Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2019-10924

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-14 May, 2019 | 19:54
Updated At-04 Aug, 2024 | 22:40
Rejected At-
Credits

A vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.3). The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated project file. No further privileges are required on the target system. The vulnerability could compromise the confidentiality, integrity and availability of the engineering station. At the time of advisory publication no public exploitation of this security vulnerability was known.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:14 May, 2019 | 19:54
Updated At:04 Aug, 2024 | 22:40
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.3). The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated project file. No further privileges are required on the target system. The vulnerability could compromise the confidentiality, integrity and availability of the engineering station. At the time of advisory publication no public exploitation of this security vulnerability was known.

Affected Products
Vendor
Siemens AGSiemens
Product
LOGO! Soft Comfort
Versions
Affected
  • All versions < V8.3
Problem Types
TypeCWE IDDescription
CWECWE-502CWE-502: Deserialization of Untrusted Data
Type: CWE
CWE ID: CWE-502
Description: CWE-502: Deserialization of Untrusted Data
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.securityfocus.com/bid/108368
vdb-entry
x_refsource_BID
https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf
x_refsource_MISC
Hyperlink: http://www.securityfocus.com/bid/108368
Resource:
vdb-entry
x_refsource_BID
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.securityfocus.com/bid/108368
vdb-entry
x_refsource_BID
x_transferred
https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf
x_refsource_MISC
x_transferred
Hyperlink: http://www.securityfocus.com/bid/108368
Resource:
vdb-entry
x_refsource_BID
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:14 May, 2019 | 20:29
Updated At:04 Jan, 2022 | 18:11

A vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.3). The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated project file. No further privileges are required on the target system. The vulnerability could compromise the confidentiality, integrity and availability of the engineering station. At the time of advisory publication no public exploitation of this security vulnerability was known.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.8HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Primary2.06.8MEDIUM
AV:N/AC:M/Au:N/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 7.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.8
Base severity: MEDIUM
Vector:
AV:N/AC:M/Au:N/C:P/I:P/A:P
CPE Matches

Siemens AG
siemens
>>logo\!_soft_comfort>>Versions before 8.3(exclusive)
cpe:2.3:a:siemens:logo\!_soft_comfort:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-502Primaryproductcert@siemens.com
NVD-CWE-noinfoSecondarynvd@nist.gov
CWE ID: CWE-502
Type: Primary
Source: productcert@siemens.com
CWE ID: NVD-CWE-noinfo
Type: Secondary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://www.securityfocus.com/bid/108368productcert@siemens.com
Third Party Advisory
VDB Entry
https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdfproductcert@siemens.com
Vendor Advisory
Hyperlink: http://www.securityfocus.com/bid/108368
Source: productcert@siemens.com
Resource:
Third Party Advisory
VDB Entry
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

716Records found

CVE-2024-49849
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.4||HIGH
EPSS-0.07% / 22.36%
||
7 Day CHG~0.00%
Published-10 Dec, 2024 | 13:53
Updated-09 Dec, 2025 | 16:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC S7-PLCSIM V17SIMATIC STEP 7 V18SIMATIC STEP 7 Safety V18SIRIUS Soft Starter ES V18 (TIA Portal)SIMATIC STEP 7 V17SIMATIC STEP 7 Safety V16SIMATIC WinCC Unified V18SIMATIC STEP 7 V16SINAMICS Startdrive V16SIRIUS Safety ES V19 (TIA Portal)SIMATIC WinCC Unified V16TIA Portal Cloud V17SIRIUS Soft Starter ES V19 (TIA Portal)TIA Portal Cloud V18SIRIUS Safety ES V18 (TIA Portal)SIMOCODE ES V19TIA Portal Cloud V19SINAMICS Startdrive V19SIMATIC WinCC V18SIMOCODE ES V18SIMATIC WinCC V17SIMATIC WinCC V16SIMATIC WinCC Unified V17SIMATIC STEP 7 Safety V19SIMOTION SCOUT TIA V5.4SINAMICS Startdrive V18SINAMICS Startdrive V17TIA Portal Cloud V16SIMOTION SCOUT TIA V5.6SIMOTION SCOUT TIA V5.5SIRIUS Soft Starter ES V17 (TIA Portal)SIRIUS Safety ES V17 (TIA Portal)SIMATIC STEP 7 V19SIMATIC WinCC Unified V19SIMATIC STEP 7 Safety V17SIMATIC WinCC V19SIMOCODE ES V16SIMATIC S7-PLCSIM V16SIMOCODE ES V17
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2022-45147
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.09% / 26.15%
||
7 Day CHG~0.00%
Published-09 Jul, 2024 | 12:04
Updated-27 Aug, 2025 | 20:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC STEP 7 V17SIMATIC STEP 7 V18SIMATIC STEP 7 V16SIMATIC PCS neo V4.0simatic_pcs_neosimatic_step_7
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2018-7891
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-8.1||HIGH
EPSS-2.68% / 85.51%
||
7 Day CHG~0.00%
Published-30 Apr, 2018 | 15:00
Updated-05 Aug, 2024 | 06:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Milestone XProtect Video Management Software (Corporate, Expert, Professional+, Express+, Essential+) 2016 R1 (10.0.a) to 2018 R1 (12.1a) contains .NET Remoting endpoints that are vulnerable to deserialization attacks resulting in remote code execution.

Action-Not Available
Vendor-milestonesysn/aSiemens AG
Product-siveillance_vmsxprotectn/a
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2025-40759
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.13% / 32.26%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:17
Updated-09 Dec, 2025 | 16:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC S7-PLCSIM V17SIMATIC STEP 7 V18SIRIUS Soft Starter ES V18 (TIA Portal)SIMATIC STEP 7 V17SIMOTION SCOUT TIA V5.7SIMATIC WinCC V20SIRIUS Safety ES V19 (TIA Portal)TIA Portal Cloud V17SIMATIC STEP 7 V20SIRIUS Soft Starter ES V19 (TIA Portal)TIA Portal Cloud V18SIRIUS Safety ES V18 (TIA Portal)SIMOCODE ES V19TIA Portal Cloud V19SINAMICS Startdrive V19SIMATIC WinCC V18SIMOCODE ES V18SIRIUS Safety ES V20 (TIA Portal)SIMATIC WinCC V17SINAMICS Startdrive V20SIMOTION SCOUT TIA V5.4SINAMICS Startdrive V18SINAMICS Startdrive V17SIMOTION SCOUT TIA V5.6SIMOTION SCOUT TIA V5.5SIRIUS Soft Starter ES V17 (TIA Portal)SIRIUS Safety ES V17 (TIA Portal)SIMATIC STEP 7 V19TIA Portal Cloud V20SIMATIC WinCC V19SIMOCODE ES V20SIMOCODE ES V17SIRIUS Soft Starter ES V20 (TIA Portal)
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2015-1049
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.54% / 66.98%
||
7 Day CHG~0.00%
Published-02 Feb, 2015 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The web server on Siemens SCALANCE X-200IRT switches with firmware before 5.2.0 allows remote attackers to hijack sessions via unspecified vectors.

Action-Not Available
Vendor-n/aSiemens AG
Product-scalance_x204irtscalance_x202-2p_irtscalance_x202-2irtscalance_x202-4p_irtscalance_xf204irtscalance_x202-2p_irt_proscalance_x-200_series_firmwarescalance_x204irt_proscalance_x201-3pirtscalance_x201-3p_irt_pron/a
CWE ID-CWE-20
Improper Input Validation
CVE-2022-39138
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:40
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17284)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-39141
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 17.36%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:40
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-17296)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-39149
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:41
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17733)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2018-11455
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-2.66% / 85.45%
||
7 Day CHG~0.00%
Published-07 Aug, 2018 | 15:00
Updated-05 Aug, 2024 | 08:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4), Automation License Manager 6 (All versions < 6.0.1). A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or special conditions of the system, but user interaction is required.

Action-Not Available
Vendor-Siemens AG
Product-automation_license_managerAutomation License Manager 5, Automation License Manager 6
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2015-1597
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-6.8||MEDIUM
EPSS-0.40% / 60.31%
||
7 Day CHG~0.00%
Published-07 Mar, 2015 | 02:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Siemens SPCanywhere application for Android does not use encryption during the loading of code, which allows man-in-the-middle attackers to execute arbitrary code by modifying the client-server data stream.

Action-Not Available
Vendor-n/aSiemens AG
Product-spcanywheren/a
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2022-39157
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.12% / 30.55%
||
7 Day CHG~0.00%
Published-08 Nov, 2022 | 00:00
Updated-21 Apr, 2025 | 13:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 < V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)

Action-Not Available
Vendor-Siemens AG
Product-parasolidParasolid V34.0Parasolid V35.0Parasolid V34.1Simcenter Femap
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-39155
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:41
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-39143
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:40
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17493)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-39139
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:40
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17289)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-39151
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:41
Updated-05 Jun, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17736)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Parasolid V34.1Simcenter Femap V2022.1Parasolid V35.0Parasolid V33.1Simcenter Femap V2022.2
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-39136
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-08 Nov, 2022 | 00:00
Updated-21 Apr, 2025 | 13:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V13.3 (All versions >= V13.3.0.7 < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected application is vulnerable to fixed-length heap-based buffer while parsing specially crafted TIF files. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationTeamcenter Visualization V13.3Teamcenter Visualization V13.2JT2GoTeamcenter Visualization V14.1Teamcenter Visualization V14.0
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-39152
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:41
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-47940
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.13% / 32.55%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:49
Updated-13 Nov, 2024 | 23:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2024Solid Edge SE2024solid_edge_se2024
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-39154
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:41
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-39147
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:41
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted X_T files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-17506)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-824
Access of Uninitialized Pointer
CVE-2022-39145
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:41
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17496)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-39150
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:41
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17735)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-39144
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-13 Sep, 2022 | 09:41
Updated-03 Aug, 2024 | 11:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17494)

Action-Not Available
Vendor-Siemens AG
Product-parasolidsimcenter_femapParasolid V34.0Simcenter Femap V2022.1Parasolid V35.0Simcenter Femap V2022.2Parasolid V33.1Parasolid V34.1
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-37864
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.06% / 19.38%
||
7 Day CHG~0.00%
Published-11 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge (All Versions < SE2022MP9). The affected application contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17627)

Action-Not Available
Vendor-Siemens AG
Product-solid_edgeSolid Edge
CWE ID-CWE-122
Heap-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-45470
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.11% / 29.38%
||
7 Day CHG-0.02%
Published-08 Oct, 2024 | 08:40
Updated-10 Dec, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTeamcenter Visualization V2312Tecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3tecnomatix_plant_simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-45474
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.10% / 28.51%
||
7 Day CHG-0.02%
Published-08 Oct, 2024 | 08:40
Updated-10 Dec, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. An attacker could leverage this in conjunction with other vulnerabilities to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTeamcenter Visualization V2312Tecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3tecnomatix_plant_simulation
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-45464
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.14% / 34.49%
||
7 Day CHG-0.02%
Published-08 Oct, 2024 | 08:40
Updated-10 Dec, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTeamcenter Visualization V2312Tecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3tecnomatix_plant_simulation
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-45469
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.14% / 34.48%
||
7 Day CHG-0.02%
Published-08 Oct, 2024 | 08:40
Updated-10 Dec, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTeamcenter Visualization V2312Tecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3tecnomatix_plant_simulation
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-41908
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.19% / 40.70%
||
7 Day CHG~0.00%
Published-13 Aug, 2024 | 07:54
Updated-13 Aug, 2024 | 13:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in NX (All versions < V2406.3000). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-NXnx_1988_firmware
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-41902
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.07% / 21.98%
||
7 Day CHG-0.01%
Published-08 Oct, 2024 | 08:40
Updated-23 Oct, 2024 | 14:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-jt2goJT2Gojt2go
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-47941
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.13% / 32.55%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:49
Updated-13 Nov, 2024 | 23:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-solid_edge_se2024Solid Edge SE2024solid_edge_se2024
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-47046
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.09% / 25.56%
||
7 Day CHG-0.02%
Published-08 Oct, 2024 | 08:40
Updated-15 Oct, 2025 | 17:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The affected application is vulnerable to memory corruption while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_nastranSimcenter Femap V2401Simcenter Femap V2406Simcenter Femap V2306simcenter_nastran
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-41981
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.04% / 10.57%
||
7 Day CHG-0.01%
Published-08 Oct, 2024 | 08:40
Updated-10 Dec, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-Simcenter Femap V2401Simcenter Femap V2406Simcenter Femap V2306simcenter_nastran
CWE ID-CWE-122
Heap-based Buffer Overflow
CVE-2023-30900
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.10% / 26.60%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Xpedition Layout Browser (All versions < VX.2.14). Affected application contains a stack overflow vulnerability when parsing a PCB file. An attacker can leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-xpedition_layout_browserXpedition Layout Browser
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2022-34289
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:07
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-054)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-34280
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:07
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-045)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-34275
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-040)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-34286
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:07
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-051)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-34276
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-041)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-34748
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:07
Updated-03 Aug, 2024 | 09:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2022.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17293)

Action-Not Available
Vendor-Siemens AG
Product-simcenter_femapSimcenter Femap
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-34278
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-043)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-34284
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:07
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-049)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-34281
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:07
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-046)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-34274
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-039)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-34272
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.8||HIGH
EPSS-0.42% / 61.30%
||
7 Day CHG~0.00%
Published-12 Jul, 2022 | 10:06
Updated-03 Aug, 2024 | 09:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-037, FG-VD-22-059)

Action-Not Available
Vendor-Siemens AG
Product-pads_viewerPADS Standard/Plus Viewer
CWE ID-CWE-125
Out-of-bounds Read
CVE-2026-23717
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.01% / 0.23%
||
7 Day CHG~0.00%
Published-10 Feb, 2026 | 09:58
Updated-11 Feb, 2026 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_nastransimcenter_femapSimcenter NastranSimcenter Femap
CWE ID-CWE-125
Out-of-bounds Read
CVE-2026-23716
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.01% / 0.23%
||
7 Day CHG~0.00%
Published-10 Feb, 2026 | 09:58
Updated-11 Feb, 2026 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-simcenter_nastransimcenter_femapSimcenter NastranSimcenter Femap
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-45472
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.10% / 28.51%
||
7 Day CHG-0.02%
Published-08 Oct, 2024 | 08:40
Updated-10 Dec, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. An attacker could leverage this in conjunction with other vulnerabilities to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTeamcenter Visualization V2312Tecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3tecnomatix_plant_simulation
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2024-45466
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.14% / 34.49%
||
7 Day CHG-0.02%
Published-08 Oct, 2024 | 08:40
Updated-10 Dec, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTeamcenter Visualization V2312Tecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3tecnomatix_plant_simulation
CWE ID-CWE-125
Out-of-bounds Read
CVE-2024-45465
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.14% / 34.49%
||
7 Day CHG-0.02%
Published-08 Oct, 2024 | 08:40
Updated-10 Dec, 2024 | 14:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

Action-Not Available
Vendor-Siemens AG
Product-tecnomatix_plant_simulationTeamcenter Visualization V2312Tecnomatix Plant Simulation V2302Teamcenter Visualization V14.2Tecnomatix Plant Simulation V2404Teamcenter Visualization V14.3tecnomatix_plant_simulation
CWE ID-CWE-125
Out-of-bounds Read
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 14
  • 15
  • Next
Details not found