Junos OS: SRX5000 Series: flowd process crash due to receipt of specific TCP packet
On SRX5000 Series devices, if 'set security zones security-zone <zone> tcp-rst' is configured, the flowd process may crash when a specific TCP packet is received by the device and triggers a new session. The process restarts automatically. However, receipt of a constant stream of these TCP packets may result in an extended Denial of Service (DoS) condition on the device. This issue affects Juniper Networks Junos OS: 18.2R3 on SRX 5000 Series; 18.4R2 on SRX 5000 Series; 19.2R1 on SRX 5000 Series.
Problem Types
Type | CWE ID | Description |
---|
text | N/A | Denial of Service |
Type: text
CWE ID: N/A
Description: Denial of Service
Metrics
Version | Base score | Base severity | Vector |
---|
3.1 | 7.5 | HIGH | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
Version: 3.1
Base score: 7.5
Base severity: HIGH
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H