A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) V4.0 (All versions), SIMATIC PCS neo (Administration Console) V4.0 Update 1 (All versions). The affected application leaks Windows admin credentials. An attacker with local access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications accept unauthenticated file write messages. An unauthenticated remote attacker could write arbitrary files to the affected application's file system.
The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).
A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data.
curl 7.61.0 through 7.76.1 suffers from exposure of data element to wrong session due to a mistake in the code for CURLOPT_SSL_CIPHER_LIST when libcurl is built to use the Schannel TLS library. The selected cipher set was stored in a single "static" variable in the library, which has the surprising side-effect that if an application sets up multiple concurrent transfers, the last one that sets the ciphers will accidentally control the set used by all transfers. In a worst-case scenario, this weakens transport security significantly.
A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The service log files of the affected application can be accessed without proper authentication. This could allow an unauthenticated attacker to get access to sensitive information.
While investigating bug 60718, it was noticed that some calls to application listeners in Apache Tomcat 9.0.0.M1 to 9.0.0.M17, 8.5.0 to 8.5.11, 8.0.0.RC1 to 8.0.41, and 7.0.0 to 7.0.75 did not use the appropriate facade object. When running an untrusted application under a SecurityManager, it was therefore possible for that untrusted application to retain a reference to the request or response object and thereby access and/or modify information associated with another web application.
In a openshift node, there is a cron job to update mcollective facts that mishandles a temporary file. This may lead to loss of confidentiality and integrity.
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by incorrect access control. Lack of access control on the web manger pages allows any user to view and modify information.
IBM Security Guardium Big Data Intelligence (SonarG) 4.0 specifies permissions for a security-critical resource which could lead to the exposure of sensitive information or the modification of that resource by unintended parties. IBM X-Force ID: 160986.
In Apache Ozone versions prior to 1.2.0, Container related Datanode requests of Ozone Datanode were not properly authorized and can be called by any client.
python-docutils allows insecure usage of temporary files
Nextcloud server is an open source, self hosted personal cloud. In affected versions an attacker is able to bypass Two Factor Authentication in Nextcloud. Thus knowledge of a password, or access to a WebAuthN trusted device of a user was sufficient to gain access to an account. It is recommended that the Nextcloud Server is upgraded to 20.0.12, 21.0.4 or 22.1.0. There are no workaround for this vulnerability.
SonLogger before 6.4.1 is affected by user creation with any user permissions profile (e.g., SuperAdmin). An anonymous user can send a POST request to /User/saveUser without any authentication or session header.
IBM SmartCloud Analytics 1.3.1 through 1.3.5 could allow a remote attacker to gain unauthorized information and unrestricted control over Zookeeper installations due to missing authentication. IBM X-Force ID: 159518.
An issue discovered on D-Link DIR-615 devices with firmware version 20.05 and 20.07. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
There are some web interfaces without authentication requirements on D-Link DIR-412 A1-1.14WW routers. An attacker can clear the router's log file via act=clear&logtype=sysact to log_clear.php, which could be used to erase attack traces.
Mondo 2.24 has insecure handling of temporary files.
Xvfb of SAP Business Objects Business Intelligence Platform, versions - 4.2, 4.3, platform on Unix does not perform any authentication checks for functionalities that require user identity.
A vulnerability in the REST API endpoint of Cisco Vision Dynamic Signage Director could allow an unauthenticated, remote attacker to bypass authentication on an affected device. The vulnerability is due to missing authentication on some of the API calls. An attacker could exploit this vulnerability by sending a request to one of the affected calls. A successful exploit could allow the attacker to interact with some parts of the API.
An issue was discovered in LibreNMS through 1.47. A number of scripts import the Authentication libraries, but do not enforce an actual authentication check. Several of these scripts disclose information or expose functions that are of a sensitive nature and are not expected to be publicly accessible.
An issue was discovered in servletcontroller in the secure portal in Publisure 2.1.2. One can bypass authentication and perform a query on PHP forms within the /AdminDir folder that should be restricted.
An issue was discovered in SquareBox CatDV Server through 9.2. An attacker can invoke sensitive RMI methods such as getConnections without authentication, the results of which can be used to generate valid authentication tokens. These tokens can then be used to invoke administrative tasks within the application, such as disclosing password hashes.
A vulnerability in the web-based management interface of Cisco Vision Dynamic Signage Director could allow an unauthenticated, remote attacker to access confidential information or make configuration changes. The vulnerability is due to missing authentication for a specific section of the web-based management interface. An attacker could exploit this vulnerability by accessing a crafted URL. A successful exploit could allow the attacker to obtain access to a section of the interface, which they could use to read confidential information or make configuration changes.
Installations, where crafter-search is not protected, allow unauthenticated remote attackers to create, view, and delete search indexes.
The Web CGI Script on ZyXEL LTE4506-M606 V1.00(ABDO.2)C0 devices does not require authentication, which allows remote unauthenticated attackers (via crafted JSON action data to /cgi-bin/gui.cgi) to use all features provided by the router. Examples: change the router password, retrieve the Wi-Fi passphrase, send an SMS message, or modify the IP forwarding to access the internal network.
In versions of Couchbase Server prior to 5.0, the bucket named "default" was a special bucket that allowed read and write access without authentication. As part of 5.0, the behavior of all buckets including "default" were changed to only allow access by authenticated users with sufficient authorization. However, users were allowed unauthenticated and unauthorized access to the "default" bucket if the properties of this bucket were edited. This has been fixed in versions 5.1.0 and 5.5.0.
The Electron framework lets users write cross-platform desktop applications using JavaScript, HTML and CSS. In versions of Electron IPC prior to 9.4.0, 10.2.0, 11.1.0, and 12.0.0-beta.9, messages sent from the main process to a subframe in the renderer process, through webContents.sendToFrame, event.reply or when using the remote module, can in some cases be delivered to the wrong frame. If your app uses remote, calls webContents.sendToFrame, or calls event.reply in an IPC message handler then it is impacted by this issue. This has been fixed in versions 9.4.0, 10.2.0, 11.1.0, and 12.0.0-beta.9. There are no known workarounds for this issue.
Envoy is a cloud-native high-performance proxy. In versions prior to 1.22.1 the OAuth filter implementation does not include a mechanism for validating access tokens, so by design when the HMAC signed cookie is missing a full authentication flow should be triggered. However, the current implementation assumes that access tokens are always validated thus allowing access in the presence of any access token attached to the request. Users are advised to upgrade. There is no known workaround for this issue.
The default configuration of Crimson 3.1 (Build versions prior to 3119.001) allows a user to be able to read and modify the database without authentication.
User can access /plugin api without authentication. This issue affected Apache ShenYu 2.4.0 and 2.4.1.
Winston 1.5.4 devices have a CORS configuration that trusts arbitrary origins. This allows requests to be made and viewed by arbitrary origins.
Missing Authentication for Critical Function in temi Robox OS prior to 120, temi Android app up to 1.3.7931 allows remote attackers to receive and answer calls intended for another temi user. Answering the call this way grants motor control of the temi in addition to audio/video via unspecified vectors.
It was found that the REST API in Infinispan before version 9.0.0 did not properly enforce auth constraints. An attacker could use this vulnerability to read or modify data in the default cache or a known cache name.
openSIS through 7.4 has Incorrect Access Control.
LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data.
An issue was discovered in the WPGraphQL 0.2.3 plugin for WordPress. By querying the 'users' RootQuery, it is possible, for an unauthenticated attacker, to retrieve all WordPress users details such as email address, role, and username.
A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data.
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166).
PrinterLogic Web Stack versions 19.1.1.13 SP9 and below are vulnerable to an Insecure Direct Object Reference (IDOR) vulnerability that allows an unauthenticated attacker to reassign drivers for any printer.
Tad Book3 editing book page does not perform identity verification. Remote attackers can use the vulnerability to view and modify arbitrary content of books without permission.
Tad Web is vulnerable to authorization bypass, thus remote attackers can exploit the vulnerability to use the original function of viewing bulletin boards and uploading files in the system.
A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected.
IBM Guardium Data Encryption (GDE) 3.0.0.2 and 4.0.0.4 does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
Multiple vulnerabilities in Cisco Application Services Engine could allow an unauthenticated, remote attacker to gain privileged access to host-level operations or to learn device-specific information, create diagnostic files, and make limited configuration changes. For more information about these vulnerabilities, see the Details section of this advisory.
On versions 15.1.0-15.1.0.1, 15.0.0-15.0.1.2, and 14.1.0-14.1.2.3, BIG-IP Virtual Edition (VE) may expose a mechanism for remote attackers to access local daemons and bypass port lockdown settings.
IBM Planning Analytics Local 2.0 connects to a Redis server. The Redis server, an in-memory data structure store, running on the remote host is not protected by password authentication. A remote attacker can exploit this to gain unauthorized access to the server. IBM X-Force ID: 186401.
In BIG-IQ 6.0.0-6.1.0, services for stats do not require authentication nor do they implement any form of Transport Layer Security (TLS).