In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information.
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user.
An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic.
A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file.
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.
A CWE-321: Use of hard-coded cryptographic key stored in cleartext vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker to decrypt a password.
A CWE-316: Cleartext Storage of Sensitive Information in Memory vulnerability exists in Easergy Builder V1.4.7.2 and prior which could allow an attacker access to login credentials.
A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to read user credentials.
A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictable salt would provide.
A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure.
Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4.
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.
Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors.
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause Sensitive data such as login credentials being exposed when a Network is sniffed. Affected Product: Conext� ComBox (All Versions)
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network.
calamares-nixos-extensions provides Calamares branding and modules for NixOS, a distribution of GNU/Linux. Users of calamares-nixos-extensions version 0.3.12 and prior who installed NixOS through the graphical calamares installer, with an unencrypted `/boot`, on either non-UEFI systems or with a LUKS partition different from `/` have their LUKS key file in `/boot` as a plaintext CPIO archive attached to their NixOS initrd. A patch is available and anticipated to be part of version 0.3.13 to backport to NixOS 22.11, 23.05, and unstable channels. Expert users who have a copy of their data may, as a workaround, re-encrypt the LUKS partition(s) themselves.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.
Insufficiently protected credentials in the Intel(R) Team Blue mobile application in all versions may allow an authenticated user to potentially enable information disclosure via local access.
Insufficiently Protected Credentials vulnerability in the remote backups application on Western Digital My Cloud devices that could allow an attacker who has gained access to a relevant endpoint to use that information to access protected data. This issue affects: Western Digital My Cloud My Cloud versions prior to 5.25.124 on Linux.
IBM Common Licensing 9.0 stores user credentials in plain clear text which can be read by a local user.
OpenClaw is a personal AI assistant. Telegram bot tokens can appear in error messages and stack traces (for example, when request URLs include `https://api.telegram.org/bot<token>/...`). Prior to version 2026.2.15, OpenClaw logged these strings without redaction, which could leak the bot token into logs, crash reports, CI output, or support bundles. Disclosure of a Telegram bot token allows an attacker to impersonate the bot and take over Bot API access. Users should upgrade to version 2026.2.15 to obtain a fix and rotate the Telegram bot token if it may have been exposed.
In JetBrains IntelliJ IDEA before 2021.3.3 it was possible to get passwords from protected fields
Lexiglot through 2014-11-20 allows local users to obtain sensitive information by listing a process because the username and password are on the command line.
IBM API Connect V10.0.5.3 and V10.0.6.0 stores user credentials in browser cache which can be read by a local user. IBM X-Force ID: 271912.
Broadcom RAID Controller web interface is vulnerable to exposure of sensitive data and the keys used for encryption are accessible to any local user on Windows
Broadcom RAID Controller web interface is vulnerable to exposure of sensitive data and the keys used for encryption are accessible to any local user on Linux
PingID Windows Login prior to 2.8 does not properly set permissions on the Windows Registry entries used to store sensitive API keys under some circumstances.
An issue was discovered in the C AMQP client library (aka rabbitmq-c) through 0.13.0 for RabbitMQ. Credentials can only be entered on the command line (e.g., for amqp-publish or amqp-consume) and are thus visible to local attackers by listing a process and its arguments.
An issue was discovered in Keeper Password Manager for Desktop version 16.10.2 (fixed in 17.2), and the KeeperFill Browser Extensions version 16.5.4 (fixed in 17.2), allows local attackers to gain sensitive information via plaintext password storage in memory after the user is already logged in, and may persist after logout. NOTE: the vendor disputes this for two reasons: the information is inherently available during a logged-in session when the attacker can read from arbitrary memory locations, and information only remains available after logout because of memory-management limitations of web browsers (not because the Keeper technology itself is retaining the information).
Dell EMC System Update, version 1.9.2 and prior, contain an Unprotected Storage of Credentials vulnerability. A local attacker with user privleges could potentially exploit this vulnerability leading to the disclosure of user passwords.
NCH Express Invoice 7.25 allows local users to discover the cleartext password by reading the configuration file.
Dell DM5500 5.14.0.0, contain a Plain-text Password Storage Vulnerability in the appliance. A local attacker with privileges could potentially exploit this vulnerability, leading to the disclosure of certain service credentials. The attacker may be able to use the exposed credentials to access the vulnerable application with privileges of the compromised account.
Jenkins Metrics Plugin 4.0.2.8 and earlier stores an access key unencrypted in its global configuration file on the Jenkins controller where it can be viewed by users with access to the Jenkins controller file system.
IBM Sterling Secure Proxy and IBM Sterling External Authentication Server 6.0.3 and 6.1.0 stores user credentials in plain clear text which can be read by a local user with container access. IBM X-Force ID: 255585.
A lack of password masking in Devolutions Remote Desktop Manager allows physically proximate attackers to observe sensitive data. A caching issue can cause sensitive fields to sometimes stay revealed when closing and reopening a panel, which could lead to involuntarily disclosing sensitive information. This issue affects: Devolutions Remote Desktop Manager 2022.1.24 version and prior versions.
Ansible before 1.5.5 constructs filenames containing user and password fields on the basis of deb lines in sources.list, which might allow local users to obtain sensitive credential information in opportunistic circumstances by leveraging existence of a file that uses the "deb http://user:pass@server:port/" format.