This issue is not applicable to NFX NextGen Software. On NFX Series devices the use of Hard-coded Credentials in Juniper Networks Junos OS allows an attacker to take over any instance of an NFX deployment. This issue is only exploitable through administrative interfaces. This issue affects: Juniper Networks Junos OS versions prior to 19.1R1 on NFX Series. No other platforms besides NFX Series devices are affected.
Deltek Vision 7.x before 7.6 permits the execution of any attacker supplied SQL statement through a custom RPC over HTTP protocol. The Vision system relies on the client binary to enforce security rules and integrity of SQL statements and other content being sent to the server. Client HTTP calls can be manipulated by one of several means to execute arbitrary SQL statements (similar to SQLi) or possibly have unspecified other impact via this custom protocol. To perform these attacks an authenticated session is first required. In some cases client calls are obfuscated by encryption, which can be bypassed due to hard-coded keys and an insecure key rotation protocol. Impacts may include remote code execution in some deployments; however, the vendor states that this cannot occur when the installation documentation is heeded.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results.
ZyXEL ZyWALL 1050 has a hard-coded password for the Quagga and Zebra processes that is not changed when it is set by a user, which allows remote attackers to gain privileges.
IBM Security Verify Access 10.7 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 181395.
IBM Spectrum Protect Plus 10.1.0 thorugh 10.1.6 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 190454.
IBM Security Guardium 11.3 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 186697.
IBM Spectrum Protect Plus 10.1.0 through 10.1.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174975.
IBM Security Guardium 11.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174732.
IBM SiteProtector Appliance 3.1.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174142.
IBM Spectrum Protect Plus 10.1.0 through 10.1.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 175066.
The Web Administrative Interface in Mobile Viewpoint Wireless Multiplex Terminal (WMT) Playout Server 20.2.8 and earlier has a default account with a password of "pokon."
Dairy Farm Shop Management System v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised.
A vulnerability in Cisco Virtual Wide Area Application Services (vWAAS) with Cisco Enterprise NFV Infrastructure Software (NFVIS)-bundled images for Cisco ENCS 5400-W Series and CSP 5000-W Series appliances could allow an unauthenticated, remote attacker to log into the NFVIS CLI of an affected device by using accounts that have a default, static password. The vulnerability exists because the affected software has user accounts with default, static passwords. An attacker with access to the NFVIS CLI of an affected device could exploit this vulnerability by logging into the CLI. A successful exploit could allow the attacker to access the NFVIS CLI with administrator privileges.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default debug124 password for the debug account.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default root126 password for the root account.
Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default blank password for the guest account.
Use of Hard-coded Credentials in /var/www/xms/application/controllers/gatherLogs.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to interact with a web service.
Barco wePresent WiPG-1600W firmware includes a hardcoded API account and password that is discoverable by inspecting the firmware image. A malicious actor could use this password to access authenticated, administrative functions in the API. Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19.
ASUSTOR ADM 3.1.0.RFQ3 uses the same default root:admin username and password as it does for the NAS itself for applications that are installed from the online repository. This may allow an attacker to login and upload a webshell.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default panger123 password for the suma123 account for certain old firmware.
In SapphireIMS 5.0, it is possible to use the hardcoded credential in clients (username: sapphire, password: ims) and gain access to the portal. Once the access is available, the attacker can inject malicious OS commands on “ping”, “traceroute” and “snmp” functions and execute code on the server. We also observed the same is true if the JSESSIONID is completely removed.
Use of a Hard-coded Cryptographic Key used to protect cookie session data in /var/www/xms/application/config/config.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to bypass authentication.
The JWT library in NATS nats-server before 2.1.9 has Incorrect Access Control because of how expired credentials are handled.
Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100 utilizes hard-coded credentials that may allow an attacker to reset passwords for the controller.
Directus 6.4.9 has a hardcoded admin password for the Admin account because of an INSERT statement in api/schema.sql.
In Dedos-web 1.0, the cookie and session secrets used in the Express.js application have hardcoded values that are visible in the source code published on GitHub. An attacker can edit the contents of the session cookie and re-sign it using the hardcoded secret. Due to the use of Passport.js, this could lead to privilege escalation.
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Hardcoded credentials exist for an unprivileged SSH account with a shell of /bin/false.
In SapphireIMS 5.0, it is possible to use the hardcoded credential in clients (username: sapphire, password: ims) and gain access to the portal. Once the access is available, the attacker can inject malicious OS commands on “ping”, “traceroute” and “snmp” functions and execute code on the server.
Juniper Networks Contrail Service Orchestration releases prior to 4.0.0 have Grafana service enabled by default with hardcoded credentials. These credentials allow network based attackers unauthorized access to information stored in Grafana or exploit other weaknesses or vulnerabilities in Grafana.
An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass
Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 have Cassandra service enabled by default with hardcoded credentials. These credentials allow network based attackers unauthorized access to information stored in Cassandra.
Juniper Networks Contrail Service Orchestration releases prior to 3.3.0 use hardcoded credentials to access Keystone service. These credentials allow network based attackers unauthorized access to information stored in keystone.
Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account.
Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices have default credentials that are hardcoded in the firmware and can be extracted by anyone who reverses the firmware to identify them. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable function that sets up the default credentials on the device. If one opens this binary in IDA-pro, one will notice that this follows a ARM little endian format. The function sub_3DB2FC in IDA pro is identified to be setting up the values at address 0x003DB5A6. The sub_5C057C then sets this value and adds it to the Configuration files in /mnt/mtd/Config/Account1 file.
Inim Electronics Smartliving SmartLAN/G/SI <=6.x uses default hardcoded credentials. An attacker could exploit this to gain Telnet, SSH and FTP access to the system.
Multiple hardcoded credentials in Xsuite 2.x.
The server API in the Anda app relies on hardcoded credentials.
Intellinet NFC-30ir IP Camera has a vendor backdoor that can allow a remote attacker access to a vendor-supplied CGI script in the web directory.
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
A hard-coded cryptographic key vulnerability in the default configuration file was found in Kiali, all versions prior to 1.15.1. A remote attacker could abuse this flaw by creating their own JWT signed tokens and bypass Kiali authentication mechanisms, possibly gaining privileges to view and alter the Istio configuration.
/usr/lib/lua/luci/websys.lua on TP-LINK IPC TL-IPC223(P)-6, TL-IPC323K-D, TL-IPC325(KP)-*, and TL-IPC40A-4 devices has a hardcoded zMiVw8Kw0oxKXL0 password.
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They contain two undocumented administrator accounts. The sftp and mofidev accounts are defined in /etc/passwd and the password is not unique across installations.
Denbun by NEOJAPAN Inc. (Denbun POP version V3.3P R4.0 and earlier, Denbun IMAP version V3.3I R4.0 and earlier) uses hard-coded credentials, which may allow remote attackers to login to the Management page and change the configuration.
The Web Panel in Netsweeper before 4.0.5 has a default password of branding for the branding account, which makes it easier for remote attackers to obtain access via a request to webadmin/.
Denbun by NEOJAPAN Inc. (Denbun POP version V3.3P R4.0 and earlier, Denbun IMAP version V3.3I R4.0 and earlier) uses hard-coded credentials, which may allow remote attackers to read/send mail or change the configuration.
A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials.
The National Payments Corporation of India BHIM application 1.3 for Android relies on three hardcoded strings (AK-NPCIMB, IM-NPCIBM, and VK-NPCIBM) for SMS validation, which makes it easier for attackers to bypass authentication.
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.