Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2018-19070

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-07 Nov, 2018 | 18:00
Updated At-05 Aug, 2024 | 11:30
Rejected At-
Credits

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. They allow remote attackers to execute arbitrary OS commands via shell metacharacters in the usrName parameter of a CGIProxy.fcgi addAccount action.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:07 Nov, 2018 | 18:00
Updated At:05 Aug, 2024 | 11:30
Rejected At:
▼CVE Numbering Authority (CNA)

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. They allow remote attackers to execute arbitrary OS commands via shell metacharacters in the usrName parameter of a CGIProxy.fcgi addAccount action.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://sintonen.fi/advisories/foscam-ip-camera-multiple-vulnerabilities.txt
x_refsource_MISC
Hyperlink: https://sintonen.fi/advisories/foscam-ip-camera-multiple-vulnerabilities.txt
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://sintonen.fi/advisories/foscam-ip-camera-multiple-vulnerabilities.txt
x_refsource_MISC
x_transferred
Hyperlink: https://sintonen.fi/advisories/foscam-ip-camera-multiple-vulnerabilities.txt
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:07 Nov, 2018 | 18:29
Updated At:11 Dec, 2018 | 14:57

An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. They allow remote attackers to execute arbitrary OS commands via shell metacharacters in the usrName parameter of a CGIProxy.fcgi addAccount action.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.07.2HIGH
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Primary
Version: 3.0
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

opticam
opticam
>>i5_application_firmware>>2.21.1.128
cpe:2.3:o:opticam:i5_application_firmware:2.21.1.128:*:*:*:*:*:*:*
opticam
opticam
>>i5_system_firmware>>1.5.2.11
cpe:2.3:o:opticam:i5_system_firmware:1.5.2.11:*:*:*:*:*:*:*
opticam
opticam
>>i5>>-
cpe:2.3:h:opticam:i5:-:*:*:*:*:*:*:*
foscam
foscam
>>c2_application_firmware>>2.72.1.32
cpe:2.3:o:foscam:c2_application_firmware:2.72.1.32:*:*:*:*:*:*:*
foscam
foscam
>>c2_system_firmware>>1.11.1.8
cpe:2.3:o:foscam:c2_system_firmware:1.11.1.8:*:*:*:*:*:*:*
foscam
foscam
>>c2>>-
cpe:2.3:h:foscam:c2:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-78Primarynvd@nist.gov
CWE ID: CWE-78
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://sintonen.fi/advisories/foscam-ip-camera-multiple-vulnerabilities.txtcve@mitre.org
Exploit
Third Party Advisory
Hyperlink: https://sintonen.fi/advisories/foscam-ip-camera-multiple-vulnerabilities.txt
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

663Records found

CVE-2020-9463
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-5.44% / 89.79%
||
7 Day CHG~0.00%
Published-28 Feb, 2020 | 17:55
Updated-04 Aug, 2024 | 10:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Centreon 19.10 allows remote authenticated users to execute arbitrary OS commands via shell metacharacters in the server_ip field in JSON data in an api/internal.php?object=centreon_configuration_remote request.

Action-Not Available
Vendor-n/aCENTREON
Product-centreonn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-8654
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-89.90% / 99.55%
||
7 Day CHG~0.00%
Published-06 Feb, 2020 | 23:55
Updated-04 Aug, 2024 | 10:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in EyesOfNetwork 5.3. An authenticated web user with sufficient privileges could abuse the AutoDiscovery module to run arbitrary OS commands via the /module/module_frame/index.php autodiscovery.php target field.

Action-Not Available
Vendor-eyesofnetworkn/a
Product-eyesofnetworkn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0707
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-75.39% / 98.84%
||
7 Day CHG~0.00%
Published-16 Jul, 2018 | 15:00
Updated-16 Sep, 2024 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command injection vulnerability in change password of QNAP Q'center Virtual Appliance version 1.7.1063 and earlier could allow authenticated users to run arbitrary commands.

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-q\'centerQ'center Virtual Appliance
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0627
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-7.2||HIGH
EPSS-0.67% / 70.39%
||
7 Day CHG~0.00%
Published-09 Jan, 2019 | 22:00
Updated-05 Aug, 2024 | 03:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Aterm WG1200HP firmware Ver1.0.31 and earlier allows attacker with administrator rights to execute arbitrary OS commands via targetAPSsid parameter.

Action-Not Available
Vendor-NEC Corporation
Product-aterm_wg1200hp_firmwareaterm_wg1200hpWG1200HP
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-26075
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-9.34% / 92.44%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability exists in the console infactory_wlan functionality of InHand Networks InRouter302 V3.5.37. A specially-crafted series of network requests can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-8429
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.45% / 62.76%
||
7 Day CHG~0.00%
Published-11 Feb, 2020 | 17:15
Updated-04 Aug, 2024 | 09:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Admin web application in Kinetica 7.0.9.2.20191118151947 does not properly sanitise the input for the function getLogs. This lack of sanitisation could be exploited to allow an authenticated attacker to run remote code on the underlying operating system. The logFile parameter in the getLogs function was used as a variable in a command to read log files; however, due to poor input sanitisation, it was possible to bypass a replacement and break out of the command.

Action-Not Available
Vendor-kinetican/a
Product-kinetican/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0637
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-7.2||HIGH
EPSS-0.67% / 70.39%
||
7 Day CHG~0.00%
Published-09 Jan, 2019 | 22:00
Updated-05 Aug, 2024 | 03:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Aterm HC100RC Ver1.0.1 and earlier allows attacker with administrator rights to execute arbitrary OS commands via export.cgi encKey parameter.

Action-Not Available
Vendor-NEC Corporation
Product-aterm_hc100rc_firmwareaterm_hc100rcHC100RC
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-26420
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.9||CRITICAL
EPSS-9.34% / 92.44%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability exists in the console infactory_port functionality of InHand Networks InRouter302 V3.5.37. A specially-crafted series of network requests can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0293
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-2.04% / 83.11%
||
7 Day CHG~0.00%
Published-20 Jun, 2018 | 21:00
Updated-29 Nov, 2024 | 15:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in role-based access control (RBAC) for Cisco NX-OS Software could allow an authenticated, remote attacker to execute CLI commands that should be restricted for a nonadministrative user. The attacker would have to possess valid user credentials for the device. The vulnerability is due to incorrect RBAC privilege assignment for certain CLI commands. An attacker could exploit this vulnerability by authenticating to a device as a nonadministrative user and executing specific commands from the CLI. An exploit could allow the attacker to run commands that should be restricted to administrative users. These commands could modify the configuration or boot image on the device. This vulnerability affects MDS 9000 Series Multilayer Switches, Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCvd77904.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-nexus_56128pnexus_9332pqnexus_3132q-xnexus_93108tc-exnexus_3172tqnx-osnexus_9508nexus_3100-vnexus_3636c-rnexus_93120txnexus_n9k-x9636c-rnexus_93128txnexus_3548-xlnexus_31128pqnexus_6001pnexus_3164qnexus_5020nexus_3172tq-32tnexus_3132c-znexus_3524-xnexus_5548pnexus_5648qnexus_9272qnexus_5672upnexus_3264qnexus_34180ycnexus_3064-32tnexus_5596upnexus_3548nexus_3132qnexus_3016nexus_9372pxnexus_5696qnexus_92304qcnexus_92160yc-xnexus_n9k-x9636q-rnexus_n9k-c9508-fm-rmds_9100nexus_9504nexus_3048nexus_3524-xlnexus_9396txnexus_7000nexus_3172pqnexus_3064-xnexus_3232cnexus_5548upnexus_9396pxnexus_5010nexus_5000nexus_5596tnexus_3264c-enexus_9372txnexus_5624qnexus_3548-xnexus_3132q-xlnexus_3064-tnexus_93180yc-exnexus_6001tnexus_172tq-xlnexus_c36180yc-rnexus_9236cnexus_9516nexus_3172pq-xlnexus_7700Cisco NX-OS unknown
CWE ID-CWE-264
Not Available
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-8949
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-4.01% / 88.00%
||
7 Day CHG~0.00%
Published-12 Feb, 2020 | 18:21
Updated-04 Aug, 2024 | 10:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Gocloud S2A_WL 4.2.7.16471, S2A 4.2.7.17278, S2A 4.3.0.15815, S2A 4.3.0.17193, S3A K2P MTK 4.2.7.16528, S3A 4.3.0.16572, and ISP3000 4.3.0.17190 devices allows remote attackers to execute arbitrary OS commands via shell metacharacters in a ping operation, as demonstrated by the cgi-bin/webui/admin/tools/app_ping/diag_ping/; substring.

Action-Not Available
Vendor-gocloudn/a
Product-s2as2a_firmwares2a_wlisp3000_firmwares3aisp3000s3a_k2p_mtks2a_wl_firmwares3a_k2p_mtk_firmwares3a_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-26007
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-3.54% / 87.22%
||
7 Day CHG~0.00%
Published-12 May, 2022 | 17:01
Updated-15 Apr, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An OS command injection vulnerability exists in the console factory functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted network request can lead to command execution. An attacker can send a sequence of requests to trigger this vulnerability.

Action-Not Available
Vendor-InHand Networks, Inc.
Product-ir302_firmwareir302InRouter302
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0634
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-7.2||HIGH
EPSS-0.59% / 68.24%
||
7 Day CHG~0.00%
Published-09 Jan, 2019 | 22:00
Updated-05 Aug, 2024 | 03:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Aterm HC100RC Ver1.0.1 and earlier allows attacker with administrator rights to execute arbitrary OS commands via FactoryPassword parameter or bootmode parameter of a certain URL.

Action-Not Available
Vendor-NEC Corporation
Product-aterm_hc100rc_firmwareaterm_hc100rcHC100RC
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0629
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-7.2||HIGH
EPSS-0.67% / 70.39%
||
7 Day CHG~0.00%
Published-09 Jan, 2019 | 22:00
Updated-05 Aug, 2024 | 03:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Aterm W300P Ver1.0.13 and earlier allows attacker with administrator rights to execute arbitrary OS commands via HTTP request and response.

Action-Not Available
Vendor-NEC Corporation
Product-aterm_w300p_firmwareaterm_w300pAterm W300P
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-29937
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.79% / 72.91%
||
7 Day CHG~0.00%
Published-29 Apr, 2022 | 16:34
Updated-03 Aug, 2024 | 06:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

USU Oracle Optimization before 5.17.5 allows authenticated DataCollection users to achieve agent root access because some common OS commands are blocked but (for example) an OS command for base64 decoding is not blocked. NOTE: this is not an Oracle Corporation product.

Action-Not Available
Vendor-usun/a
Product-oracle_optimizationn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0424
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-1.12% / 77.34%
||
7 Day CHG~0.00%
Published-05 Oct, 2018 | 14:00
Updated-26 Nov, 2024 | 14:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco RV110W, RV130W, and RV215W Routers Management Interface Command Injection Vulnerability

A vulnerability in the web-based management interface of the Cisco RV110W Wireless-N VPN Firewall, Cisco RV130W Wireless-N Multifunction VPN Router, and Cisco RV215W Wireless-N VPN Router could allow an authenticated, remote attacker to execute arbitrary commands. The vulnerability is due to improper validation of user-supplied input to scripts by the web-based management interface. An attacker could exploit this vulnerability by sending malicious requests to a targeted device. A successful exploit could allow the attacker to execute arbitrary commands with the privileges of the root user.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-rv130w_firmwarerv215w_wireless-n_vpn_routerrv110w_firmwarerv130wrv110w_wireless-n_vpn_firewallrv215w_firmwareCisco RV130W Wireless-N Multifunction VPN Router Firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0631
Matching Score-4
Assigner-JPCERT/CC
ShareView Details
Matching Score-4
Assigner-JPCERT/CC
CVSS Score-7.2||HIGH
EPSS-0.67% / 70.39%
||
7 Day CHG~0.00%
Published-09 Jan, 2019 | 22:00
Updated-05 Aug, 2024 | 03:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Aterm W300P Ver1.0.13 and earlier allows attacker with administrator rights to execute arbitrary OS commands via targetAPSsid parameter.

Action-Not Available
Vendor-NEC Corporation
Product-aterm_w300p_firmwareaterm_w300pAterm W300P
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7389
Matching Score-4
Assigner-Rapid7, Inc.
ShareView Details
Matching Score-4
Assigner-Rapid7, Inc.
CVSS Score-5.5||MEDIUM
EPSS-4.83% / 89.10%
||
7 Day CHG~0.00%
Published-22 Jul, 2021 | 18:27
Updated-16 Sep, 2024 | 16:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Sage X3 Syracuse Missing Authentication for Critical Function in Developer Environment

Sage X3 System CHAINE Variable Script Command Injection. An authenticated user with developer access can pass OS commands via this variable used by the web application. Note, this developer configuration should not be deployed in production.

Action-Not Available
Vendor-sageSage
Product-x3syracuseX3
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0708
Matching Score-4
Assigner-QNAP Systems, Inc.
ShareView Details
Matching Score-4
Assigner-QNAP Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-68.14% / 98.53%
||
7 Day CHG~0.00%
Published-16 Jul, 2018 | 15:00
Updated-16 Sep, 2024 | 17:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command injection vulnerability in networking of QNAP Q'center Virtual Appliance version 1.7.1063 and earlier could allow authenticated users to run arbitrary commands.

Action-Not Available
Vendor-QNAP Systems, Inc.
Product-q\'centerQ'center Virtual Appliance
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-0348
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-7.2||HIGH
EPSS-0.36% / 57.39%
||
7 Day CHG~0.00%
Published-18 Jul, 2018 | 23:00
Updated-29 Nov, 2024 | 14:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the CLI of the Cisco SD-WAN Solution could allow an authenticated, remote attacker to inject arbitrary commands that are executed with root privileges. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by authenticating to the device and submitting malicious input to the load command within the VPN subsystem. The attacker must be authenticated to access the affected CLI parameter. A successful exploit could allow an attacker to execute commands with root privileges. This vulnerability affects the following Cisco products if they are running a release of the Cisco SD-WAN Solution prior to Release 18.3.0: vBond Orchestrator Software, vEdge 100 Series Routers, vEdge 1000 Series Routers, vEdge 2000 Series Routers, vEdge 5000 Series Routers, vEdge Cloud Router Platform, vManage Network Management Software, vSmart Controller Software. Cisco Bug IDs: CSCvi69866.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-vbond_orchestratorvedge_100mvedge-plusvedge-5000vsmart_controllervedge_100b_firmwarevedge_100wm_firmwarevedge-2000vmanage_network_managementvedge-100vedge_100bvedge-100_firmwarevedge-2000_firmwarevedge-provedge_100m_firmwarevedge-1000_firmwarevedge-5000_firmwarevedge-1000vedge_100wmCisco SD-WAN Solution unknown
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-27224
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-5.94% / 90.28%
||
7 Day CHG~0.00%
Published-09 May, 2022 | 14:29
Updated-03 Aug, 2024 | 05:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Galleon NTS-6002-GPS 4.14.103-Galleon-NTS-6002.V12 4. An authenticated attacker can perform command injection as root via shell metacharacters within the Network Tools section of the web-management interface. All three networking tools are affected (Ping, Traceroute, and DNS Lookup) and their respective input fields (ping_address, trace_address, nslookup_address).

Action-Not Available
Vendor-galsysn/a
Product-nts-6002-gpsnts-6002-gps_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7594
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-3.21% / 86.52%
||
7 Day CHG~0.00%
Published-21 Jan, 2020 | 21:05
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

MultiTech Conduit MTCDT-LVW2-24XX 1.4.17-ocea-13592 devices allow remote authenticated administrators to execute arbitrary OS commands by navigating to the Debug Options page and entering shell metacharacters in the interface JSON field of the ping function.

Action-Not Available
Vendor-multitechn/a
Product-conduit_mtcdt-lvw2-246aconduit_mtcdt-lvw2-246a_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-17406
Matching Score-4
Assigner-Zero Day Initiative
ShareView Details
Matching Score-4
Assigner-Zero Day Initiative
CVSS Score-8.8||HIGH
EPSS-44.28% / 97.47%
||
7 Day CHG~0.00%
Published-13 Oct, 2020 | 17:10
Updated-04 Aug, 2024 | 13:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Microhard Bullet-LTE prior to v1.2.0-r1112. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of the ping parameter provided to tools.sh. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-10595.

Action-Not Available
Vendor-microhardcorpMicrohard
Product-bullet-ltebullet-lte_firmwareBullet-LTE
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7244
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-8.08% / 91.80%
||
7 Day CHG~0.00%
Published-20 Jan, 2020 | 21:56
Updated-04 Aug, 2024 | 09:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Comtech Stampede FX-1010 7.4.3 devices allow remote authenticated administrators to achieve remote code execution by navigating to the Poll Routes page and entering shell metacharacters in the Router IP Address field. (In some cases, authentication can be achieved with the comtech password for the comtech account.)

Action-Not Available
Vendor-comtechteln/a
Product-stampede_fx-1010_firmwarestampede_fx-1010n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-1538
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-4.7||MEDIUM
EPSS-1.98% / 82.82%
||
7 Day CHG~0.00%
Published-04 Jun, 2021 | 16:45
Updated-07 Nov, 2024 | 22:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Common Services Platform Collector Command Injection Vulnerability

A vulnerability in the configuration dashboard of Cisco Common Services Platform Collector (CSPC) could allow an authenticated, remote attacker to execute arbitrary code. This vulnerability is due to insufficient sanitization of configuration entries. An attacker could exploit this vulnerability by logging in as a super admin and entering crafted input to configuration options on the CSPC configuration dashboard. A successful exploit could allow the attacker to execute remote code as root.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-common_services_platform_collectorCisco Common Services Platform Collector Software
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7351
Matching Score-4
Assigner-Rapid7, Inc.
ShareView Details
Matching Score-4
Assigner-Rapid7, Inc.
CVSS Score-7.3||HIGH
EPSS-69.96% / 98.61%
||
7 Day CHG~0.00%
Published-01 May, 2020 | 15:50
Updated-16 Sep, 2024 | 22:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Fonality Trixbox CE Post-Authentication Command Injection

An OS Command Injection vulnerability in the endpoint_devicemap.php component of Fonality Trixbox Community Edition allows an attacker to execute commands on the underlying operating system as the "asterisk" user. Note that Trixbox Community Edition has been unsupported by the vendor since 2012. This issue affects: Fonality Trixbox Community Edition, versions 1.2.0 through 2.8.0.4. Versions 1.0 and 1.1 are unaffected.

Action-Not Available
Vendor-netfortrisFonality
Product-trixboxTrixbox Community Edition
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7357
Matching Score-4
Assigner-Rapid7, Inc.
ShareView Details
Matching Score-4
Assigner-Rapid7, Inc.
CVSS Score-9.6||CRITICAL
EPSS-77.96% / 98.97%
||
7 Day CHG~0.00%
Published-06 Aug, 2020 | 15:45
Updated-17 Sep, 2024 | 03:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cayin CMS Command Injection

Cayin CMS suffers from an authenticated OS semi-blind command injection vulnerability using default credentials. This can be exploited to inject and execute arbitrary shell commands as the root user through the 'NTP_Server_IP' HTTP POST parameter in system.cgi page. This issue affects several branches and versions of the CMS application, including CME-SE, CMS-60, CMS-40, CMS-20, and CMS version 8.2, 8.0, and 7.5.

Action-Not Available
Vendor-CAYIN Technology Co.
Product-cms-se-lxccms-se-lxc_firmwarecms-secms-40cms-20_firmwarecmscms-60cms-se_firmwarecms-40_firmwarecms-60_firmwarecms-20Cayin CMS-20Cayin CMS-60Cayin CMS-40Cayin CMSCayin CMS-SE
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7361
Matching Score-4
Assigner-Rapid7, Inc.
ShareView Details
Matching Score-4
Assigner-Rapid7, Inc.
CVSS Score-9.6||CRITICAL
EPSS-35.97% / 96.97%
||
7 Day CHG~0.00%
Published-06 Aug, 2020 | 15:45
Updated-16 Sep, 2024 | 22:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ZenTao Pro Command Injection

The EasyCorp ZenTao Pro application suffers from an OS command injection vulnerability in its '/pro/repo-create.html' component. After authenticating to the ZenTao dashboard, attackers may construct and send arbitrary OS commands via the POST parameter 'path', and those commands will run in an elevated SYSTEM context on the underlying Windows operating system.

Action-Not Available
Vendor-easycorpEasyCorp
Product-zentao_proZenTao Pro
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-25017
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.1||CRITICAL
EPSS-2.95% / 85.92%
||
7 Day CHG~0.00%
Published-01 Apr, 2022 | 05:41
Updated-03 Aug, 2024 | 04:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Hitron CHITA 7.2.2.0.3b6-CD devices contain a command injection vulnerability via the Device/DDNS ddnsUsername field.

Action-Not Available
Vendor-hitrontechn/a
Product-chitachita_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7243
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-8.08% / 91.80%
||
7 Day CHG~0.00%
Published-20 Jan, 2020 | 21:56
Updated-04 Aug, 2024 | 09:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Comtech Stampede FX-1010 7.4.3 devices allow remote authenticated administrators to achieve remote code execution by navigating to the Fetch URL page and entering shell metacharacters in the URL field. (In some cases, authentication can be achieved with the comtech password for the comtech account.)

Action-Not Available
Vendor-comtechteln/a
Product-stampede_fx-1010_firmwarestampede_fx-1010n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-25048
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-19.03% / 95.09%
||
7 Day CHG~0.00%
Published-07 Jul, 2022 | 11:29
Updated-03 Aug, 2024 | 04:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command injection vulnerability in CWP v0.9.8.1126 that allows normal users to run commands as the root user.

Action-Not Available
Vendor-control-webpaneln/a
Product-webpaneln/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7242
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-8.08% / 91.80%
||
7 Day CHG~0.00%
Published-20 Jan, 2020 | 21:56
Updated-04 Aug, 2024 | 09:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Comtech Stampede FX-1010 7.4.3 devices allow remote authenticated administrators to achieve remote code execution by navigating to the Diagnostics Trace Route page and entering shell metacharacters in the Target IP address field. (In some cases, authentication can be achieved with the comtech password for the comtech account.)

Action-Not Available
Vendor-comtechteln/a
Product-stampede_fx-1010_firmwarestampede_fx-1010n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24388
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.85%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:30
Updated-16 Sep, 2024 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Privileged Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “date” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-23673
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-3.87% / 87.78%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 17:57
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7034
Matching Score-4
Assigner-Avaya, Inc.
ShareView Details
Matching Score-4
Assigner-Avaya, Inc.
CVSS Score-7.2||HIGH
EPSS-2.42% / 84.49%
||
7 Day CHG~0.00%
Published-23 Apr, 2021 | 20:15
Updated-16 Sep, 2024 | 23:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command injection in Avaya Session Border Controller for Enterprise

A command injection vulnerability in Avaya Session Border Controller for Enterprise could allow an authenticated, remote attacker to send specially crafted messages and execute arbitrary commands with the affected system privileges. Affected versions of Avaya Session Border Controller for Enterprise include 7.x, 8.0 through 8.1.1.x

Action-Not Available
Vendor-Avaya LLC
Product-session_border_controller_for_enterpriseSession Border Controller for Enterprise
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2018-13285
Matching Score-4
Assigner-Synology Inc.
ShareView Details
Matching Score-4
Assigner-Synology Inc.
CVSS Score-7.5||HIGH
EPSS-0.57% / 67.49%
||
7 Day CHG~0.00%
Published-01 Apr, 2019 | 14:26
Updated-17 Sep, 2024 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command injection vulnerability in ftpd in Synology Router Manager (SRM) before 1.1.7-6941-1 allows remote authenticated users to execute arbitrary OS commands via the (1) MKD or (2) RMD command.

Action-Not Available
Vendor-Synology, Inc.
Product-router_managerSynology Router Manager (SRM)
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23663
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.40%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:30
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23672
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-3.90% / 87.81%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 17:52
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-7237
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-46.81% / 97.59%
||
7 Day CHG~0.00%
Published-20 Jan, 2020 | 04:06
Updated-04 Aug, 2024 | 09:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Cacti 1.2.8 allows Remote Code Execution (by privileged users) via shell metacharacters in the Performance Boost Debug Log field of poller_automation.php. OS commands are executed when a new poller cycle begins. The attacker must be authenticated, and must have access to modify the Performance Settings of the product.

Action-Not Available
Vendor-n/aThe Cacti Group, Inc.
Product-cactin/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-23665
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-9.1||CRITICAL
EPSS-2.39% / 84.40%
||
7 Day CHG~0.00%
Published-16 May, 2022 | 19:40
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A authenticated remote command injection vulnerability was discovered in Aruba ClearPass Policy Manager version(s): 6.10.4 and below, 6.9.9 and below, 6.8.9-HF2 and below, 6.7.x and below. Aruba has released updates to ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-5756
Matching Score-4
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-4
Assigner-Tenable Network Security, Inc.
CVSS Score-8.8||HIGH
EPSS-1.76% / 81.82%
||
7 Day CHG~0.00%
Published-17 Jul, 2020 | 20:16
Updated-04 Aug, 2024 | 08:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router.

Action-Not Available
Vendor-grandstreamTenable, Inc.
Product-gwn7000gwn7000_firmwareGrandstream GWN7000
CWE ID-CWE-489
Active Debug Code
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24393
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.68% / 70.73%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:24
Updated-16 Sep, 2024 | 23:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in Fidelis Network and Deception CommandPost enables authenticated command injection through the web interface using the “check_vertica_upgrade” value for the “cpIp” parameter. The vulnerability could allow a specially crafted HTTP request to execute system commands on the CommandPost and return results in an HTTP response via an authenticated session. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-5791
Matching Score-4
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-4
Assigner-Tenable Network Security, Inc.
CVSS Score-7.2||HIGH
EPSS-91.26% / 99.64%
||
7 Day CHG~0.00%
Published-20 Oct, 2020 | 21:22
Updated-04 Aug, 2024 | 08:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper neutralization of special elements used in an OS command in Nagios XI 5.7.3 allows a remote, authenticated admin user to execute operating system commands with the privileges of the apache user.

Action-Not Available
Vendor-n/aNagios Enterprises, LLC
Product-nagios_xiNagios XI
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-5758
Matching Score-4
Assigner-Tenable Network Security, Inc.
ShareView Details
Matching Score-4
Assigner-Tenable Network Security, Inc.
CVSS Score-8.8||HIGH
EPSS-5.19% / 89.53%
||
7 Day CHG~0.00%
Published-17 Jul, 2020 | 20:35
Updated-04 Aug, 2024 | 08:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Grandstream UCM6200 series firmware version 1.0.20.23 and below is vulnerable to OS command injection via HTTP. An authenticated remote attacker can execute commands as the root user by sending a crafted HTTP GET to the UCM's "Old" HTTPS API.

Action-Not Available
Vendor-grandstreamn/a
Product-ucm6202_firmwareucm6204_firmwareucm6208_firmwareucm6202ucm6204ucm6208Grandstream UCM6200 Series
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-24389
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
ShareView Details
Matching Score-4
Assigner-Fidelis Cybersecurity, Inc.
CVSS Score-8.8||HIGH
EPSS-0.84% / 73.85%
||
7 Day CHG~0.00%
Published-17 May, 2022 | 19:28
Updated-16 Sep, 2024 | 18:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authenticated Privileged Command Injection Vulnerability in Fidelis Network and Deception

Vulnerability in rconfig “cert_utils” enables an attacker with user level access to the CLI to inject root level commands into Fidelis Network and Deception CommandPost, Collector, Sensor, and Sandbox components as well as neighboring Fidelis components. The vulnerability is present in Fidelis Network and Deception versions prior to 9.4.5. Patches and updates are available to address this vulnerability.

Action-Not Available
Vendor-fidelissecurityFidelis Cybersecurity
Product-deceptionnetworkFidelis DeceptionFidelis Network
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-6842
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-2.09% / 83.33%
||
7 Day CHG~0.00%
Published-21 Feb, 2020 | 15:55
Updated-04 Aug, 2024 | 09:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DCH-M225 1.05b01 and earlier devices allow remote authenticated admins to execute arbitrary OS commands via shell metacharacters in the media renderer name.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dch-m225dch-m225_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-4242
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-8.8||HIGH
EPSS-4.08% / 88.10%
||
7 Day CHG~0.00%
Published-31 Mar, 2020 | 14:31
Updated-16 Sep, 2024 | 20:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Spectrum Scale and IBM Spectrum Protect Plus 10.1.0 through 10.1.5 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially crafted request, an attacker could exploit this vulnerability to execute arbitrary commands on the system. IBM X-Force ID: 175419.

Action-Not Available
Vendor-IBM Corporation
Product-spectrum_scalespectrum_protect_plusSpectrum Protect Plus
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-2253
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.1||CRITICAL
EPSS-0.49% / 64.72%
||
7 Day CHG~0.00%
Published-01 Jul, 2022 | 14:56
Updated-16 Apr, 2025 | 17:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Distributed Data Systems WebHMI OS Command Injection

A user with administrative privileges in Distributed Data Systems WebHMI 4.1.1.7662 may send OS commands to execute on the host server.

Action-Not Available
Vendor-webhmiDistributed Data Systems
Product-webhmi_firmwarewebhmiWebHMI
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-7175
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.9||CRITICAL
EPSS-21.42% / 95.49%
||
7 Day CHG~0.00%
Published-10 Jul, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NfSen before 1.3.8 allows remote attackers to execute arbitrary OS commands via shell metacharacters in the customfmt parameter (aka the "Custom output format" field).

Action-Not Available
Vendor-nfsenn/a
Product-nfsenn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-5146
Matching Score-4
Assigner-SonicWall, Inc.
ShareView Details
Matching Score-4
Assigner-SonicWall, Inc.
CVSS Score-7.2||HIGH
EPSS-2.25% / 83.95%
||
7 Day CHG~0.00%
Published-09 Jan, 2021 | 00:15
Updated-04 Aug, 2024 | 08:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in SonicWall SMA100 appliance allow an authenticated management-user to perform OS command injection using HTTP POST parameters. This vulnerability affected SMA100 Appliance version 10.2.0.2-20sv and earlier.

Action-Not Available
Vendor-SonicWall Inc.
Product-sma_100_firmwaresma_100SMA100
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-5350
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-7.9||HIGH
EPSS-3.68% / 87.45%
||
7 Day CHG~0.00%
Published-15 Apr, 2020 | 18:00
Updated-16 Sep, 2024 | 17:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC Integrated Data Protection Appliance versions 2.0, 2.1, 2.2, 2.3, 2.4 contain a command injection vulnerability in the ACM component. A remote authenticated malicious user with root privileges could inject parameters in the ACM component APIs that could lead to manipulation of passwords and execution of malicious commands on ACM component.

Action-Not Available
Vendor-Dell Inc.
Product-emc_integrated_data_protection_applianceIntegrated Data Protection Appliance
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • 13
  • 14
  • Next
Details not found