Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 have Cassandra service enabled by default with hardcoded credentials. These credentials allow network based attackers unauthorized access to information stored in Cassandra.
Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 use hardcoded credentials to access Keystone service. These credentials allow network based attackers unauthorized access to information stored in keystone.
Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account.
Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices have default credentials that are hardcoded in the firmware and can be extracted by anyone who reverses the firmware to identify them. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable function that sets up the default credentials on the device. If one opens this binary in IDA-pro, one will notice that this follows a ARM little endian format. The function sub_3DB2FC in IDA pro is identified to be setting up the values at address 0x003DB5A6. The sub_5C057C then sets this value and adds it to the Configuration files in /mnt/mtd/Config/Account1 file.
Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET.
Inim Electronics Smartliving SmartLAN/G/SI <=6.x uses default hardcoded credentials. An attacker could exploit this to gain Telnet, SSH and FTP access to the system.
On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root"). The attacker can make a user that is connected to the repeater click on a malicious link that will log into the telnet and will infect the device with malicious code.
Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.
Multiple hardcoded credentials in Xsuite 2.x.
The server API in the Anda app relies on hardcoded credentials.
Intellinet NFC-30ir IP Camera has a vendor backdoor that can allow a remote attacker access to a vendor-supplied CGI script in the web directory.
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
A design flaw in the Trane ComfortLink II SCC firmware version 2.0.2 service allows remote attackers to take complete control of the system.
Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account.
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
Lens Peek-a-View has a password of 2601hx for the backdoor admin account, a password of user for the backdoor user account, and a password of guest for the backdoor guest account.
iBaby M3S has a password of admin for the backdoor admin account.
A hard-coded cryptographic key vulnerability in the default configuration file was found in Kiali, all versions prior to 1.15.1. A remote attacker could abuse this flaw by creating their own JWT signed tokens and bypass Kiali authentication mechanisms, possibly gaining privileges to view and alter the Istio configuration.
An issue was discovered on Intelbras NCLOUD 300 1.0 devices. /cgi-bin/ExportSettings.sh, /goform/updateWPS, /goform/RebootSystem, and /goform/vpnBasicSettings do not require authentication. For example, when an HTTP POST request is made to /cgi-bin/ExportSettings.sh, the username, password, and other details are retrieved.
/usr/lib/lua/luci/websys.lua on TP-LINK IPC TL-IPC223(P)-6, TL-IPC323K-D, TL-IPC325(KP)-*, and TL-IPC40A-4 devices has a hardcoded zMiVw8Kw0oxKXL0 password.
Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They contain two undocumented administrator accounts. The sftp and mofidev accounts are defined in /etc/passwd and the password is not unique across installations.
Denbun by NEOJAPAN Inc. (Denbun POP version V3.3P R4.0 and earlier, Denbun IMAP version V3.3I R4.0 and earlier) uses hard-coded credentials, which may allow remote attackers to login to the Management page and change the configuration.
The Web Panel in Netsweeper before 4.0.5 has a default password of branding for the branding account, which makes it easier for remote attackers to obtain access via a request to webadmin/.
Denbun by NEOJAPAN Inc. (Denbun POP version V3.3P R4.0 and earlier, Denbun IMAP version V3.3I R4.0 and earlier) uses hard-coded credentials, which may allow remote attackers to read/send mail or change the configuration.
Juniper Networks Contrail Service Orchestrator versions prior to 4.0.0 use hardcoded cryptographic certificates and keys in some cases, which may allow network based attackers to gain unauthorized access to services.
A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials.
TRENDnet TEW-823DRU devices with firmware before 1.00b36 have a hardcoded password of kcodeskcodes for the root account, which makes it easier for remote attackers to obtain access via an FTP session.
The National Payments Corporation of India BHIM application 1.3 for Android relies on three hardcoded strings (AK-NPCIMB, IM-NPCIBM, and VK-NPCIBM) for SMS validation, which makes it easier for attackers to bypass authentication.
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.
A Use of Password Hash Instead of Password for Authentication issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-IPC-HDW4XXX, DH-IPC-HFW1XXX, DH-IPC-HFW2XXX, DH-IPC-HFW4XXX, DH-SD6CXX, DH-NVR1XXX, DH-HCVR4XXX, DH-HCVR5XXX, DHI-HCVR51A04HE-S3, DHI-HCVR51A08HE-S3, and DHI-HCVR58A32S-S2 devices. The use of password hash instead of password for authentication vulnerability was identified, which could allow a malicious user to bypass authentication without obtaining the actual password.
Softing FG-100 PB PROFIBUS firmware version FG-x00-PB_V2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session.
Telesquare SDT-CS3B1 and SDT-CW3B1 devices through 1.2.0 have a default factory account. Remote attackers can obtain access to the device via TELNET using a hardcoded account.
On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not).
EMC Data Protection Advisor 6.3.x before patch 67 and 6.4.x before patch 130 contains undocumented accounts with hard-coded passwords and various privileges. Affected accounts are: "Apollo System Test", "emc.dpa.agent.logon" and "emc.dpa.metrics.logon". An attacker with knowledge of the password could potentially use these accounts via REST APIs to gain unauthorized access to EMC Data Protection Advisor (including potentially access with administrative privileges).
DragonWave Horizon 1.01.03 wireless radios have hardcoded login credentials (such as the username of energetic and password of wireless) meant to allow the vendor to access the devices. These credentials can be used in the web interface or by connecting to the device via TELNET. This is fixed in recent versions including 1.4.8.
A hard-coded account named 'upgrade' in Fortinet FortiWLM 8.3.0 and lower versions allows a remote attacker to log-in and execute commands with 'upgrade' account privileges.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.
In some circumstances, an F5 BIG-IP version 12.0.0 to 12.1.2 and 13.0.0 Azure cloud instance may contain a default administrative password which could be used to remotely log into the BIG-IP system. The impacted administrative account is the Azure instance administrative user that was created at deployment. The root and admin accounts are not vulnerable. An attacker may be able to remotely access the BIG-IP host via SSH.
backupmgt/pre_connect_check.php in Seagate BlackArmor NAS contains a hard-coded password of '!~@##$$%FREDESWWSED' for a backdoor user.
iball Baton 150M iB-WRA150N v1 00000001 1.2.6 build 110401 Rel.47776n devices are prone to an authentication bypass vulnerability that allows remote attackers to view and modify administrative router settings by reading the HTML source code of the password.cgi file.
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.
The Data Warehouse component in NetApp OnCommand Insight before 7.2.3 allows remote attackers to obtain administrative access by leveraging a default privileged account.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a world-readable axess/opt/axXMPPHandler/config/xmpp_config.py file that stores hardcoded credentials.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the axiros password for the root account.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the cloud1234 password for the a1@chopin account default credentials.
D-Link D-View InstallApplication Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of D-Link D-View. Authentication is not required to exploit this vulnerability. The specific flaw exists within the InstallApplication class. The class contains a hard-coded password for the remotely reachable database. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-19553.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded adminpldt / z6dUABtl270qRxt7a2uGTiw credentials for an ISP.