The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
A vulnerability was found in shsuishang ShopSuite ModulithShop up to 45a99398cec3b7ad7ff9383694f0b53339f2d35a. Affected by this issue is some unknown functionality of the component RSA/OAuth2/Database. The manipulation results in hard-coded credentials. The attack can be executed remotely. The exploit has been made public and could be used. This product implements a rolling release for ongoing delivery, which means version information for affected or updated releases is unavailable.
Swann SWWHD-INTCAM-HD devices have the twipc root password, leading to FTP access as root. NOTE: all affected customers were migrated by 2020-08-31.
A security vulnerability has been detected in AstrBotDevs AstrBot up to 4.16.0. This issue affects some unknown processing of the file astrbot/dashboard/routes/auth.py of the component Dashboard. The manipulation leads to hard-coded credentials. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
IBM Security Identity Governance and Intelligence 5.2 through 5.2.4.1 Virtual Appliance contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 153386.
Deltek Vision 7.x before 7.6 permits the execution of any attacker supplied SQL statement through a custom RPC over HTTP protocol. The Vision system relies on the client binary to enforce security rules and integrity of SQL statements and other content being sent to the server. Client HTTP calls can be manipulated by one of several means to execute arbitrary SQL statements (similar to SQLi) or possibly have unspecified other impact via this custom protocol. To perform these attacks an authenticated session is first required. In some cases client calls are obfuscated by encryption, which can be bypassed due to hard-coded keys and an insecure key rotation protocol. Impacts may include remote code execution in some deployments; however, the vendor states that this cannot occur when the installation documentation is heeded.
IBM Security Guardium 10 and 10.5 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 150022.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. The CGIProxy.fcgi?cmd=setTelnetSwitch feature is authorized for the root user with a password of toor.
Hardcoded credentials in the Ricoh myPrint application 2.9.2.4 for Windows and 2.2.7 for Android give access to any externally disclosed myPrint WSDL API, as demonstrated by discovering API secrets of related Google cloud printers, encrypted passwords of mail servers, and names of printed files.
A hidden backdoor on PATLITE NH-FB Series devices with firmware version 1.45 or earlier, NH-FV Series devices with firmware version 1.10 or earlier, and NBM Series devices with firmware version 1.09 or earlier allow attackers to enable an SSH daemon via the "kankichi" or "kamiyo4" password to the _secret1.htm URI. Subsequently, the default password of root for the root account allows an attacker to conduct remote code execution and as a result take over the system.
An issue was discovered on Foscam C2 devices with System Firmware 1.11.1.8 and Application Firmware 2.72.1.32, and Opticam i5 devices with System Firmware 1.5.2.11 and Application Firmware 2.21.1.128. There is a hardcoded Ak47@99 password for the factory~ account.
A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has been published and may be used. Upgrading to version 5.7.1 is sufficient to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
The Oracle WebCenter Interaction 10.3.3 search service queryd.exe binary is compiled with the i1g2s3c4 hardcoded password. Authentication to the Oracle WCI search service uses this hardcoded password and cannot be customised by customers. An adversary able to access this service over a network could perform search queries to extract large quantities of sensitive information from the WCI installation. NOTE: this CVE is assigned by MITRE and isn't validated by Oracle because Oracle WebCenter Interaction Portal is out of support.
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
An attacker without authentication can login with default credentials for privileged users in Eltex ESP-200 firmware version 1.2.0.
A vulnerability in the Cisco Small Business Switches software could allow an unauthenticated, remote attacker to bypass the user authentication mechanism of an affected device. The vulnerability exists because under specific circumstances, the affected software enables a privileged user account without notifying administrators of the system. An attacker could exploit this vulnerability by using this account to log in to an affected device and execute commands with full admin rights. Cisco has not released software updates that address this vulnerability. This advisory will be updated with fixed software information once fixed software becomes available. There is a workaround to address this vulnerability.
Logitech Harmony Hub before version 4.15.206 contained two hard-coded accounts in the XMPP server that gave remote users access to the local API.
POSIM EVO 15.13 for Windows includes hardcoded database credentials for the "root" database user. "root" access to POSIM EVO's database may result in a breach of confidentiality, integrity, or availability or allow for attackers to remotely execute code on associated POSIM EVO clients.
A vulnerability in Cisco Video Surveillance Manager (VSM) Software running on certain Cisco Connected Safety and Security Unified Computing System (UCS) platforms could allow an unauthenticated, remote attacker to log in to an affected system by using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, default, static user credentials for the root account of the affected software on certain systems. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
A vulnerability in the install function of Cisco Prime Collaboration Provisioning (PCP) could allow an unauthenticated, remote attacker to access the administrative web interface using a default hard-coded username and password that are used during install. The vulnerability is due to a hard-coded password that, in some cases, is not replaced with a unique password. A successful exploit could allow the attacker to access the administrative web interface with administrator-level privileges.
Invoxia NVX220 devices allow TELNET access as admin with a default password.
Harmonic NSG 9000 devices have a default password of nsgadmin for the admin account, a default password of nsgguest for the guest account, and a default password of nsgconfig for the config account.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
The server API in the Anda app relies on hardcoded credentials.
Sollae Serial-Ethernet-Module and Remote-I/O-Device-Server devices have a default password of sollae for the TELNET service.
Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Use of a Hard-coded Cryptographic Key used to protect cookie session data in /var/www/xms/application/config/config.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to bypass authentication.
A hard-coded password vulnerability was discovered in vApp Manager which is embedded in Dell EMC Unisphere for VMAX, Dell EMC Solutions Enabler, Dell EMC VASA Virtual Appliances, and Dell EMC VMAX Embedded Management (eManagement): Dell EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.18, Dell EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.21, Dell EMC VASA Virtual Appliance versions prior to 8.4.0.514, and Dell EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier). They contain an undocumented default account (smc) with a hard-coded password that may be used with certain web servlets. A remote attacker with the knowledge of the hard-coded password and the message format may use vulnerable servlets to gain unauthorized access to the system. Note: This account cannot be used to log in via the web user interface.
Use of Hard-coded Credentials in /var/www/xms/application/controllers/gatherLogs.php in the administrative console in Dialogic PowerMedia XMS through 3.5 allows remote attackers to interact with a web service.
ASUSTOR ADM 3.1.0.RFQ3 uses the same default root:admin username and password as it does for the NAS itself for applications that are installed from the online repository. This may allow an attacker to login and upload a webshell.
Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account.
A design flaw in the Trane ComfortLink II SCC firmware version 2.0.2 service allows remote attackers to take complete control of the system.
iBaby M3S has a password of admin for the backdoor admin account.
The Web Panel in Netsweeper before 4.0.5 has a default password of branding for the branding account, which makes it easier for remote attackers to obtain access via a request to webadmin/.
TRENDnet TEW-823DRU devices with firmware before 1.00b36 have a hardcoded password of kcodeskcodes for the root account, which makes it easier for remote attackers to obtain access via an FTP session.
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
Telesquare SDT-CS3B1 and SDT-CW3B1 devices through 1.2.0 have a default factory account. Remote attackers can obtain access to the device via TELNET using a hardcoded account.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded awnfibre / fibre@dm!n credentials for an ISP.
Softing FG-100 PB PROFIBUS firmware version FG-x00-PB_V2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / CUadmin credentials for an ISP.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded trueadmin / admintrue credentials for an ISP.
A vulnerability was found in demozx gf_cms 1.0/1.0.1. It has been classified as critical. This affects the function init of the file internal/logic/auth/auth.go of the component JWT Authentication. The manipulation leads to hard-coded credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.2 is able to address this issue. The patch is named be702ada7cb6fdabc02689d90b38139c827458a5. It is recommended to upgrade the affected component.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded useradmin / 888888 credentials for an ISP.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains credentials for an ISP that equal the last part of the MAC address of the br0 interface.
The MySQL server in Juniper Networks Junos Space before 13.3R1.8 has an unspecified account with a hardcoded password, which allows remote attackers to obtain sensitive information and consequently obtain administrative control by leveraging database access.
Emerson DeltaV 10.3.1, 11.3, 11.3.1, and 12.3 uses hardcoded credentials for diagnostic services, which allows remote attackers to bypass intended access restrictions via a TCP session, as demonstrated by a session that uses the telnet program.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded L1vt1m4eng / 888888 credentials for an ISP.