An issue was discovered in AUO Solar Data Recorder before 1.3.0. The web portal uses HTTP Basic Authentication and provides the account and password in the WWW-Authenticate attribute. By using this account and password, anyone can login successfully.
Improper Access Control in the RCP+ server of the Bosch Video Recording Manager (VRM) component allows arbitrary and unauthenticated access to a limited subset of certificates, stored in the underlying Microsoft Windows operating system. The fixed versions implement modified authentication checks. Prior releases of VRM software version 3.70 are considered unaffected. This vulnerability affects VRM v3.70.x, v3.71 < v3.71.0034 and v3.81 < 3.81.0050; DIVAR IP 5000 3.80 < 3.80.0039; BVMS all versions using VRM.
AOMEI Cyber Backup Missing Authentication for Critical Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of AOMEI Cyber Backup. Authentication is not required to exploit this vulnerability. The specific flaw exists within the DaoService service, which listens on TCP port 9074 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-26158.
The SSH Plugin stores credentials which allow jobs to access remote servers via the SSH protocol. User passwords and passphrases for encrypted SSH keys are stored in plaintext in a configuration file.
CloudBees Jenkins Operations Center 2.150.2.3, when an expired trial license exists, allows Cleartext Password Storage and Retrieval via the proxy configuration page.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/setSysAdm to edit the web or system account without authentication.
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/form2userconfig.cgi to edit the system account without authentication.
TeamPass version 2.1.27 and earlier contains a Storing Passwords in a Recoverable Format vulnerability in Shared password vaults that can result in all shared passwords are recoverable server side. This attack appears to be exploitable via any vulnerability that can bypass authentication or role assignment and can lead to shared password leakage.
Aquaverde GmbH Aquarius CMS prior to version 4.1.1 is affected by: Incorrect Access Control. The impact is: The access to the log file is not restricted. It contains sensitive information like passwords etc. The component is: log file. The attack vector is: open the file.
A security regression of CVE-2019-9636 was discovered in python since commit d537ab0ff9767ef024f26246899728f0116b1ec3 affecting versions 2.7, 3.5, 3.6, 3.7 and from v3.8.0a4 through v3.8.0b1, which still allows an attacker to exploit CVE-2019-9636 by abusing the user and password parts of a URL. When an application parses user-supplied URLs to store cookies, authentication credentials, or other kind of information, it is possible for an attacker to provide specially crafted URLs to make the application locate host-related information (e.g. cookies, authentication data) and send them to a different host than where it should, unlike if the URLs had been correctly parsed. The result of an attack may vary based on the application.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use a hidden API URL /goform/SystemCommand to execute a system command without authentication.
Under certain circumstances, SAP HANA Extended Application Services, advanced model (XS advanced) does not perform authentication checks properly for XS advanced platform and business users. Fixed in 1.0.97 to 1.0.99 (running on SAP HANA 1 or SAP HANA 2 SPS0 (second S stands for stack)).
A cleartext password storage issue was discovered on MicroDigital N-series cameras with firmware through 6400.0.8.5. The file in question is /usr/local/ipsca/mipsca.db. If a camera is compromised, the attacker can gain access to passwords and abuse them to compromise further systems.
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
A broken access control vulnerability in Smart Battery A4, a multifunctional portable charger, firmware version ?<= r1.7.9 allows an attacker to get/reset administrator’s password without any authentication.
Contec Smart Home 4.15 devices do not require authentication for new_user.php, edit_user.php, delete_user.php, and user.php, as demonstrated by changing the admin password and then obtaining control over doors.
SAP Business Objects Business Intelligence Platform (Live Data Connect), versions 1.0, 2.0, 2.1, 2.2, 2.3, allows an attacker to logon on the Central Management Console without password in case of the BIPRWS application server was not protected with some specific certificate, leading to Missing Authentication Check.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
If an attacker has access to the firmware from the VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) they may be able to extract credentials.
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface.
The login interface on TNLSoftSolutions Sentry Vision 3.x devices provides password disclosure by reading an "if(pwd ==" line in the HTML source code. This means, in effect, that authentication occurs only on the client side.
The default configuration in Apache Cassandra 3.8 through 3.11.1 binds an unauthenticated JMX/RMI interface to all network interfaces, which allows remote attackers to execute arbitrary Java code via an RMI request. This issue is a regression of CVE-2015-0225. The regression was introduced in https://issues.apache.org/jira/browse/CASSANDRA-12109. The fix for the regression is implemented in https://issues.apache.org/jira/browse/CASSANDRA-14173. This fix is contained in the 3.11.2 release of Apache Cassandra.
In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.
In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication.
The TP-LINK EAP Controller is TP-LINK's software for remotely controlling wireless access point devices. It utilizes a Java remote method invocation (RMI) service for remote control. The RMI interface does not require any authentication before use, so it lacks user authentication for RMI service commands in EAP controller versions 2.5.3 and earlier. Remote attackers can implement deserialization attacks through the RMI protocol. Successful attacks may allow a remote attacker to remotely control the target server and execute Java functions or bytecode.
Dynacolor FCM-MB40 v1.2.0.0 use /etc/appWeb/appweb.pass to store administrative web-interface credentials in cleartext. These credentials can be retrieved via cgi-bin/getuserinfo.cgi?mode=info.
SAP Cloud Connector, before version 2.11.3, does not perform any authentication checks for functionalities that require user identity.
In NICE Engage through 6.5, the default configuration binds an unauthenticated JMX/RMI interface to all network interfaces, without restricting registration of MBeans, which allows remote attackers to execute arbitrary code via the RMI protocol by using the JMX connector. The observed affected TCP port is 6338 but, based on the product's configuration, a different one could be vulnerable.
CastleNet CBV38Z4EC 125.553mp1.39219mp1.899.007, CBV38Z4ECNIT 125.553mp1.39219mp1.899.005ITT, CBW383G4J 37.556mp5.008, and CBW38G4J 37.553mp1.008 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
NETWAVE MNG6200 C4835805jrc12FU121413.cpr devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Zoom 5352 v5.5.8.6Y devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Technicolor DPC3928SL D3928SL-PSIP-13-A010-c3420r55105-170214a devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.4413.2.2.2.1.5.4.1.14.1.3.10001 and 1.3.6.1.4.1.4413.2.2.2.1.18.1.2.3.4.1.2.10001 SNMP requests.
Technicolor TC7110.B STC8.62.02 devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.2863.205.10.1.30.4.1.14.1.3.32 and iso.3.6.1.4.1.2863.205.10.1.30.4.2.4.1.2.32 SNMP requests.
Insecure Cryptographic Storage of credentials in com.vestiacom.qbeecamera_preferences.xml in the QBee Cam application through 1.0.5 for Android allows an attacker to retrieve the username and password.
Technicolor TC7200.TH2v2 SC05.00.22 devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.2863.205.10.1.30.4.1.14.1.3.32 and iso.3.6.1.4.1.2863.205.10.1.30.4.2.4.1.2.32 SNMP requests.
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
Thomson DWG849 STC0.01.16, DWG850-4 ST9C.05.25, DWG855 ST80.20.26, and TWG870 STB2.01.36 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Bnmux BCW700J 5.20.7, BCW710J 5.30.6a, and BCW710J2 5.30.16 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Skyworth CM5100 V1.1.0, CM5100-440 V1.2.1, CM5100-511 4.1.0.14, CM5100-GHD00 V1.2.2, and CM5100.g2 4.1.0.17 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Technicolor CWA0101 CWA0101E-A23E-c7000r5712-170315-SKC devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.4413.2.2.2.1.5.4.1.14.1.3.10001 and 1.3.6.1.4.1.4413.2.2.2.1.18.1.2.3.4.1.2.10001 SNMP requests.
Motorola SBG901 SBG901-2.10.1.1-GA-00-581-NOSH, SBG941 SBG941-2.11.0.0-GA-07-624-NOSH, and SVG1202 SVG1202-2.1.0.0-GA-14-LTSH devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Jiuzhou BCM93383WRG 139.4410mp1.3921132mp1.899.004404.004 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Technicolor TC7110.AR STD3.38.03 devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.2863.205.10.1.30.4.1.14.1.3.32 and iso.3.6.1.4.1.2863.205.10.1.30.4.2.4.1.2.32 SNMP requests.
Technicolor CGA0111 CGA0111E-ES-13-E23E-c8000r5712-170217-0829-TRU devices allow remote attackers to discover Wi-Fi credentials via iso.3.6.1.4.1.4413.2.2.2.1.5.4.1.14.1.3.10001 and 1.3.6.1.4.1.4413.2.2.2.1.18.1.2.3.4.1.2.10001 SNMP requests.
S-A WebSTAR DPC2100 v2.0.2r1256-060303 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
mplus CBC383Z CBC383Z_mplus_MDr026 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.
Ubee DVW2108 6.28.1017 and DVW2110 6.28.2012 devices allow remote attackers to discover credentials via iso.3.6.1.4.1.4491.2.4.1.1.6.1.1.0 and iso.3.6.1.4.1.4491.2.4.1.1.6.1.2.0 SNMP requests.