation
CVSS Score-8.8||HIGH
EPSS-4.29% / 88.41%
||
7 Day CHG~0.00%
Published-12 Jul, 2017 | 15:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command Injection vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote authenticated users to execute a command of their choice via a crafted HTTP request parameter.

Action-Not Available
Vendor-McAfee, LLC
Product-advanced_threat_defenseAdvanced Threat Defense (ATD)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-12430
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.67% / 87.42%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 13:40
Updated-04 Aug, 2024 | 23:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in GitLab Community and Enterprise Edition 11.11. A specially crafted payload would allow an authenticated malicious user to execute commands remotely through the repository download feature. It allows Command Injection.

Action-Not Available
Vendor-n/aGitLab Inc.
Product-gitlabn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-11278
Matching Score-4
Assigner-VMware by Broadcom
ShareView Details
Matching Score-4
Assigner-VMware by Broadcom
CVSS Score-8.7||HIGH
EPSS-0.45% / 62.50%
||
7 Day CHG~0.00%
Published-26 Sep, 2019 | 21:11
Updated-16 Sep, 2024 | 23:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Privilege Escalation via Blind SCIM Injection in UAA

CF UAA versions prior to 74.1.0, allow external input to be directly queried against. A remote malicious user with 'client.write' and 'groups.update' can craft a SCIM query, which leaks information that allows an escalation of privileges, ultimately allowing the malicious user to gain control of UAA scopes they should not have.

Action-Not Available
Vendor-Cloud Foundry
Product-user_account_and_authenticationUAA Release (OSS)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-4414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-4.92% / 89.20%
||
7 Day CHG~0.00%
Published-18 Aug, 2023 | 16:00
Updated-21 Nov, 2024 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Byzoro Smart S85F Management Platform decodmail.php command injection

A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230807. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /log/decodmail.php. The manipulation of the argument file leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-237517 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-byzoroByzoro
Product-smart_s85fSmart S85F Management Platform
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-18885
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-1.66% / 81.34%
||
7 Day CHG~0.00%
Published-20 Aug, 2021 | 13:22
Updated-04 Aug, 2024 | 14:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command Injection in PHPMyWind v5.6 allows remote attackers to execute arbitrary code via the "text color" field of the component '/admin/web_config.php'.

Action-Not Available
Vendor-phpmywindn/a
Product-phpmywindn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-11770
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-1.07% / 76.89%
||
7 Day CHG~0.00%
Published-15 Apr, 2020 | 13:47
Updated-04 Aug, 2024 | 11:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6220 before 1.0.0.52, D6400 before 1.0.0.86, D7000v2 before 1.0.0.53, D8500 before 1.0.3.44, R6220 before 1.1.0.80, R6250 before 1.0.4.34, R6260 before 1.1.0.64, R6400 before 1.0.1.46, R6400v2 before 1.0.2.66, R6700 before 1.0.2.6, R6700v2 before 1.2.0.36, R6700v3 before 1.0.2.66, R6800 before 1.2.0.36, R6900 before 1.0.2.4, R6900P before 1.3.1.64, R6900v2 before 1.2.0.36, R7000 before 1.0.9.42, R7000P before 1.3.1.64, R7100LG before 1.0.0.50, R7300DST before 1.0.0.70, R7800 before 1.0.2.60, R7900 before 1.0.3.8, R7900P before 1.4.1.30, R8000 before 1.0.4.28, R8000P before 1.4.1.30, R8300 before 1.0.2.128, R8500 before 1.0.2.128, R8900 before 1.0.4.12, R9000 before 1.0.4.12, and XR500 before 2.3.2.32.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r8900_firmwarer6220_firmwarer8000r6400_firmwarer6900pr7100lgr7900r8000pr6900p_firmwared6220r6800r7100lg_firmwarer7300dst_firmwarer8300r8500_firmwarer6260_firmwarer6260r7000_firmwarer6220r8000p_firmwared6400_firmwarexr500_firmwarer7300dstd6220_firmwared8500_firmwarer6250_firmwarer7900pxr500r7000p_firmwarer8500d7000r8900r9000_firmwared8500d7000_firmwarer6700r8300_firmwarer7000r6900d6400r7000pr9000r6900_firmwarer7800r7900_firmwarer7800_firmwarer6400r6700_firmwarer7900p_firmwarer6800_firmwarer8000_firmwarer6250n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2013-7418
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-3.89% / 87.80%
||
7 Day CHG~0.00%
Published-02 Jan, 2015 | 22:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

cgi-bin/iptablesgui.cgi in IPCop (aka IPCop Firewall) before 2.1.5 allows remote authenticated users to execute arbitrary code via shell metacharacters in the TABLE parameter. NOTE: this can be exploited remotely by leveraging a separate cross-site scripting (XSS) vulnerability.

Action-Not Available
Vendor-ipcopn/a
Product-ipcopn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-22688
Matching Score-4
Assigner-Synology Inc.
ShareView Details
Matching Score-4
Assigner-Synology Inc.
CVSS Score-8.8||HIGH
EPSS-2.18% / 83.68%
||
7 Day CHG~0.00%
Published-25 Mar, 2022 | 06:55
Updated-14 Jan, 2025 | 19:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper neutralization of special elements used in a command ('Command Injection') vulnerability in File service functionality in Synology DiskStation Manager (DSM) before 6.2.4-25556-2 allows remote authenticated users to execute arbitrary commands via unspecified vectors.

Action-Not Available
Vendor-Synology, Inc.
Product-diskstation_managerDiskStation Manager (DSM)
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2015-5274
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.62% / 69.15%
||
7 Day CHG~0.00%
Published-18 Sep, 2015 | 14:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

rubygem-openshift-origin-console in Red Hat OpenShift 2.2 allows remote authenticated users to execute arbitrary commands via a crafted request to the Broker.

Action-Not Available
Vendor-n/aRed Hat, Inc.
Product-openshiftn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2015-0934
Matching Score-4
Assigner-CERT/CC
ShareView Details
Matching Score-4
Assigner-CERT/CC
CVSS Score-6.5||MEDIUM
EPSS-1.25% / 78.48%
||
7 Day CHG~0.00%
Published-04 Mar, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Common LaTeX Service Interface (CLSI) before 0.1.3, as used in ShareLaTeX before 0.1.3, allows remote authenticated users to execute arbitrary code via ` (backtick) characters in a filename.

Action-Not Available
Vendor-sharelatexn/a
Product-sharelatexn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2015-4336
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-1.46% / 80.05%
||
7 Day CHG~0.00%
Published-17 Jun, 2015 | 18:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

cloner.functions.php in the XCloner plugin 3.1.2 for WordPress allows remote authenticated users to execute arbitrary commands via a file containing filenames with shell metacharacters, as demonstrated by using the backup comments feature to create the file.

Action-Not Available
Vendor-xclonern/a
Product-xclonern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2015-4046
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-6.20% / 90.49%
||
7 Day CHG~0.00%
Published-23 May, 2017 | 03:56
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The asset discovery scanner in AlienVault OSSIM before 5.0.1 allows remote authenticated users to execute arbitrary commands via the assets array parameter to netscan/do_scan.php.

Action-Not Available
Vendor-alienvaultn/a
Product-open_source_security_information_managementn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-1456
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.15% / 35.66%
||
7 Day CHG~0.00%
Published-25 Mar, 2023 | 00:00
Updated-02 Aug, 2024 | 05:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability, which was classified as critical, has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. This issue affects some unknown processing of the component NAT Configuration Handler. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier VDB-223301 was assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgerouter_x_firmwareedgerouter_xEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2014-8630
Matching Score-4
Assigner-Mozilla Corporation
ShareView Details
Matching Score-4
Assigner-Mozilla Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.62% / 69.08%
||
7 Day CHG~0.00%
Published-01 Feb, 2015 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Bugzilla before 4.0.16, 4.1.x and 4.2.x before 4.2.12, 4.3.x and 4.4.x before 4.4.7, and 5.x before 5.0rc1 allows remote authenticated users to execute arbitrary commands by leveraging the editcomponents privilege and triggering crafted input to a two-argument Perl open call, as demonstrated by shell metacharacters in a product name.

Action-Not Available
Vendor-n/aMozilla CorporationFedora Project
Product-fedorabugzillan/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2014-8903
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-8.8||HIGH
EPSS-0.85% / 73.97%
||
7 Day CHG~0.00%
Published-02 Aug, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Curam Social Program Management 6.0 SP2 before EP26, 6.0.4 before 6.0.4.5iFix10 and 6.0.5 before 6.0.5.6 allows remote authenticated users to load arbitrary Java classes via unspecified vectors.

Action-Not Available
Vendor-n/aIBM Corporation
Product-curam_social_program_managementn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-7826
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.05% / 76.66%
||
7 Day CHG-0.06%
Published-22 May, 2019 | 19:33
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-7825
Matching Score-4
Assigner-Schneider Electric
ShareView Details
Matching Score-4
Assigner-Schneider Electric
CVSS Score-8.8||HIGH
EPSS-1.05% / 76.66%
||
7 Day CHG-0.06%
Published-22 May, 2019 | 19:32
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in the web-based GUI of the 1st Gen PelcoSarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands.

Action-Not Available
Vendor-n/a
Product-ime219-1ep_firmwareime119-1esime319-1ei_firmwareime219-1vi_firmwareime3122-1vp_firmwareime219-1vs_firmwareime319-1vs_firmwareime219-1esd6220ime219-1vp_firmwareixe31imes19-1eiime3122-1vpimes19-1sime3122-1epime219-1viimes19-1esime319-1eiime3122-1iimes19-1ep_firmwareimes19-1es_firmwared6220_firmwareime3122-b1iimes19-1s_firmwareime3122-b1s_firmwareime119-1vi_firmwared6230_firmwareime319-1s_firmwareime319-b1p_firmwareime319-1pime3122-b1pime319-1ep_firmwareime319-1vsime119-1vp_firmwareime219-1vpime219-1iime3122-1esixe21_firmwareime319-1p_firmwareime3122-1i_firmwareime319-1viimes19-1vsime119-1viimes19-1vp_firmwareime119-1pime3122-1vs_firmwareime219-1es_firmwareime319-1vpimes19-1vpime3122-1eiime319-b1s_firmwareimes19-1ei_firmwareime119-1ei_firmwareime219-1pixe11_firmwareime3122-1ei_firmwareime119-1vpime319-b1iixe31_firmwareime119-1vs_firmwareixes1ime219-1p_firmwareime3122-1ep_firmwareime3122-1vi_firmwareime219-1s_firmwareime119-1vsime119-1es_firmwareimes19-1epime219-1epime319-1vi_firmwareime119-1i_firmwareime119-1eiime319-1iimes19-1iime319-b1sime3122-1p_firmwareimes19-1vi_firmwareimes19-1vs_firmwareime3122-1sime119-1iimes19-1viimes19-1i_firmwareime319-1vp_firmwareime319-1i_firmwareimes19-1pime219-1sime319-b1i_firmwareime3122-1s_firmwareime219-1i_firmwareime3122-1viixe21d6230lime119-1p_firmwareime219-1eiime319-1es_firmwared6230l_firmwareime319-b1pime319-1esd6230ime3122-b1sime219-1ei_firmwareime119-1epd6220lime3122-1vsime219-1vsimes19-1p_firmwareime319-1epime3122-1es_firmwareime119-1sime119-1ep_firmwared6220l_firmwareixes1_firmwareime3122-b1i_firmwareime3122-b1p_firmwareime319-1sixe11ime119-1s_firmwareime3122-1pPelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9727
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.63% / 69.41%
||
7 Day CHG~0.00%
Published-31 Aug, 2025 | 11:32
Updated-31 Aug, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-816L soap.cgi soapcgi_main os command injection

A weakness has been identified in D-Link DIR-816L 206b01. Affected by this issue is the function soapcgi_main of the file /soap.cgi. This manipulation of the argument service causes os command injection. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be exploited. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-816L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9582
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.06% / 76.75%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 19:32
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt ntp_timezone command injection

A flaw has been found in Comfast CF-N1 2.6.0. Affected is the function ntp_timezone of the file /usr/bin/webmgnt. Executing manipulation of the argument timestr can lead to command injection. The attack may be launched remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-Comfast
Product-CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8818
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.36%
||
7 Day CHG~0.00%
Published-10 Aug, 2025 | 22:32
Updated-12 Aug, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setLan setDFSSetting os command injection

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setDFSSetting of the file /goform/setLan. The manipulation of the argument lanNetmask/lanIp leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9654
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.86% / 74.06%
||
7 Day CHG~0.00%
Published-29 Aug, 2025 | 15:02
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
AiondaDotCom mcp-ssh server-simple.mjs command injection

A security flaw has been discovered in AiondaDotCom mcp-ssh up to 1.0.3. Affected by this issue is some unknown functionality of the file server-simple.mjs. Performing manipulation results in command injection. The attack can be initiated remotely. Upgrading to version 1.0.4 and 1.1.0 can resolve this issue. The patch is named cd2566a948b696501abfa6c6b03462cac5fb43d8. It is advisable to upgrade the affected component.

Action-Not Available
Vendor-AiondaDotCom
Product-mcp-ssh
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9581
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.06% / 76.75%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 19:02
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt multi_pppoe command injection

A vulnerability was detected in Comfast CF-N1 2.6.0. This impacts the function multi_pppoe of the file /usr/bin/webmgnt. Performing manipulation of the argument phy_interface results in command injection. The attack may be initiated remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Comfast
Product-CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9244
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.43% / 79.90%
||
7 Day CHG+0.36%
Published-20 Aug, 2025 | 19:32
Updated-22 Aug, 2025 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 addStaticRoute os command injection

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaticRoute of the file /goform/addStaticRoute. Such manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting/staticRoute_destType_setting leads to os command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE9000RE6250RE6350RE6300RE6500
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8667
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.43% / 79.90%
||
7 Day CHG~0.00%
Published-06 Aug, 2025 | 18:02
Updated-06 Aug, 2025 | 20:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SkyworkAI DeepResearchAgent tools.py from_mcp os command injection

A vulnerability, which was classified as critical, was found in SkyworkAI DeepResearchAgent up to 08eb7f8eb9505d0094d75bb97ff7dacc3fa3bbf2. Affected is the function from_code/from_dict/from_mcp of the file src/tools/tools.py. The manipulation leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-SkyworkAI
Product-DeepResearchAgent
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8697
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.43% / 79.90%
||
7 Day CHG~0.00%
Published-07 Aug, 2025 | 19:02
Updated-07 Aug, 2025 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
agentUniverse MCPSessionManager/MCPTool/MCPToolkit StdioServerParameters os command injection

A vulnerability was found in agentUniverse up to 0.0.18 and classified as critical. This issue affects the function StdioServerParameters of the component MCPSessionManager/MCPTool/MCPToolkit. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-n/a
Product-agentUniverse
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9090
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-9.02% / 92.30%
||
7 Day CHG~0.00%
Published-17 Aug, 2025 | 02:02
Updated-21 Aug, 2025 | 16:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC20 Telnet Service telnet websFormDefine command injection

A vulnerability was identified in Tenda AC20 16.03.08.12. Affected is the function websFormDefine of the file /goform/telnet of the component Telnet Service. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac20ac20_firmwareAC20
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9580
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.08% / 76.94%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 19:02
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK BL-X26 HTTP set_blacklist os command injection

A security vulnerability has been detected in LB-LINK BL-X26 1.2.8. This affects an unknown function of the file /goform/set_blacklist of the component HTTP Handler. Such manipulation of the argument mac leads to os command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-LB-LINK
Product-BL-X26
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8827
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.36%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:02
Updated-12 Aug, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8937
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-4.18% / 88.26%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 04:32
Updated-15 Aug, 2025 | 21:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N350R formSysCmd command injection

A vulnerability has been found in TOTOLINK N350R 1.2.3-B20130826. This vulnerability affects unknown code of the file /boafrm/formSysCmd. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-N350R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9584
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.06% / 76.75%
||
7 Day CHG~0.00%
Published-Not Available
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability was found in Comfast CF-N1 2.6.0. Affected by this issue is the function update_interface_png of the file /usr/bin/webmgnt. The manipulation of the argument interface/display_name results in command injection. The attack can be executed remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-
Product-
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8829
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.36%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 04:02
Updated-12 Aug, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_red os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function um_red of the file /goform/RP_setBasicAuto. The manipulation of the argument hname leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9149
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.43% / 79.90%
||
7 Day CHG+0.36%
Published-19 Aug, 2025 | 17:32
Updated-20 Aug, 2025 | 14:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-NU516U1 wireless.cgi sub_4032E4 command injection

A vulnerability was determined in Wavlink WL-NU516U1 M16U1_V240425. This impacts the function sub_4032E4 of the file /cgi-bin/wireless.cgi. This manipulation of the argument Guest_ssid causes command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-WL-NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8956
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.09% / 26.25%
||
7 Day CHG~0.00%
Published-14 Aug, 2025 | 10:02
Updated-18 Aug, 2025 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR‑818L ssdpcgi cgibin getenv command injection

A vulnerability was found in D-Link DIR‑818L up to 1.05B01. This issue affects the function getenv of the file /htdocs/cgibin of the component ssdpcgi. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-818l_firmwaredir-818lDIR‑818L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-1819
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.28% / 50.74%
||
7 Day CHG~0.00%
Published-02 Mar, 2025 | 16:31
Updated-16 Jul, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 1200M telnet TendaTelnet os command injection

A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7 1200M
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9575
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.92% / 75.09%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 18:02
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 upload.cgi cgiMain os command injection

A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function cgiMain of the file /cgi-bin/upload.cgi. Executing manipulation of the argument filename can lead to os command injection. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE6500RE9000RE7000RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8825
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.23% / 78.36%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 02:02
Updated-12 Aug, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulation of the argument staticIp/staticNetmask leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9583
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.84% / 73.80%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 20:02
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt ping_config command injection

A vulnerability has been found in Comfast CF-N1 2.6.0. Affected by this vulnerability is the function ping_config of the file /usr/bin/webmgnt. The manipulation leads to command injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Comfast
Product-CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9586
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.06% / 76.75%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 21:02
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt wireless_device_dissoc command injection

A vulnerability was identified in Comfast CF-N1 2.6.0. This vulnerability affects the function wireless_device_dissoc of the file /usr/bin/webmgnt. Such manipulation of the argument mac leads to command injection. The attack may be performed from a remote location. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Comfast
Product-CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9585
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.06% / 76.75%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 20:32
Updated-29 Aug, 2025 | 16:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Comfast CF-N1 webmgnt wifilith_delete_pic_file command injection

A vulnerability was determined in Comfast CF-N1 2.6.0. This affects the function wifilith_delete_pic_file of the file /usr/bin/webmgnt. This manipulation of the argument portal_delete_picname causes command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Comfast
Product-CF-N1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')