Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user.
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.
A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file.
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.
A CWE-321: Use of hard-coded cryptographic key stored in cleartext vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker to decrypt a password.
A CWE-316: Cleartext Storage of Sensitive Information in Memory vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker access to login credentials.
A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to read user credentials.
A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide.
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure.
Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4.
An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system's path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges.
A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)
Incorrect Default Permission vulnerability exists in SoMove (V2.8.1) and prior which could cause elevation of privilege and provide full access control to local system users to SoMove component and services when a SoMove installer script is launched.
CWE-276: Incorrect Default Permissions vulnerability exists that could allow an authenticated user with access to the device’s web interface to perform unauthorized file and firmware uploads when crafting custom web requests.
in OpenHarmony v3.2.2 and prior versions allow a local attacker get confidential information through incorrect default permissions.
Open-iSCSI targetcli-fb through 2.1.52 has weak permissions for /etc/target (and for the backup directory and backup files).
Icinga 2 is an open source monitoring system. Starting in version 2.3.0 and prior to versions 2.13.14, 2.14.8, and 2.15.2, the Icinga 2 MSI did not set appropriate permissions for the `%ProgramData%\icinga2\var` folder on Windows. This resulted in the its contents - including the private key of the user and synced configuration - being readable by all local users. All installations on Windows are affected. Versions 2.13.14, 2.14.8, and 2.15.2 contains a fix. There are two possibilities to work around the issue without upgrading Icinga 2. Upgrade Icinga for Windows to at least version v1.13.4, v1.12.4, or v1.11.2. These version will automatically fix the ACLs for the Icinga 2 agent as well. Alternatively, manually update the ACL for the given folder `C:\ProgramData\icinga2\var` (and `C:\Program Files\WindowsPowerShell\modules\icinga-powershell-framework\certificate` to fix the issue for the Icinga for Windows as well) including every sub-folder and item to restrict access for general users, only allowing the Icinga service user and administrators access.
A permissions issue was addressed with additional restrictions. This issue is fixed in tvOS 17.1, watchOS 10.1, macOS Sonoma 14.1, iOS 17.1 and iPadOS 17.1. An app may be able to access sensitive user data.
Incorrect default permissions for the Intel(R) Support Android application before 21.07.40 may allow an authenticated user to potentially enable information disclosure via local access.
A permissions issue was addressed with additional restrictions. This issue is fixed in macOS Sonoma 14.1. An app may gain unauthorized access to Bluetooth.
An issue was discovered in the IGEL Universal Management Suite (UMS) 6.07.100. Insecure permissions for the serverconfig registry key (under JavaSoft\Prefs\de\igel\rm\config in HKEY_LOCAL_MACHINE\SOFTWARE) allow an unprivileged local attacker to read the encrypted dbuser and dbpassword values for the UMS superuser.
A flaw was found in Red Hat AMQ Broker Operator, where it displayed a password defined in ActiveMQArtemisAddress CR, shown in plain text in the Operator Log. This flaw allows an authenticated local attacker to access information outside of their permissions.
PendingIntent hijacking vulnerability in Weather application prior to SMR Mar-2022 Release 1 allows local attackers to perform unauthorized action without permission via hijacking the PendingIntent.
In createPendingIntent of CredentialManagerUi.java, there is a possible way to access credentials from other users due to a permissions bypass. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
IBM QRadar SIEM 7.3, 7.4, and 7.5 could allow a local user to obtain sensitive information from the TLS key file due to incorrect file permissions. IBM X-Force ID: 223597.
log4js-node is a port of log4js to node.js. In affected versions default file permissions for log files created by the file, fileSync and dateFile appenders are world-readable (in unix). This could cause problems if log files contain sensitive information. This would affect any users that have not supplied their own permissions for the files via the mode parameter in the config. Users are advised to update.
Incorrect default permission in Galaxy Wearable prior to version 2.2.68.26 allows local attackers to access sensitive information.
In buzzBeepBlinkLocked of NotificationManagerService.java, there is a possible way to share data across users due to a permissions bypass. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-10 Android-11 Android-12 Android-12L Android-13Android ID: A-237540408
A flaw was found in libvirt. External inactive snapshots for shut-down VMs are incorrectly created as world-readable, making it possible for unprivileged users to inspect the guest OS contents. This results in an information disclosure vulnerability.
In bindWallpaperComponentLocked of WallpaperManagerService.java, there is a possible permission bypass due to an unsafe PendingIntent. This could lead to local escalation of privilege with User execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-10 Android-8.0 Android-8.1 Android-9Android ID: A-154915372
Incorrect default permissions in FactoryCamera prior to SMR May-2026 Release 1 allows local attacker to access unique identifier.
A permission bypass vulnerability in Huawei cross device task management could allow an attacker to access certain resource in the attacked devices. Affected product versions include:JAD-AL50 versions 102.0.0.225(C00E220R3P4).
In Red Hat Openshift 1, weak default permissions are applied to the /etc/openshift/server_priv.pem file on the broker server, which could allow users with local access to the broker to read this file.
Northern.tech CFEngine Enterprise 3.15.4 before 3.15.5 has Insecure Permissions that may allow unauthorized local users to have an unspecified impact.
ldap-git-backup before 1.0.4 exposes password hashes due to incorrect directory permissions.
In applySyncTransaction of WindowOrganizer.java, a missing permission check could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-12L Android-13Android ID: A-259938771
Python keyring has insecure permissions on new databases allowing world-readable files to be created
In InputMethodEditor, there is a possible way to access some files accessible to Settings due to an unsafe PendingIntent. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-12LAndroid ID: A-203777141
In getCallStateUsingPackage of Telecom Service, there is a missing permission check. This could lead to local information disclosure of the call state with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-12LAndroid ID: A-190400974
In Framework, there is a possible disclosure of the device owner package due to a missing permission check. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-12LAndroid ID: A-193033501
The Icinga PowerShell Framework provides configuration and check possibilities to ensure integration and monitoring of Windows environments. In versions prior to 1.13.4, 1.12.4, and 1.11.2, permissions of the Icinga for Windows `certificate` directory grant every user read access, which results in the exposure of private key of the Icinga certificate for the given host. All installations are affected. Versions 1.13.4, 1.12.4, and 1.11.2 contains a patch. Please note that upgrading to a fixed version of Icinga for Windows will also automatically fix a similar issue present in Icinga 2, CVE-2026-24413. As a workaround, the permissions can be restricted manually by updating the ACL for the given folder `C:\Program Files\WindowsPowerShell\modules\icinga-powershell-framework\certificate` (and `C:\ProgramData\icinga2\var` to fix the issue for the Icinga 2 agent as well) including every sub-folder and item to restrict access for general users, only allowing the Icinga service user and administrators access.
An exposure of sensitive information vulnerability exists in the Rockwell Automation FactoryTalk® System Service. A malicious user could exploit this vulnerability by starting a back-up or restore process, which temporarily exposes private keys, passwords, pre-shared keys, and database folders when they are temporarily copied to an interim folder. This vulnerability is due to the lack of explicit permissions set on the backup folder. If private keys are obtained by a malicious user, they could impersonate resources on the secured network.
An incorrect permission in the installation directory for the shared NI SystemLink Server KeyValueDatabase service may result in information disclosure via local access. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service.
Permission management vulnerability in the lock screen module Impact: Successful exploitation of this vulnerability may affect service confidentiality.