IBM Security Guardium 11.2 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 196279.
IBM BigFix Compliance (TEMA SUAv1 SCA SCM) 1.9.70 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 123671.
Hikvision DVR DS-7204HGHI-F1 V4.0.1 build 180903 Web Version sends a different response for failed ISAPI/Security/sessionLogin/capabilities login attempts depending on whether the user account exists, which might make it easier to enumerate users. However, only about 4 or 5 failed logins are allowed.
Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a password when brute force is used.
A vulnerability was found in Thecosy IceCMS 2.0.1. It has been classified as problematic. Affected is an unknown function of the file /login of the component Captcha Handler. The manipulation leads to improper restriction of excessive authentication attempts. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-247884.
An issue was discovered in GitLab Community and Enterprise Edition 11.3 to 12.3 in the protected environments feature. It has Insecure Permissions (issue 3 of 4).
An issue was discovered in GitLab Community and Enterprise Edition 11.3 through 12.4 when moving an issue to a public project from a private one. It has Insecure Permissions.
Pimcore before 6.2.2 lacks brute force protection for the 2FA token.
An issue was discovered in GitLab Community and Enterprise Edition 8.17 through 12.4 in the Search feature provided by Elasticsearch integration.. It has Insecure Permissions (issue 1 of 4).
In Omron PLC CS series, all versions, Omron PLC CJ series, all versions, and Omron PLC NJ series, all versions, the software does not implement sufficient measures to prevent multiple failed authentication attempts within in a short time frame, making it more susceptible to brute force attacks.
Limesurvey before 3.17.14 uses an anti-CSRF cookie without the HttpOnly flag, which allows attackers to access a cookie value via a client-side script.
phpMyFAQ before 2.9.8 does not properly mitigate brute-force attacks that try many passwords in attempted logins quickly.
SilverStripe through 4.3.3 has incorrect access control for protected files uploaded via Upload::loadIntoFile(). An attacker may be able to guess a filename in silverstripe/assets via the AssetControlExtension.
In Perun before version 3.9.1, VO or group manager can modify configuration of the LDAP extSource to retrieve all from Perun LDAP. Issue is fixed in version 3.9.1 by sanitisation of the input.
BigAnt Server v5.6.06 was discovered to contain an incorrect access control issue.
A security feature bypass vulnerability exists in Active Directory Federation Services (ADFS) which could allow an attacker to bypass the extranet lockout policy.To exploit this vulnerability, an attacker could run a specially crafted application, which would allow an attacker to launch a password brute-force attack or cause account lockouts in Active Directory.This security update corrects how ADFS handles external authentication requests., aka 'ADFS Security Feature Bypass Vulnerability'. This CVE ID is unique from CVE-2019-0975.
The Telenav Scout GPS Link app 1.x for iOS, as used with Toyota and Lexus vehicles, has an incorrect protection mechanism against brute-force attacks on the authentication process, which makes it easier for attackers to obtain multimedia-screen access via port 7050 on the cellular network, as demonstrated by a DrivingRestriction method call to uma/jsonrpc/mobile.
OpenStack Keystone 10.x through 16.x before 16.0.2, 17.x before 17.0.1, 18.x before 18.0.1, and 19.x before 19.0.1 allows information disclosure during account locking (related to PCI DSS features). By guessing the name of an account and failing to authenticate multiple times, any unauthenticated actor could both confirm the account exists and obtain that account's corresponding UUID, which might be leveraged for other unrelated attacks. All deployments enabling security_compliance.lockout_failure_attempts are affected.
InHand Networks IR615 Router's Versions 2.3.0.r4724 and 2.3.0.r4870 have has no account lockout policy configured for the login page of the product. This may allow an attacker to execute a brute-force password attack with no time limitation and without harming the normal operation of the user. This could allow an attacker to gain valid credentials for the product interface.
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.
IBM Security Identity Governance and Intelligence 5.2.6 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 175423.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) did not implement account lockout. Local account credentials may be extracted from the device via brute force guessing attacks.
IBM Verify Gateway (IVG) 1.0.0 and 1.0.1 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 179478.
IBM Tivoli Key Lifecycle Manager 3.0.1 and 4.0 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 184156.
An issue was discovered in shadow 4.5. newgidmap (in shadow-utils) is setuid and allows an unprivileged user to be placed in a user namespace where setgroups(2) is permitted. This allows an attacker to remove themselves from a supplementary group, which may allow access to certain filesystem paths if the administrator has used "group blacklisting" (e.g., chmod g-rwx) to restrict access to paths. This flaw effectively reverts a security feature in the kernel (in particular, the /proc/self/setgroups knob) to prevent this sort of privilege escalation.
Nextcloud Server is a Nextcloud package that handles data storage. In versions prior to 19.0.13, 20.011, and 21.0.3, there was a lack of ratelimiting on the shareinfo endpoint. This may have allowed an attacker to enumerate potentially valid share tokens. The issue was fixed in versions 19.0.13, 20.0.11, and 21.0.3. There are no known workarounds.
Ricoh SP C250DN 1.05 devices have an Authentication Method Vulnerable to Brute Force Attacks. Some Ricoh printers did not implement account lockout. Therefore, it was possible to obtain the local account credentials by brute force.
IBM Security Information Queue (ISIQ) 1.0.0, 1.0.1, 1.0.2, 1.0.3, 1.0.4, and 1.0.5 could allow a remote attacker to obtain sensitive information, caused by the failure to set the HTTPOnly flag. A remote attacker could exploit this vulnerability to obtain sensitive information from the cookie. IBM X-Force ID: 176332.
IBM Security Identity Governance and Intelligence 5.2.6 could allow an attacker to enumerate usernames to find valid login credentials which could be used to attempt further attacks against the system. IBM X-Force ID: 175336.
Open Dental before version 18.4 installs a mysql database and uses the default credentials of "root" with a blank password. This allows anyone on the network with access to the server to access all database information.
IBM Security SiteProtector System 3.1.1 could allow a remote attacker to obtain sensitive information, caused by missing 'HttpOnly' flag. A remote attacker could exploit this vulnerability to obtain sensitive information. IBM X-Force ID: 174129.
If REST API is enabled, the Junos OS login credentials are vulnerable to brute force attacks. The high default connection limit of the REST API may allow an attacker to brute-force passwords using advanced scripting techniques. Additionally, administrators who do not enforce a strong password policy can increase the likelihood of success from brute force attacks. Affected releases are Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D49; 15.1 versions prior to 15.1F6-S12, 15.1R7-S3; 15.1X49 versions prior to 15.1X49-D160; 15.1X53 versions prior to 15.1X53-D236, 15.1X53-D495, 15.1X53-D591, 15.1X53-D69; 16.1 versions prior to 16.1R3-S10, 16.1R4-S12, 16.1R6-S6, 16.1R7-S3; 16.1X65 versions prior to 16.1X65-D49; 16.2 versions prior to 16.2R2-S7; 17.1 versions prior to 17.1R2-S10, 17.1R3; 17.2 versions prior to 17.2R1-S8, 17.2R3-S1; 17.3 versions prior to 17.3R3-S2; 17.4 versions prior to 17.4R1-S6, 17.4R2-S2; 18.1 versions prior to 18.1R2-S4, 18.1R3-S1; 18.2 versions prior to 18.2R1-S5; 18.2X75 versions prior to 18.2X75-D30; 18.3 versions prior to 18.3R1-S1.
An insecure permissions issue was discovered in GitLab Community and Enterprise Edition 9.4 and later but before 11.4.13, 11.5.x before 11.5.6, and 11.6.x before 11.6.1. The runner registration token in the CI/CD settings could not be reset. This was a security risk if one of the maintainers leaves the group and they know the token.
An issue was discovered in Stormshield SNS through 4.2.1. A brute-force attack can occur.
index.php?r=site%2Flogin in EduSec through 4.2.6 does not restrict sending a series of LoginForm[username] and LoginForm[password] parameters, which might make it easier for remote attackers to obtain access via a brute-force approach.
An issue was discovered in /cgi-bin/luci on Teltonika RTU9XX (e.g., RUT950) R_31.04.89 before R_00.05.00.5 devices. The authentication functionality is not protected from automated tools used to make login attempts to the application. An anonymous attacker has the ability to make unlimited login attempts with an automated tool. This ability could lead to cracking a targeted user's password.
A JSON Injection vulnerability exists in the `mintplex-labs/anything-llm` application, specifically within the username parameter during the login process at the `/api/request-token` endpoint. The vulnerability arises from improper handling of values, allowing attackers to perform brute force attacks without prior knowledge of the username. Once the password is known, attackers can conduct blind attacks to ascertain the full username, significantly compromising system security.
IBM Security Identity Manager 6.0.0 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 153628.
Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.
IBM Security Guardium 11.2 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 196314.
IBM Security Privileged Identity Manager Virtual Appliance 2.2.1 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 145236.
Insecure permissions in Lone Wolf Technologies loadingDOCS 2018-08-13 allow remote attackers to download any confidential files via https requests for predictable URLs.
An issue was discovered in BTITeam XBTIT 2.5.4. When a user logs in, their password hash is rehashed using a predictable salt and stored in the "pass" cookie, which is not flagged as HTTPOnly. Due to the weak and predictable salt that is in place, an attacker who successfully steals this cookie can efficiently brute-force it to retrieve the user's cleartext password.
A vulnerability in the application policy configuration of Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to gain unauthorized read access to sensitive data on an affected device. The vulnerability is due to insufficient application identification. An attacker could exploit this vulnerability by sending crafted traffic to an affected device. A successful exploit could allow the attacker to gain unauthorized read access to sensitive data.
IBM BigFix Platform 9.2 and 9.5 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 140756.
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to gain full access by brute force.
Incorrect access control in the /mysql/api/droboapp/data endpoint in Drobo 5N2 NAS version 4.0.5-13.28.96115 allows unauthenticated attackers to retrieve the MySQL database root password.
IBM Tivoli Key Lifecycle Manager does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 184181.
IBM Cloud Pak for Security 1.3.0.1(CP4S) could allow a remote attacker to obtain sensitive information, caused by the failure to set the HTTPOnly flag. A remote attacker could exploit this vulnerability to obtain sensitive information from the cookie.
HCL AppScan Standard is vulnerable to excessive authorization attempts