iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices have a hardcoded password of admin for the admin account, a hardcoded password of support for the support account, and a hardcoded password of user for the user account.
ZModo ZP-NE14-S and ZP-IBH-13W devices have a hardcoded root password, which makes it easier for remote attackers to obtain access via a TELNET session.
Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Milesight IP security cameras through 2016-11-14 have a default root password in /etc/shadow that is the same across different customers' installations.
A low privileged admin account with a weak default password of admin exists on the Foxconn FEMTO AP-FC4064-T AP_GT_B38_5.8.3lb15-W47 LTE Build 15. In addition, its web management page relies on the existence or values of cookies when performing security-critical operations. One can gain privileges by modifying cookies.
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
A vulnerability was determined in yeqifu carRental up to 3fabb7eae93d209426638863980301d6f99866b3. Affected by this vulnerability is an unknown functionality of the file /carRental_war/druid/login.html of the component Druid. Executing manipulation can lead to hard-coded credentials. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. This product operates on a rolling release basis, ensuring continuous delivery. Consequently, there are no version details for either affected or updated releases.
Milesight IP security cameras through 2016-11-14 have a default set of 10 privileged accounts with hardcoded credentials. They are accessible if the customer has not configured 10 actual user accounts.
An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. There is a default password of meinsm for the admin account.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.
An issue was discovered in the MBeans Server in Wowza Streaming Engine before 4.7.1. The file system may be read and written to via JMX using the default JMX credentials (remote code execution may be possible as well).
The onelogin-saml-sso plugin before 2.2.0 for WordPress has a hardcoded @@@nopass@@@ password for just-in-time provisioned users.
A reliance on a static, hard-coded credential in the design of the cloud-based storage system of Practecol's Guardzilla All-In-One Video Security System allows an attacker to view the private data of all users of the Guardzilla device.
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
backupmgt/pre_connect_check.php in Seagate BlackArmor NAS contains a hard-coded password of '!~@##$$%FREDESWWSED' for a backdoor user.
The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI.
MASTER IPCAMERA01 3.3.4.2103 devices have a hardcoded password of cat1029 for the root account.
auth_db_config.py in Pyftpd 0.8.4 contains hard-coded usernames and passwords for the (1) test, (2) user, and (3) roxon accounts, which allows remote attackers to read arbitrary files from the FTP server.
Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password.
NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration.
The Fedora Nagios package uses "nagiosadmin" as the default password for the "nagiosadmin" administrator account, which makes it easier for remote attackers to obtain access by leveraging knowledge of the credentials.
An issue was discovered on the D-Link DWR-932B router. There is a hardcoded WPS PIN of 28296607.
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
Datto ALTO and SIRIS devices have a default VNC password.
In the web server on D-Link DIR-620 devices with a certain customized (by ISP) variant of firmware 1.0.3, 1.0.37, 1.3.1, 1.3.3, 1.3.7, 1.4.0, and 2.0.22, there is a hardcoded password of anonymous for the admin account.
ZTE E8810/E8820/E8822 series routers have an information leak vulnerability, which is caused by hard-coded MQTT service access credentials on the device. The remote attacker could use this credential to connect to the MQTT server, so as to obtain information about other devices by sending specific topics. This affects:<ZXHN E8810, ZXHN E8820, ZXHN E8822><E8810 V1.0.26, E8810 V2.0.1, E8820 V1.1.3L, E8820 V2.0.13, E8822 V2.0.13>
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The exported device configuration is encrypted with the hardcoded Pxift* password in some cases.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
IBM Security Identity Governance and Intelligence 5.2 through 5.2.4.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153386.
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials.
A vulnerability in the Telnet service of Cisco Small Business RV110W Wireless-N VPN Firewall Routers could allow an unauthenticated, remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password. An attacker could exploit this vulnerability by using this default account to connect to the affected system. A successful exploit could allow the attacker to gain full control of an affected device.
A hidden backdoor on PATLITE NH-FB Series devices with firmware version 1.45 or earlier, NH-FV Series devices with firmware version 1.10 or earlier, and NBM Series devices with firmware version 1.09 or earlier allow attackers to enable an SSH daemon via the "kankichi" or "kamiyo4" password to the _secret1.htm URI. Subsequently, the default password of root for the root account allows an attacker to conduct remote code execution and as a result take over the system.
NUUO CMS all versions 3.1 and prior, The application creates default accounts that have hard-coded passwords, which could allow an attacker to gain privileged access.
Hardcoded credentials in the Ricoh myPrint application 2.9.2.4 for Windows and 2.2.7 for Android give access to any externally disclosed myPrint WSDL API, as demonstrated by discovering API secrets of related Google cloud printers, encrypted passwords of mail servers, and names of printed files.
Deltek Vision 7.x before 7.6 permits the execution of any attacker supplied SQL statement through a custom RPC over HTTP protocol. The Vision system relies on the client binary to enforce security rules and integrity of SQL statements and other content being sent to the server. Client HTTP calls can be manipulated by one of several means to execute arbitrary SQL statements (similar to SQLi) or possibly have unspecified other impact via this custom protocol. To perform these attacks an authenticated session is first required. In some cases client calls are obfuscated by encryption, which can be bypassed due to hard-coded keys and an insecure key rotation protocol. Impacts may include remote code execution in some deployments; however, the vendor states that this cannot occur when the installation documentation is heeded.
Allegra Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Allegra. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of a database. The issue results from the use of a hardcoded password. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-22360.
Lens Peek-a-View has a password of 2601hx for the backdoor admin account, a password of user for the backdoor user account, and a password of guest for the backdoor guest account.
spaces.htm on multiple D-Link devices (DSL, DIR, DWR) allows remote unauthenticated attackers to discover admin credentials.
Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.
Swann SWWHD-INTCAM-HD devices have the twipc root password, leading to FTP access as root. NOTE: all affected customers were migrated by 2020-08-31.