COMMAX Smart Home System allows an unauthenticated attacker to change configuration and cause denial-of-service through the setconf endpoint. Attackers can trigger a denial-of-service scenario by sending a malformed request to the setconf endpoint.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor service.
TadTools special page is vulnerable to authorization bypass, thus remote attackers can use the specific parameter to delete arbitrary files in the system without logging in.
An issue was discovered on Belkin Wemo Switch 28B WW_2.00.11057.PVT-OWRT-SNS devices. They allow remote attackers to cause a denial of service (persistent rules-processing outage) via a crafted ruleDbBody element in a StoreRules request to the upnp/control/rules1 URI, because database corruption occurs.
A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) Supervisor, Cisco UCS Director, and Cisco UCS Director Express for Big Data could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition. The vulnerability is due to a missing authentication check in an API call. An attacker who can send a request to an affected system could cause all currently authenticated users to be logged off. Repeated exploitation could cause the inability to maintain a session in the web-based management portal.
Missing authentication for critical function exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier, which may allow a remote unauthenticated attacker to execute some critical functions without authentication, e.g., rebooting the product.
Tinycontrol LAN Controller v3 (LK3) firmware versions up to 1.58a (hardware v3.8) contain a missing authentication vulnerability in the stm.cgi endpoint. A remote, unauthenticated attacker can send crafted requests to forcibly reboot the device or restore factory settings, leading to a denial of service and configuration loss.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
Missing Authentication for Critical Function in SICK Flexi Classic and Flexi Soft Gateways with Partnumbers 1042193, 1042964, 1044078, 1044072, 1044073, 1044074, 1099830, 1099832, 1127717, 1069070, 1112296, 1051432, 1102420, 1127487, 1121596, 1121597 allows an unauthenticated remote attacker to influence the availability of the device by changing the IP settings of the device via broadcasted UDP packets.
Western Digital WD My Book Live (2.x and later) and WD My Book Live Duo (all versions) have an administrator API that can perform a system factory restore without authentication, as exploited in the wild in June 2021, a different vulnerability than CVE-2018-18472.
free5GC is an open-source implementation of the 5G core network. Prior to 4.2.2, free5GC's SMF mounts the UPI management route group without inbound OAuth2 middleware. The POST /upi/v1/upNodesLinks create-or-update handler accepts attacker-controlled JSON and passes it directly into UpNodesFromConfiguration(), which calls logger.InitLog.Fatalf(...) on several validation failures. One confirmed path is the UE-IP-pool overlap check: a single unauthenticated POST that adds a new UPF whose pool overlaps an existing UPF terminates the entire SMF process (docker ps shows Exited (1)), not just the goroutine. This vulnerability is fixed in 4.2.2.
In D-link DIR-816 A2_v1.10CNB04.img,the network can be reset without authentication via /goform/setMAC.
NLTK (Natural Language Toolkit) is a suite of open source Python modules, data sets, and tutorials supporting research and development in Natural Language Processing. In versions 3.9.3 and prior, `nltk.app.wordnet_app` allows unauthenticated remote shutdown of the local WordNet Browser HTTP server when it is started in its default mode. A simple `GET /SHUTDOWN%20THE%20SERVER` request causes the process to terminate immediately via `os._exit(0)`, resulting in a denial of service. Commit bbaae83db86a0f49e00f5b0db44a7254c268de9b patches the issue.
Telesquare SKT LTE Router SDT-CS3B1 software version 1.2.0 contains an unauthenticated remote reboot vulnerability that allows attackers to trigger device reboot without authentication. Attackers can send POST requests to the lte.cgi endpoint with the Command=Reboot parameter to cause denial of service by forcing the router to restart.
One of the usage insights HTTP API endpoints in Grafana Enterprise 6.x before 6.7.6, 7.x before 7.3.10, and 7.4.x before 7.4.5 is accessible without any authentication. This allows any unauthenticated user to send an unlimited number of requests to the endpoint, leading to a denial of service (DoS) attack against a Grafana Enterprise instance.
SiYuan is a personal knowledge management system. Prior to version 3.6.2, the SiYuan kernel WebSocket server accepts unauthenticated connections when a specific "auth keepalive" query parameter is present. After connection, incoming messages are parsed using unchecked type assertions on attacker-controlled JSON. A remote attacker can send malformed messages that trigger a runtime panic, potentially crashing the kernel process and causing denial of service. Version 3.6.2 fixes the issue.
An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (TCP).
An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via HTTP.
The reminder module lacks an authentication mechanism for broadcasts received. Successful exploitation of this vulnerability may affect availability.
Core FTP 2.0 build 653 contains a denial of service vulnerability in the PBSZ command that allows unauthenticated attackers to crash the service by sending a malformed command with an oversized buffer. Attackers can send a PBSZ command with a payload exceeding 211 bytes to trigger an access violation and crash the FTP server process.
The Web Management of TP-Link TP-SG105E V4 1.0.0 Build 20181120 devices allows an unauthenticated attacker to reboot the device via a reboot.cgi request.
VPN Browser+ 1.1.0.0 contains a denial of service vulnerability that allows unauthenticated attackers to crash the application by submitting oversized input through the search functionality. Attackers can paste a large buffer of characters into the search bar to trigger an unhandled exception that terminates the application.
Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14.
A vulnerability was found in SimStudioAI sim up to 37786d371e17d35e0764e1b5cd519d873d90d97b. It has been declared as critical. Affected by this vulnerability is the function POST of the file apps/sim/app/api/files/upload/route.ts of the component Session Handler. The manipulation of the argument Request leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Vulnerability in the Oracle Financial Services Analytical Applications Infrastructure product of Oracle Financial Services Applications (component: System Configuration). Supported versions that are affected are 8.0.7.9, 8.0.8.7 and 8.1.2.5. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Financial Services Analytical Applications Infrastructure. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of Oracle Financial Services Analytical Applications Infrastructure. CVSS 3.1 Base Score 7.5 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 14.1.1.0.0 and 14.1.2.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP/2 to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized ability to cause a hang or frequently repeatable crash (complete DOS) of Oracle WebLogic Server. CVSS 3.1 Base Score 7.5 (Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
The Chaos Controller Manager in Chaos Mesh exposes a GraphQL debugging server without authentication to the entire Kubernetes cluster, which provides an API to kill arbitrary processes in any Kubernetes pod, leading to cluster-wide denial of service.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP USB Function functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted network packet can lead to a denial of service. An attacker can send an unauthenticated packet to trigger this vulnerability.This vulnerability is specific to the malicious message sent via Modbus TCP over port 502.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a sequence of Modbus RTU over TCP messages to port 503 using the Write Single Register function code (6). The attack sequence begins with a message to register 58112 with a value of 1000, indicating that a configuration change will follow. Next, a message is sent to register 29440 with a value corresponding to the new Modbus address to be configured. Finally, a message to register 57856 with a value of 161 commits the configuration change. After this configuration change, the device will be in a denial-of-service state.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a single Modbus TCP message to port 503 using the Write Single Register function code (6) to write the value 1 to register 4352. This action changes the Modbus address to 15. After this message is sent, the device will be in a denial-of-service state.
An issue in the component tpi_systool_handle(0) (/goform/SysToolReboot) of Tenda W6-S v1.0.0.4(510) allows unauthenticated attackers to arbitrarily reboot the device.
DuraComm SPM-500 DP-10iN-100-MU lacks access controls for a function that should require user authentication. This could allow an attacker to repeatedly reboot the device.
An issue in the component tpi_systool_handle(0) (/goform/SysToolRestoreSet) of Tenda W6-S v1.0.0.4(510) allows unauthenticated attackers to arbitrarily reboot the device.
The endpoint hosts a script that allows an unauthorized remote attacker to put the system in a fail-safe state over the network due to missing authentication.
A vulnerability in the MSC800 allows an unauthenticated attacker to modify the product’s IP address over Sopas ET. This can lead to Denial of Service. Users are recommended to upgrade both MSC800 and MSC800 LFT to version V4.26 and S2.93.20 respectively which fixes this issue.
Vulnerability in the Oracle WebLogic Server component of Oracle Fusion Middleware (subcomponent: WLS Security). Supported versions that are affected are 10.3.6.0.0, 12.1.3.0.0, 12.2.1.1.0 and 12.2.1.2.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3 to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in takeover of Oracle WebLogic Server. CVSS 3.0 Base Score 7.5 (Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
Quest KACE Systems Management Appliance (SMA) 13.0.x before 13.0.385, 13.1.x before 13.1.81, 13.2.x before 13.2.183, 14.0.x before 14.0.341 (Patch 5), and 14.1.x before 14.1.101 (Patch 4) allows unauthenticated users to replace system licenses through a web interface intended for license renewal. Attackers can exploit this to replace valid licenses with expired or trial licenses, causing denial of service.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP USB Function functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted network packet can lead to a denial of service. An attacker can send an unauthenticated packet to trigger this vulnerability.This vulnerability is specific to the malicious message sent via Modbus RTU over TCP on port 503.
BKG Professional NtripCaster 2.0.39 allows querying information over the UDP protocol without authentication. The NTRIP sourcetable is typically quite long (tens of kBs) and can be requested with a packet of only 30 bytes. This presents a vector that can be used for UDP amplification attacks. Normally, only authenticated streaming data will be provided over UDP and not the sourcetable.
WWBN AVideo is an open source video platform. In versions 26.0 and prior, the AVideo on_publish_done.php endpoint in the Live plugin allows unauthenticated users to terminate any active live stream. The endpoint processes RTMP callback events to mark streams as finished in the database, but performs no authentication or authorization checks before doing so. An attacker can enumerate active stream keys from the unauthenticated stats.json.php endpoint, then send crafted POST requests to on_publish_done.php to terminate any live broadcast. This enables denial-of-service against all live streaming functionality on the platform. At time of publication, there are no publicly available patches.
An improper authentication for critical function issue in Hitachi Kokusai Electric Network products for monitoring system (Camera, Decoder and Encoder) and bellow allows attckers to remotely reboot the device via a crafted POST request to the endpoint /ptipupgrade.cgi. Security information ID hitachi-sec-2022-001 contains fixes for the issue.
A denial of service vulnerability exists in the Modbus TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted network packet can lead to denial of service. An attacker can send an unauthenticated packet to trigger this vulnerability.
An exploitable denial-of-service vulnerability exists in the UDPRelay functionality of Shadowsocks-libev 3.3.2. When utilizing a Stream Cipher and a local_address, arbitrary UDP packets can cause a FATAL error code path and exit. An attacker can send arbitrary UDP packets to trigger this vulnerability.
Hydra is a Continuous Integration service for Nix based projects. It is possible to trigger evaluations in Hydra without any authentication. Depending on the size of evaluations, this can impact the availability of systems. The problem can be fixed by applying https://github.com/NixOS/hydra/commit/f73043378907c2c7e44f633ad764c8bdd1c947d5 to any Hydra package. Users are advised to upgrade. Users unable to upgrade should deny the `/api/push` route in a reverse proxy. This also breaks the "Evaluate jobset" button in the frontend.
Due to missing authentication check, SAP Business one License service API - version 10.0 allows an unauthenticated attacker to send malicious http requests over the network. On successful exploitation, an attacker can break the whole application making it inaccessible.
An incorrect API discovered in Signify Wiz Connected 1.9.1 allows attackers to remotely launch a DoS on Wiz devices only requiring the MAC address.
A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a single Modbus TCP message to port 502 using the Write Single Register function code (6) to write the value 1 to register 4352. This action changes the Modbus address to 15. After this message is sent, the device will be in a denial-of-service state.
Sliver is a command and control framework that uses a custom Wireguard netstack. Prior to 1.7.0, the DNS C2 listener accepts unauthenticated TOTP bootstrap messages and allocates server-side DNS sessions without validating OTP values, even when EnforceOTP is enabled. Because sessions are stored without a cleanup/expiry path in this flow, an unauthenticated remote actor can repeatedly create sessions and drive memory exhaustion. This vulnerability is fixed in 1.7.0.
An access control issue in the component /ManageRoute/postRoute of FreeTAKServer v1.9.8 allows unauthenticated attackers to cause a Denial of Service (DoS) via an unusually large amount of created routes, or create unsafe or false routes for legitimate users.
JUNG Smart Visu Server 1.1.1050 contains a denial of service vulnerability that allows unauthenticated attackers to remotely shutdown or reboot the server. Attackers can send a single POST request to trigger the server reboot without requiring any authentication.