PTC ThingWorx Platform through 8.3.0 is vulnerable to a directory traversal attack on ZIP files via a POST request.
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) supplies the event log of the specific service.
When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) (disregarding Axeda agent v6.9.2 and v6.9.3) is vulnerable to directory traversal, which could allow a remote unauthenticated attacker to obtain file system read access via web server..
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.
Western Digital SSD Dashboard before 2.5.1.0 and SanDisk SSD Dashboard before 2.5.1.0 have Incorrect Access Control. The “generate reports” archive is protected with a hard-coded password. An application update that addresses the protection of archive encryption is available.
iball Baton 150M iB-WRA150N v1 00000001 1.2.6 build 110401 Rel.47776n devices are prone to an authentication bypass vulnerability that allows remote attackers to view and modify administrative router settings by reading the HTML source code of the password.cgi file.
Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.
An issue was discovered in CommentsService.ashx in OnyakTech Comments Pro 3.8. An attacker can download a copy of the installer, decompile it, and discover a hardcoded IV used to encrypt the username and userid in the comment POST request. Additionally, the attacker can decrypt the encrypted encryption key (sent as a parameter in the comment form request) by setting this encrypted value as the username, which will appear on the comment page in its decrypted form. Using these two values (combined with the encryption functionality discovered in the decompiled installer), the attacker can encrypt another user's ID and username. These values can be used as part of the comment posting request in order to spoof the user.
An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
In Weidmueller Industrial WLAN devices in multiple versions the usage of hard-coded cryptographic keys within the service agent binary allows for the decryption of captured traffic across the network from or to the device.
An issue was discovered on FiberHome HG6245D devices through RP2613. There is a 6GFJdY4aAuUKJjdtSn7d password for the rdsadmin account.
The default administrator account & password of the EDIMAX wireless network camera is hard-coded. Remote attackers can disassemble firmware to obtain the privileged permission and further control the devices.
DFNDR Security Antivirus, Anti-hacking & Cleaner, 5.0.9, 2017-11-01, Android application uses a hard-coded key for encryption. Data stored using this key can be decrypted by anyone able to access this key.
A vulnerability involving insecure storage of sensitive information has been reported to affect QSW-M2116P-2T2S and QNAP switches running QuNetSwitch. If exploited, this vulnerability allows remote attackers to read sensitive information by accessing the unrestricted storage mechanism.We have already fixed this vulnerability in the following versions: QSW-M2116P-2T2S 1.0.6 build 210713 and later QGD-1600P: QuNetSwitch 1.0.6.1509 and later QGD-1602P: QuNetSwitch 1.0.6.1509 and later QGD-3014PT: QuNetSwitch 1.0.6.1519 and later
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
The IMM2 First Failure Data Capture function collects management module logs and diagnostic information when a hardware error is detected. This information is made available for download through an SFTP server hosted on the IMM2 management network interface. In versions earlier than 4.90 for Lenovo System x and earlier than 6.80 for IBM System x, the credentials to access the SFTP server are hard-coded and described in the IMM2 documentation, allowing an attacker with management network access to obtain the collected FFDC data. After applying the update, the IMM2 will create random SFTP credentials for use with OneCLI.
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
Hardcoded default root credentials exist on the ecobee3 lite 4.5.81.200 device. This allows a threat actor to gain access to the password-protected bootloader environment through the serial console.
atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The exported device configuration is encrypted with the hardcoded BpP+2R9*Q password in some cases.
dirary0.js on D-Link DIR-140L, DIR-640L devices allows remote unauthenticated attackers to discover admin credentials.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The exported device configuration is encrypted with the hardcoded Pxift* password in some cases.
An issue was discovered in the MensaMax (aka com.breustedt.mensamax) application 4.3 for Android. The use of a Hard-coded DES Cryptographic Key allows an attacker who decodes the application to decrypt transmitted data such as the login username and password.
The EPSON iPrint application 6.6.3 for Android contains hard-coded API and Secret keys for the Dropbox, Box, Evernote and OneDrive services.
A hardcoded secret key, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows attackers to access sensitive information.
A hardcoded passphrase, in CA Unified Infrastructure Management 8.5.1, 8.5, and 8.4.7, allows attackers to access sensitive information.
A reliance on a static, hard-coded credential in the design of the cloud-based storage system of Practecol's Guardzilla All-In-One Video Security System allows an attacker to view the private data of all users of the Guardzilla device.
An issue was discovered on FiberHome HG6245D devices through RP2613. The password for the enable command is gpon.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web management is done over HTTPS, using a hardcoded private key that has 0777 permissions.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
An issue was discovered on FiberHome HG6245D devices through RP2613. There is a password of four hexadecimal characters for the admin account. These characters are generated in init_3bb_password in libci_adaptation_layer.so.
spaces.htm on multiple D-Link devices (DSL, DIR, DWR) allows remote unauthenticated attackers to discover admin credentials.
QNAP F_VioCard 2312 and F_VioGate 2308 have hardcoded entries in authorized_keys files. NOTE: 1. All active models are not affected. The last affected model was EOL since 2010. 2. The legacy authorization mechanism is no longer adopted in all active models
An issue was discovered on FiberHome HG6245D devices through RP2613. The telnet daemon on port 23/tcp can be abused with the gpon/gpon credentials.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded f~i!b@e#r$h%o^m*esuperadmin / s(f)u_h+g|u credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. Credentials in /fhconf/umconfig.txt are obfuscated via XOR with the hardcoded *j7a(L#yZ98sSd5HfSgGjMj8;Ss;d)(*&^#@$a2s0i3g key. (The webs binary has details on how XOR is used.)
A Security Bypass vulnerability exists in TP-LINK IP Cameras TL-SC 3130, TL-SC 3130G, 3171G, 4171G, and 3130 1.6.18P12 due to default hard-coded credentials for the administrative Web interface, which could let a malicious user obtain unauthorized access to CGI files.
An issue was discovered on FiberHome HG6245D devices through RP2613. A hardcoded GEPON password for root is defined inside /etc/init.d/system-config.sh.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded user / user1234 credentials for an ISP.
Moxa EDR-G903 series routers with firmware before 2.11 have a hardcoded account, which allows remote attackers to obtain unspecified device access via unknown vectors.
An issue was discovered in svc-login.php in Void Aural Rec Monitor 9.0.0.1. Passwords are stored in unencrypted source-code text files. This was noted when accessing the svc-login.php file. The value is used to authenticate a high-privileged user upon authenticating with the server.
A use of hard-coded cryptographic key vulnerability in the SSLVPN of FortiOS before 7.0.1 may allow an attacker to retrieve the key by reverse engineering.
A vulnerability in the default configuration of the Simple Network Management Protocol (SNMP) feature of Cisco Wide Area Application Services (WAAS) Software could allow an unauthenticated, remote attacker to read data from an affected device via SNMP. The vulnerability is due to a hard-coded, read-only community string in the configuration file for the SNMP daemon. An attacker could exploit this vulnerability by using the static community string in SNMP version 2c queries to an affected device. A successful exploit could allow the attacker to read any data that is accessible via SNMP on the affected device. Note: The static credentials are defined in an internal configuration file and are not visible in the current operation configuration ('running-config') or the startup configuration ('startup-config'). Cisco Bug IDs: CSCvi40137.
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Usage of hard-coded cryptographic keys to encrypt configuration files and debug logs in FortiAuthenticator versions before 6.3.0 may allow an attacker with access to the files or the CLI configuration to decrypt the sensitive data, via knowledge of the hard-coded key.
An issue was discovered in Aviatrix Controller before 5.4.1204. It contains credentials unused by the software.
On the TP-Link TL-SG108E 1.0, there is a hard-coded ciphering key (a long string beginning with Ei2HNryt). This affects the 1.1.2 Build 20141017 Rel.50749 firmware.
Cisco IP Phone (VoIP) 7920 1.0(8) contains certain hard-coded ("fixed") public and private SNMP community strings that cannot be changed, which allows remote attackers to obtain sensitive information.
An issue was discovered on Athom Homey and Homey Pro devices before 5.0.0. ZigBee hub devices should generate a unique Standard Network Key that is then exchanged with all enrolled devices so that all inter-device communication is encrypted. However, the cited Athom products use another widely known key that is designed for testing purposes: "01030507090b0d0f00020406080a0c0d" (the decimal equivalent of 1 3 5 7 9 11 13 15 0 2 4 6 8 10 12 13), which is human generated and static across all issued devices.