Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2019-11073

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-16 Mar, 2020 | 18:41
Updated At-04 Aug, 2024 | 22:40
Rejected At-
Credits

A Remote Code Execution vulnerability exists in PRTG Network Monitor before 19.4.54.1506 that allows attackers to execute code due to insufficient sanitization when passing arguments to the HttpTransactionSensor.exe binary. In order to exploit the vulnerability, remote authenticated administrators need to create a new HTTP Transaction Sensor and set specific settings when the sensor is executed.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:16 Mar, 2020 | 18:41
Updated At:04 Aug, 2024 | 22:40
Rejected At:
▼CVE Numbering Authority (CNA)

A Remote Code Execution vulnerability exists in PRTG Network Monitor before 19.4.54.1506 that allows attackers to execute code due to insufficient sanitization when passing arguments to the HttpTransactionSensor.exe binary. In order to exploit the vulnerability, remote authenticated administrators need to create a new HTTP Transaction Sensor and set specific settings when the sensor is executed.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.paessler.com/prtg/history/stable
x_refsource_MISC
https://sensepost.com/blog/2019/being-stubborn-pays-off-pt.-1-cve-2018-19204/
x_refsource_MISC
https://www.bsi.bund.de/SharedDocs/Warnmeldungen/DE/CB/2019/11/warnmeldung_cb-k19-1019.html
x_refsource_MISC
Hyperlink: https://www.paessler.com/prtg/history/stable
Resource:
x_refsource_MISC
Hyperlink: https://sensepost.com/blog/2019/being-stubborn-pays-off-pt.-1-cve-2018-19204/
Resource:
x_refsource_MISC
Hyperlink: https://www.bsi.bund.de/SharedDocs/Warnmeldungen/DE/CB/2019/11/warnmeldung_cb-k19-1019.html
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.paessler.com/prtg/history/stable
x_refsource_MISC
x_transferred
https://sensepost.com/blog/2019/being-stubborn-pays-off-pt.-1-cve-2018-19204/
x_refsource_MISC
x_transferred
https://www.bsi.bund.de/SharedDocs/Warnmeldungen/DE/CB/2019/11/warnmeldung_cb-k19-1019.html
x_refsource_MISC
x_transferred
Hyperlink: https://www.paessler.com/prtg/history/stable
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://sensepost.com/blog/2019/being-stubborn-pays-off-pt.-1-cve-2018-19204/
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://www.bsi.bund.de/SharedDocs/Warnmeldungen/DE/CB/2019/11/warnmeldung_cb-k19-1019.html
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:16 Mar, 2020 | 19:15
Updated At:24 Aug, 2020 | 17:37

A Remote Code Execution vulnerability exists in PRTG Network Monitor before 19.4.54.1506 that allows attackers to execute code due to insufficient sanitization when passing arguments to the HttpTransactionSensor.exe binary. In order to exploit the vulnerability, remote authenticated administrators need to create a new HTTP Transaction Sensor and set specific settings when the sensor is executed.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.17.2HIGH
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Primary
Version: 3.1
Base score: 7.2
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

paessler
paessler
>>prtg_network_monitor>>Versions before 19.4.54.1506(exclusive)
cpe:2.3:a:paessler:prtg_network_monitor:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-74Primarynvd@nist.gov
CWE ID: CWE-74
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://sensepost.com/blog/2019/being-stubborn-pays-off-pt.-1-cve-2018-19204/cve@mitre.org
Exploit
Third Party Advisory
https://www.bsi.bund.de/SharedDocs/Warnmeldungen/DE/CB/2019/11/warnmeldung_cb-k19-1019.htmlcve@mitre.org
Third Party Advisory
https://www.paessler.com/prtg/history/stablecve@mitre.org
Release Notes
Hyperlink: https://sensepost.com/blog/2019/being-stubborn-pays-off-pt.-1-cve-2018-19204/
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory
Hyperlink: https://www.bsi.bund.de/SharedDocs/Warnmeldungen/DE/CB/2019/11/warnmeldung_cb-k19-1019.html
Source: cve@mitre.org
Resource:
Third Party Advisory
Hyperlink: https://www.paessler.com/prtg/history/stable
Source: cve@mitre.org
Resource:
Release Notes

Change History

0
Information is not available yet

Similar CVEs

129Records found

CVE-2023-32782
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-21.93% / 95.55%
||
7 Day CHG~0.00%
Published-09 Aug, 2023 | 00:00
Updated-10 Oct, 2024 | 16:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection was identified in PRTG 23.2.84.1566 and earlier versions in the Dicom C-ECHO sensor where an authenticated user with write permissions could abuse the debug option to write new files that could potentially get executed by the EXE/Script sensor. The severity of this vulnerability is high and received a score of 7.2 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Action-Not Available
Vendor-paesslern/a
Product-prtg_network_monitorn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-32781
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-42.23% / 97.35%
||
7 Day CHG+6.42%
Published-09 Aug, 2023 | 00:00
Updated-02 Aug, 2024 | 15:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability was identified in PRTG 23.2.84.1566 and earlier versions in the HL7 sensor where an authenticated user with write permissions could abuse the debug option to write new files that could potentially get executed by the EXE/Script sensor. The severity of this vulnerability is high and received a score of 7.2 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Action-Not Available
Vendor-paesslern/a
Product-prtg_network_monitorn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-11074
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-4.96% / 89.26%
||
7 Day CHG~0.00%
Published-17 Mar, 2020 | 14:06
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Write to Arbitrary Location in Disk vulnerability exists in PRTG Network Monitor 19.1.49 and below that allows attackers to place files in arbitrary locations with SYSTEM privileges (although not controlling the contents of such files) due to insufficient sanitisation when passing arguments to the phantomjs.exe binary. In order to exploit the vulnerability, remote authenticated administrators need to create a new HTTP Full Web Page Sensor and set specific settings when executing the sensor.

Action-Not Available
Vendor-paesslern/a
Product-prtg_network_monitorn/a
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2018-9276
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-83.84% / 99.25%
||
7 Day CHG~0.00%
Published-02 Jul, 2018 | 16:00
Updated-30 Jul, 2025 | 01:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2025-02-25||Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

An issue was discovered in PRTG Network Monitor before 18.2.39. An attacker who has access to the PRTG System Administrator web console with administrative privileges can exploit an OS command injection vulnerability (both on the server and on devices) by sending malformed parameters in sensor or notification management scenarios.

Action-Not Available
Vendor-paesslern/aPaessler
Product-prtg_network_monitorn/aPRTG Network Monitor
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-19204
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.03% / 86.12%
||
7 Day CHG-0.06%
Published-12 Nov, 2018 | 16:00
Updated-16 Sep, 2024 | 23:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

PRTG Network Monitor before 18.3.44.2054 allows a remote authenticated attacker (with read-write privileges) to execute arbitrary code and OS commands with system privileges. When creating an HTTP Advanced Sensor, the user's input in the POST parameter 'proxyport_' is mishandled. The attacker can craft an HTTP request and override the 'writeresult' command-line parameter for HttpAdvancedSensor.exe to store arbitrary data in an arbitrary place on the file system. For example, the attacker can create an executable file in the \Custom Sensors\EXE directory and execute it by creating EXE/Script Sensor.

Action-Not Available
Vendor-paesslern/a
Product-prtg_network_monitorn/a
CWE ID-CWE-20
Improper Input Validation
CVE-2024-39784
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-0.34% / 55.87%
||
7 Day CHG+0.16%
Published-14 Jan, 2025 | 14:20
Updated-22 Aug, 2025 | 14:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple command execution vulnerabilities exist in the nas.cgi add_dir() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists in the disk_part POST parameter.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8wl-wn533a8_firmwareWavlink AC3000
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-39785
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-0.34% / 55.87%
||
7 Day CHG+0.16%
Published-14 Jan, 2025 | 14:20
Updated-22 Aug, 2025 | 14:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple command execution vulnerabilities exist in the nas.cgi add_dir() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists in the adddir_name POST parameter.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8wl-wn533a8_firmwareWavlink AC3000
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-36295
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-0.99% / 75.95%
||
7 Day CHG+0.78%
Published-14 Jan, 2025 | 14:21
Updated-21 Aug, 2025 | 20:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command execution vulnerability exists in the qos.cgi qos_sta() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-41111
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.2||HIGH
EPSS-0.09% / 26.25%
||
7 Day CHG-0.21%
Published-18 Jul, 2024 | 22:11
Updated-02 Aug, 2024 | 04:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
BishopFox Sliver Authenticated Remote Code Execution

Sliver is an open source cross-platform adversary emulation/red team framework, it can be used by organizations of all sizes to perform security testing. Sliver version 1.6.0 (prerelease) is vulnerable to RCE on the teamserver by a low-privileged "operator" user. The RCE is as the system root user. The exploit is pretty fun as we make the Sliver server pwn itself. As described in a past issue (#65), "there is a clear security boundary between the operator and server, an operator should not inherently be able to run commands or code on the server." An operator who exploited this vulnerability would be able to view all console logs, kick all other operators, view and modify files stored on the server, and ultimately delete the server. This issue has not yet be addressed but is expected to be resolved before the full release of version 1.6.0. Users of the 1.6.0 prerelease should avoid using Silver in production.

Action-Not Available
Vendor-BishopFoxbishopfox
Product-sliversliver
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2023-22621
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-86.74% / 99.38%
||
7 Day CHG~0.00%
Published-19 Apr, 2023 | 00:00
Updated-05 Feb, 2025 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Strapi through 4.5.5 allows authenticated Server-Side Template Injection (SSTI) that can be exploited to execute arbitrary code on the server. A remote attacker with access to the Strapi admin panel can inject a crafted payload that executes code on the server into an email template that bypasses the validation checks that should prevent code execution.

Action-Not Available
Vendor-n/aStrapi, Inc.
Product-strapin/a
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2023-20858
Matching Score-4
Assigner-VMware by Broadcom
ShareView Details
Matching Score-4
Assigner-VMware by Broadcom
CVSS Score-7.2||HIGH
EPSS-4.66% / 88.89%
||
7 Day CHG~0.00%
Published-21 Feb, 2023 | 00:00
Updated-17 Mar, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VMware Carbon Black App Control 8.7.x prior to 8.7.8, 8.8.x prior to 8.8.6, and 8.9.x.prior to 8.9.4 contain an injection vulnerability. A malicious actor with privileged access to the App Control administration console may be able to use specially crafted input allowing access to the underlying server operating system.

Action-Not Available
Vendor-n/aVMware (Broadcom Inc.)Microsoft Corporation
Product-carbon_black_app_controlwindowsVMware Carbon Black App Control
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-16875
Matching Score-4
Assigner-Microsoft Corporation
ShareView Details
Matching Score-4
Assigner-Microsoft Corporation
CVSS Score-8.4||HIGH
EPSS-88.70% / 99.49%
||
7 Day CHG~0.00%
Published-11 Sep, 2020 | 17:08
Updated-04 Aug, 2024 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Microsoft Exchange Server Remote Code Execution Vulnerability

<p>A remote code execution vulnerability exists in Microsoft Exchange server due to improper validation of cmdlet arguments.</p> <p>An attacker who successfully exploited the vulnerability could run arbitrary code in the context of the System user. Exploitation of the vulnerability requires an authenticated user in a certain Exchange role to be compromised.</p> <p>The security update addresses the vulnerability by correcting how Microsoft Exchange handles cmdlet arguments.</p>

Action-Not Available
Vendor-Microsoft Corporation
Product-exchange_serverMicrosoft Exchange Server 2019 Cumulative Update 5Microsoft Exchange Server 2019 Cumulative Update 6Microsoft Exchange Server 2016 Cumulative Update 16Microsoft Exchange Server 2016 Cumulative Update 17
CWE ID-CWE-269
Improper Privilege Management
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-15244
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8||HIGH
EPSS-0.87% / 74.27%
||
7 Day CHG~0.00%
Published-21 Oct, 2020 | 20:05
Updated-04 Aug, 2024 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
RCE in Magento

In Magento (rubygems openmage/magento-lts package) before versions 19.4.8 and 20.0.4, an admin user can generate soap credentials that can be used to trigger RCE via PHP Object Injection through product attributes and a product. The issue is patched in versions 19.4.8 and 20.0.4.

Action-Not Available
Vendor-openmageOpenMage
Product-magentomagento-lts
CWE ID-CWE-502
Deserialization of Untrusted Data
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2022-20693
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-4.7||MEDIUM
EPSS-1.42% / 79.77%
||
7 Day CHG~0.00%
Published-15 Apr, 2022 | 14:16
Updated-06 Nov, 2024 | 16:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco IOS XE Software Web UI API Injection Vulnerability

A vulnerability in the web UI feature of Cisco IOS XE Software could allow an authenticated, remote attacker to perform an injection attack against an affected device. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI API. A successful exploit could allow the attacker to inject commands to the underlying operating system with root privileges.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ios_xeCisco IOS XE Software
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-15252
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.5||HIGH
EPSS-2.70% / 85.30%
||
7 Day CHG~0.00%
Published-16 Oct, 2020 | 16:55
Updated-04 Aug, 2024 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
RCE in XWiki

In XWiki before version 12.5 and 11.10.6, any user with SCRIPT right (EDIT right before XWiki 7.4) can gain access to the application server Servlet context which contains tools allowing to instantiate arbitrary Java objects and invoke methods that may lead to arbitrary code execution. This is patched in XWiki 12.5 and XWiki 11.10.6.

Action-Not Available
Vendor-XWiki SAS
Product-xwikixwiki-platform
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-14987
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-6.88% / 91.00%
||
7 Day CHG~0.00%
Published-11 Mar, 2021 | 17:50
Updated-04 Aug, 2024 | 13:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Bloomreach Experience Manager (brXM) 4.1.0 through 14.2.2. It allows remote attackers to execute arbitrary code because there is a mishandling of the capability for administrators to write and run Groovy scripts within the updater editor. An attacker must use an AST transforming annotation such as @Grab.

Action-Not Available
Vendor-bloomreachn/a
Product-experience_managern/a
CWE ID-CWE-862
Missing Authorization
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2022-43769
Matching Score-4
Assigner-Hitachi Vantara
ShareView Details
Matching Score-4
Assigner-Hitachi Vantara
CVSS Score-8.8||HIGH
EPSS-93.93% / 99.87%
||
7 Day CHG~0.00%
Published-03 Apr, 2023 | 17:47
Updated-30 Jul, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Known KEV||Action Due Date - 2025-03-24||Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
Hitachi Vantara Pentaho Business Analytics Server - Failure to Sanitize Special Elements into a Different Plane (Special Element Injection)

Hitachi Vantara Pentaho Business Analytics Server prior to versions 9.4.0.1 and 9.3.0.2, including 8.3.x allow certain web services to set property values which contain Spring templates that are interpreted downstream.

Action-Not Available
Vendor-Hitachi, Ltd.Hitachi Vantara LLC
Product-vantara_pentaho_business_analytics_serverPentaho Business Analytics ServerPentaho Business Analytics (BA) Server
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2025-8158
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 6.66%
||
7 Day CHG~0.00%
Published-25 Jul, 2025 | 13:32
Updated-29 Jul, 2025 | 17:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
PHPGurukul Login and User Management System yesterday-reg-users.php sql injection

A vulnerability was found in PHPGurukul Login and User Management System 3.3. It has been declared as critical. This vulnerability affects unknown code of the file /admin/yesterday-reg-users.php. The manipulation of the argument ID leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-PHPGurukul LLP
Product-user_registration_\&_login_and_user_management_systemLogin and User Management System
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2022-41878
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-7.2||HIGH
EPSS-0.06% / 17.07%
||
7 Day CHG~0.00%
Published-10 Nov, 2022 | 00:00
Updated-23 Apr, 2025 | 16:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Parse Server Prototype pollution and Injection via Cloud Code Webhooks or Cloud Code Triggers

Parse Server is an open source backend that can be deployed to any infrastructure that can run Node.js. In versions prior to 5.3.2 or 4.10.19, keywords that are specified in the Parse Server option `requestKeywordDenylist` can be injected via Cloud Code Webhooks or Triggers. This will result in the keyword being saved to the database, bypassing the `requestKeywordDenylist` option. This issue is fixed in versions 4.10.19, and 5.3.2. If upgrade is not possible, the following Workarounds may be applied: Configure your firewall to only allow trusted servers to make request to the Parse Server Cloud Code Webhooks API, or block the API completely if you are not using the feature.

Action-Not Available
Vendor-parseplatformparse-community
Product-parse-serverparse-server
CWE ID-CWE-1321
Improperly Controlled Modification of Object Prototype Attributes ('Prototype Pollution')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2016-5685
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-8.8||HIGH
EPSS-0.61% / 68.86%
||
7 Day CHG~0.00%
Published-29 Nov, 2016 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell iDRAC7 and iDRAC8 devices with firmware before 2.40.40.40 allow authenticated users to gain Bash shell access through a string injection.

Action-Not Available
Vendor-Dell Inc.
Product-idrac8_firmwareidrac7idrac7_firmwareidrac8iDRAC7 and iDRAC8
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2022-37108
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.7||HIGH
EPSS-0.29% / 51.45%
||
7 Day CHG~0.00%
Published-07 Sep, 2022 | 13:06
Updated-03 Aug, 2024 | 10:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An injection vulnerability in the syslog-ng configuration wizard in Securonix Snypr 6.4 allows an application user with the "Manage Ingesters" permission to execute arbitrary code on remote ingesters by appending arbitrary text to text files that are executed by the system, such as users' crontab files. The patch for this was present in SNYPR version 6.4 Jun 2022 R3_[06170871], but may have been introduced sooner.

Action-Not Available
Vendor-securonixn/a
Product-snyprn/a
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2022-36323
Matching Score-4
Assigner-Siemens
ShareView Details
Matching Score-4
Assigner-Siemens
CVSS Score-9.1||CRITICAL
EPSS-0.31% / 53.93%
||
7 Day CHG+0.04%
Published-10 Aug, 2022 | 11:18
Updated-20 May, 2025 | 19:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.

Action-Not Available
Vendor-Siemens AG
Product-scalance_xc208scalance_xb205-3scalance_xc216eec_firmwarescalance_xr552_firmwarescalance_xr324-4m_eecscalance_sc-600_firmwarescalance_xp-200scalance_xp208scalance_xc206-2sfp_g_\(e\/ip\)scalance_xc224-4c_g_eec_firmwarescalance_xr324-4m_eec_firmwarescalance_xr-300eec_firmwarescalance_xf-200bascalance_xc206-2sfp_g_eec_firmwarescalance_xp216scalance_xb213-3_firmwarescalance_xr528-6m_2hr2_firmwarescalance_xr-300_firmwarescalance_xb205-3ldscalance_xc208g_eecscalance_sc622-2c_firmwarescalance_s615_firmwarescalance_xr528-6m_2hr2scalance_xc206-2sfp_g_firmwarescalance_xr326-2c_poe_wg_firmwarescalance_xr528-6m_firmwarescalance_xr552-12m_2hr2_l3scalance_m-800_firmwarescalance_xb205-3_firmwarescalance_xc216-4c_g_\(e\/ip\)_firmwarescalance_xp216poe_eec_firmwarescalance_xb216_firmwarescalance_w700_ieee_802.11ax_firmwarescalance_xb213-3ldscalance_xc-200_firmwarescalance_xf204-2ba_irtscalance_xr324-12m_tsscalance_xc206-2g_poe__firmwarescalance_xr-300wg_firmwarescalance_xc208g_eec_firmwarescalance_sc642-2c_firmwarescalance_xr-300scalance_xm408-8c_l3_firmwarescalance_sc642-2cscalance_sc-600scalance_xr324-4m_poe_ts_firmwarescalance_xr524scalance_xc208eec_firmwarescalance_xm400scalance_xc208g_poescalance_xc224-4c_g_\(e\/ip\)_firmwarescalance_xm408-8cscalance_xf-200ba_firmwarescalance_xb213-3ld_firmwarescalance_xf204-2ba_irt_firmwarescalance_w700_ieee_802.11acscalance_xc216scalance_xr324-12m_ts_firmwarescalance_xc206-2sfp_g_eecscalance_s615scalance_sc646-2cscalance_xr526-8c_l3scalance_xc206-2sfp_g_\(e\/ip\)_firmwarescalance_xp216eec_firmwarescalance_xm408-8c_l3scalance_xc208g_\(e\/ip\)_firmwarescalance_xp208eecscalance_xr526-8c_l3_firmwarescalance_xm408-8c_firmwarescalance_xb208scalance_xr-300poe_firmwarescalance_xr324-4m_poescalance_xc206-2g_poe_eecscalance_xc216-4c_g_firmwarescalance_xc206-2g_poe_scalance_xr524-8c_firmwarescalance_w700_ieee_802.11axscalance_xc224__firmwarescalance_xb-200_firmwarescalance_xc-200scalance_xr324-4m_poe_tsscalance_xc206-2sfp_gscalance_m-800scalance_xm408-4c_l3scalance_xp208poe_eecscalance_sc636-2c_firmwarescalance_w700_ieee_802.11ac_firmwarescalance_xr526scalance_xf204-2ba_dnascalance_xr552-12m_2hr2_firmwarescalance_xr324-12mscalance_xc206-2_firmwarescalance_xb213-3scalance_xr552scalance_xr528-6mscalance_xc224-4c_g_scalance_xc216-4c_firmwarescalance_xp216poe_eecscalance_xr-300wgscalance_xc216-4c_g_\(e\/ip\)scalance_xm400_firmwarescalance_xb205-3ld_firmwarescalance_xr524_firmwarescalance_xc224-4c_g_eecscalance_w700_ieee_802.11n_firmwarescalance_xc224_scalance_xp216_\(eip\)_firmwarescalance_xm416-4c_firmwarescalance_xc216eecscalance_xr524-8cscalance_xr528-6m_2hr2_l3scalance_xp208_\(eip\)scalance_xr328-4c_wgscalance_xc208gscalance_xb216scalance_xr324wgscalance_xr552-12m_firmwarescalance_xm408-4cscalance_xr552-12mscalance_xc206-2g_poe_eec_firmwarescalance_xc216_firmwarescalance_xc208eecscalance_xc206-2sfp_eec_firmwarescalance_xr328-4c_wg_firmwarescalance_xr526_firmwarescalance_xc216-4cscalance_xr524-8c_l3scalance_xr500_firmwarescalance_xr552-12m_2hr2scalance_xc208g_firmwarescalance_sc632-2cscalance_xc208_firmwarescalance_xp216_\(eip\)scalance_xp208_\(eip\)_firmwarescalance_xp208eec_firmwarescalance_sc646-2c_firmwarescalance_xr524-8c_l3_firmwarescalance_xr324-4m_poe_firmwarescalance_xm408-4c_firmwarescalance_xm416-4cscalance_xr528_firmwarescalance_xr528scalance_xr552-12m_2hr2_l3_firmwarescalance_xr326-2c_poe_wgscalance_sc622-2cscalance_xm408-4c_l3_firmwarescalance_xc208g_\(e\/ip\)scalance_xr324wg_firmwarescalance_xb208_firmwarescalance_xc224-4c_g__firmwarescalance_sc632-2c_firmwarescalance_w700_ieee_802.11nscalance_xc206-2scalance_xc208g_poe_firmwarescalance_xr528-6m_2hr2_l3_firmwarescalance_xr528-6m_l3scalance_xr324-12m_firmwarescalance_xr-300poescalance_xm416-4c_l3scalance_xf204-2ba_dna_firmwarescalance_xp-200_firmwarescalance_xc224-4c_g_\(e\/ip\)scalance_xb-200scalance_sc636-2cscalance_xc216-4c_g_eec_firmwarescalance_xr500scalance_xr552-12scalance_xp216_firmwarescalance_xm416-4c_l3_firmwarescalance_xp208_firmwarescalance_xp208poe_eec_firmwarescalance_xr526-8c_firmwarescalance_xp216eecscalance_xr552-12_firmwarescalance_xc216-4c_g_eecscalance_xc206-2sfp_eecscalance_xc216-4c_gscalance_xr-300eecscalance_xr526-8cscalance_xr528-6m_l3_firmwareSCALANCE XR526-8C, 24V (L3 int.)SCALANCE XC206-2 (SC)SCALANCE XF204-2BA DNASCALANCE XP216EECSCALANCE M876-3 (ROK)SIPLUS NET SCALANCE XC206-2SCALANCE XC206-2G PoE EEC (54 V DC)SCALANCE XR524-8C, 1x230V (L3 int.)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE W788-2 RJ45SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)SCALANCE XM416-4C (L3 int.)RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE W748-1 M12SCALANCE WUM766-1 (US)SCALANCE XR524-8C, 24V (L3 int.)SCALANCE XC208G (EIP def.)SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)SCALANCE XC206-2SFP G (EIP DEF.)SIPLUS NET SCALANCE XC216-4CSCALANCE W738-1 M12SCALANCE XP216 (Ethernet/IP)SCALANCE SC622-2CSCALANCE XC208EECSCALANCE XR526-8C, 2x230V (L3 int.)SCALANCE XR326-2C PoE WG (without UL)SCALANCE W786-2 RJ45SCALANCE XR528-6M (L3 int.)SCALANCE XB205-3 (ST, PN)SCALANCE W778-1 M12 EECSCALANCE XR528-6MSCALANCE XC216-4C GSCALANCE XC216-4C G (EIP Def.)SCALANCE XR528-6M (2HR2, L3 int.)SCALANCE XC216EECSCALANCE SC626-2CSCALANCE WAM766-1 (EU)SCALANCE XR324WG (24 X FE, DC 24V)SCALANCE XF204-2BASCALANCE WAM766-1 EEC (US)SCALANCE XC216-4C G EECSCALANCE M876-4 (NAM)SCALANCE XR328-4C WG (28xGE, DC 24V)SCALANCE M874-3SCALANCE XM408-4CSCALANCE XR552-12M (2HR2, L3 int.)SCALANCE W1748-1 M12SCALANCE XR524-8C, 2x230V (L3 int.)SCALANCE XC224-4C G EECSCALANCE XC224-4C G (EIP Def.)SCALANCE M876-4 (EU)SCALANCE XM408-8C (L3 int.)SCALANCE M876-3 (EVDO)SCALANCE XB208 (E/IP)SCALANCE W774-1 RJ45SCALANCE W788-1 M12SCALANCE XB205-3LD (SC, E/IP)SCALANCE XC208SCALANCE XR526-8C, 1x230V (L3 int.)SCALANCE SC636-2CSCALANCE XC224SCALANCE XP216SCALANCE XR526-8C, 1x230VSCALANCE XB216 (E/IP)SCALANCE XR328-4C WG (28xGE, AC 230V)SCALANCE XR552-12MSCALANCE WAM766-1 EEC (EU)SCALANCE W722-1 RJ45SCALANCE WUM766-1 (EU)SCALANCE M874-2SCALANCE XB205-3 (SC, PN)SCALANCE XB208 (PN)SCALANCE XP208 (Ethernet/IP)SCALANCE M816-1 ADSL-Router (Annex B)SCALANCE XF204SCALANCE XR526-8C, 2x230VSCALANCE W1788-2 EEC M12SCALANCE XB213-3LD (SC, PN)SCALANCE WAM766-1 (US)SCALANCE XP216POE EECSCALANCE XC216-3G PoE (54 V DC)SCALANCE XC206-2 (ST/BFOC)SCALANCE XC208G PoE (54 V DC)SCALANCE XR528-6M (2HR2)SCALANCE XB213-3 (SC, E/IP)SCALANCE MUM856-1 (EU)SCALANCE XC206-2SFPSCALANCE XR552-12M (2HR2)SCALANCE XB213-3 (ST, E/IP)SCALANCE W786-2IA RJ45SCALANCE XR524-8C, 2x230VSCALANCE W734-1 RJ45 (USA)SCALANCE XC208GSCALANCE SC642-2CSCALANCE XC216-4CSCALANCE XC216-3G PoESCALANCE W788-2 M12 EECSCALANCE XR326-2C PoE WGSIPLUS NET SCALANCE XC206-2SFPSCALANCE WAM763-1SCALANCE W761-1 RJ45SCALANCE XF204 DNASCALANCE XC216SCALANCE W788-2 M12SCALANCE W774-1 RJ45 (USA)SCALANCE XB213-3 (ST, PN)SCALANCE XR524-8C, 24VSCALANCE SC646-2CSCALANCE MUM856-1 (RoW)SCALANCE W1788-2IA M12SCALANCE XC208G EECSCALANCE XR324WG (24 x FE, AC 230V)SCALANCE W788-1 RJ45SCALANCE XM408-4C (L3 int.)SCALANCE M812-1 ADSL-Router (Annex A)SCALANCE XR526-8C, 24VSCALANCE W1788-2 M12SCALANCE XC206-2SFP G EECSCALANCE XB205-3 (ST, E/IP)SCALANCE XB213-3 (SC, PN)SCALANCE XC206-2G PoESCALANCE XM416-4CSCALANCE W786-2 SFPSCALANCE XR524-8C, 1x230VSCALANCE W1788-1 M12SCALANCE W774-1 M12 EECSCALANCE XC206-2SFP EECSCALANCE XM408-8CSCALANCE M826-2 SHDSL-RouterSCALANCE M812-1 ADSL-Router (Annex B)SCALANCE XC206-2G PoE (54 V DC)SCALANCE XC206-2SFP GSCALANCE XB216 (PN)SCALANCE XP208PoE EECSCALANCE MUM853-1 (EU)SCALANCE XB213-3LD (SC, E/IP)SCALANCE WUM763-1SIPLUS NET SCALANCE XC208SCALANCE SC632-2CSCALANCE XP208EECSCALANCE W734-1 RJ45SCALANCE W748-1 RJ45SCALANCE M804PBSCALANCE W778-1 M12SCALANCE W721-1 RJ45SCALANCE XC224-4C GSCALANCE XB205-3LD (SC, PN)SCALANCE M816-1 ADSL-Router (Annex A)SCALANCE XP208SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)SCALANCE W778-1 M12 EEC (USA)SCALANCE S615SCALANCE W786-1 RJ45SCALANCE XC208G PoE
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-21797
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-9.1||CRITICAL
EPSS-0.99% / 75.95%
||
7 Day CHG+0.71%
Published-14 Jan, 2025 | 14:21
Updated-21 Aug, 2025 | 18:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command execution vulnerability exists in the adm.cgi set_TR069() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn533a8_firmwarewl-wn533a8Wavlink AC3000
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-20429
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-6.5||MEDIUM
EPSS-0.09% / 26.14%
||
7 Day CHG+0.04%
Published-17 Jul, 2024 | 16:29
Updated-08 Aug, 2025 | 01:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the web-based management interface of Cisco AsyncOS for Secure Email Gateway could allow an authenticated, remote attacker to execute arbitrary system commands on an affected device. This vulnerability is due to insufficient input validation in certain portions of the web-based management interface. An attacker could exploit this vulnerability by sending a crafted HTTP request to the affected device. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with root privileges. To successfully exploit this vulnerability, an attacker would need at least valid Operator credentials.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-secure_email_gateway_c695secure_email_gateway_virtual_appliance_c600vsecure_email_gateway_c195asyncossecure_email_gateway_c395secure_email_gateway_virtual_appliance_c100vsecure_email_gateway_virtual_appliance_c300vCisco Secure Emailsecure_email
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2021-43837
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.4||HIGH
EPSS-9.55% / 92.54%
||
7 Day CHG~0.00%
Published-16 Dec, 2021 | 18:55
Updated-04 Aug, 2024 | 04:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Template injection in vault-cli

vault-cli is a configurable command-line interface tool (and python library) to interact with Hashicorp Vault. In versions before 3.0.0 vault-cli features the ability for rendering templated values. When a secret starts with the prefix `!template!`, vault-cli interprets the rest of the contents of the secret as a Jinja2 template. Jinja2 is a powerful templating engine and is not designed to safely render arbitrary templates. An attacker controlling a jinja2 template rendered on a machine can trigger arbitrary code, making this a Remote Code Execution (RCE) risk. If the content of the vault can be completely trusted, then this is not a problem. Otherwise, if your threat model includes cases where an attacker can manipulate a secret value read from the vault using vault-cli, then this vulnerability may impact you. In 3.0.0, the code related to interpreting vault templated secrets has been removed entirely. Users are advised to upgrade as soon as possible. For users unable to upgrade a workaround does exist. Using the environment variable `VAULT_CLI_RENDER=false` or the flag `--no-render` (placed between `vault-cli` and the subcommand, e.g. `vault-cli --no-render get-all`) or adding `render: false` to the vault-cli configuration yaml file disables rendering and removes the vulnerability. Using the python library, you can use: `vault_cli.get_client(render=False)` when creating your client to get a client that will not render templated secrets and thus operates securely.

Action-Not Available
Vendor-vault-cli_projectpeopledoc
Product-vault-clivault-cli
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2024-11655
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.51% / 80.45%
||
7 Day CHG~0.00%
Published-25 Nov, 2024 | 04:31
Updated-12 Feb, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_pinginterface command injection

A vulnerability classified as critical was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This vulnerability affects unknown code of the file /admin/network/diag_pinginterface. The manipulation of the argument diag_ping leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengenius
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTens620extens500-acenh1350ext
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-11652
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.39% / 58.95%
||
7 Day CHG~0.00%
Published-25 Nov, 2024 | 03:00
Updated-12 Feb, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT sn_https command injection

A vulnerability was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /admin/sn_package/sn_https. The manipulation of the argument https_enable leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengeniustech
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTenh1350ext_firmwareens500-ac_firmwareens620ext_firmware
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-43782
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.7||MEDIUM
EPSS-1.33% / 79.14%
||
7 Day CHG~0.00%
Published-15 Dec, 2021 | 19:30
Updated-04 Aug, 2024 | 04:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Indirect LDAP injection in Tuleap

Tuleap is a Libre and Open Source tool for end to end traceability of application and system developments. This is a follow up to GHSA-887w-pv2r-x8pm/CVE-2021-41276, the initial fix was incomplete. Tuleap does not sanitize properly the search filter built from the ldap_id attribute of a user during the daily synchronization. A malicious user could force accounts to be suspended or take over another account by forcing the update of the ldap_uid attribute. Note that the malicious user either need to have site administrator capability on the Tuleap instance or be an LDAP operator with the capability to create/modify account. The Tuleap instance needs to have the LDAP plugin activated and enabled for this issue to be exploitable. The following versions contain the fix: Tuleap Community Edition 13.2.99.83, Tuleap Enterprise Edition 13.1-6, and Tuleap Enterprise Edition 13.2-4.

Action-Not Available
Vendor-Enalean SAS
Product-tuleaptuleap
CWE ID-CWE-90
Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-11657
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.51% / 80.45%
||
7 Day CHG~0.00%
Published-25 Nov, 2024 | 05:31
Updated-12 Feb, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_nslookup command injection

A vulnerability, which was classified as critical, was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. Affected is an unknown function of the file /admin/network/diag_nslookup. The manipulation of the argument diag_nslookup leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengenius
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTens620extens500-acenh1350ext
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-11654
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.51% / 80.45%
||
7 Day CHG~0.00%
Published-25 Nov, 2024 | 04:00
Updated-12 Feb, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_traceroute6 command injection

A vulnerability classified as critical has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This affects an unknown part of the file /admin/network/diag_traceroute6. The manipulation of the argument diag_traceroute6 leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengenius
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTens620extens500-acenh1350ext
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-11653
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.51% / 80.45%
||
7 Day CHG~0.00%
Published-25 Nov, 2024 | 03:31
Updated-12 Feb, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_traceroute command injection

A vulnerability was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. It has been rated as critical. Affected by this issue is some unknown functionality of the file /admin/network/diag_traceroute. The manipulation of the argument diag_traceroute leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengenius
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTens620extens500-acenh1350ext
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-11651
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.16% / 77.70%
||
7 Day CHG~0.00%
Published-25 Nov, 2024 | 02:31
Updated-12 Feb, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT wifi_schedule command injection

A vulnerability was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. It has been classified as critical. Affected is an unknown function of the file /admin/network/wifi_schedule. The manipulation of the argument wifi_schedule_day_em_5 leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengeniustech
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTenh1350ext_firmwareens500-ac_firmwareens620ext_firmware
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-11659
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.51% / 80.45%
||
7 Day CHG~0.00%
Published-25 Nov, 2024 | 06:31
Updated-12 Feb, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_iperf command injection

A vulnerability was found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118 and classified as critical. Affected by this issue is some unknown functionality of the file /admin/network/diag_iperf. The manipulation of the argument iperf leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengenius
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTens620extens500-acenh1350ext
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-11213
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.09% / 27.16%
||
7 Day CHG~0.00%
Published-14 Nov, 2024 | 16:00
Updated-19 Nov, 2024 | 15:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SourceCodester Best Employee Management System edit_role.php sql injection

A vulnerability, which was classified as critical, was found in SourceCodester Best Employee Management System 1.0. This affects an unknown part of the file /admin/edit_role.php. The manipulation of the argument id leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-mayuri_kSourceCodester
Product-best_employee_management_systemBest Employee Management Systembest_employee_management_system
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-11658
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.51% / 80.45%
||
7 Day CHG~0.00%
Published-25 Nov, 2024 | 06:00
Updated-12 Feb, 2025 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT ajax_getChannelList command injection

A vulnerability has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /admin/network/ajax_getChannelList. The manipulation of the argument countryCode leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengeniustech
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTenh1350ext_firmwareens500-ac_firmwareens620ext_firmware
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-11656
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.51% / 80.45%
||
7 Day CHG~0.00%
Published-25 Nov, 2024 | 05:00
Updated-12 Feb, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
EnGenius ENH1350EXT/ENS500-AC/ENS620EXT diag_ping6 command injection

A vulnerability, which was classified as critical, has been found in EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118. This issue affects some unknown processing of the file /admin/network/diag_ping6. The manipulation of the argument diag_ping6 leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-engeniustechEnGeniusengenius
Product-ens620extens500-ac_firmwareenh1350ext_firmwareenh1350extens500-acens620ext_firmwareENH1350EXTENS500-ACENS620EXTens620extens500-acenh1350ext
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-41282
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-91.88% / 99.68%
||
7 Day CHG~0.00%
Published-01 Mar, 2022 | 22:45
Updated-04 Aug, 2024 | 03:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

diag_routes.php in pfSense 2.5.2 allows sed data injection. Authenticated users are intended to be able to view data about the routes set in the firewall. The data is retrieved by executing the netstat utility, and then its output is parsed via the sed utility. Although the common protection mechanisms against command injection (i.e., the usage of the escapeshellarg function for the arguments) are used, it is still possible to inject sed-specific code and write an arbitrary file in an arbitrary location.

Action-Not Available
Vendor-pfsensen/a
Product-pfsensen/a
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-11058
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.10% / 28.94%
||
7 Day CHG+0.01%
Published-10 Nov, 2024 | 23:00
Updated-13 Nov, 2024 | 23:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
CodeAstro Real Estate Management System About Us Page aboutedit.php sql injection

A vulnerability was found in CodeAstro Real Estate Management System up to 1.0. It has been declared as critical. This vulnerability affects unknown code of the file /aboutedit.php of the component About Us Page. The manipulation of the argument id leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-surajkumarvishwakarmaCodeAstro
Product-real_estate_management_systemReal Estate Management Systemreal_estate_management_system
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-11124
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.09% / 26.56%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 13:31
Updated-15 Nov, 2024 | 22:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TimGeyssens UIOMatic uioMaticObject.r sql injection

A vulnerability has been found in TimGeyssens UIOMatic 5 and classified as critical. This vulnerability affects unknown code of the file /src/UIOMatic/wwwroot/backoffice/resources/uioMaticObject.r. The manipulation leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-timgeyssensTimGeyssens
Product-ui-o-maticUIOMatic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-10946
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.10% / 28.71%
||
7 Day CHG+0.01%
Published-07 Nov, 2024 | 03:31
Updated-11 Dec, 2024 | 19:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Guangzhou Tuchuang Computer Software Development Interlib Library Cluster Automation Management System SysLib sql injection

A vulnerability classified as critical has been found in Guangzhou Tuchuang Computer Software Development Interlib Library Cluster Automation Management System up to 2.0.1. This affects an unknown part of the file /interlib/admin/SysLib?cmdACT=inputLIBCODE&mod=batchXSL&xsl=editLIBCODE.xsl&libcodes=&ROWID=. The manipulation of the argument sql leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-guangzhou_tuchuangGuangzhou Tuchuang Computer Software Developmenttcsoft
Product-interlibInterlib Library Cluster Automation Management Systeminterlib_library_cluster_automation_management_system
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2022-31665
Matching Score-4
Assigner-VMware by Broadcom
ShareView Details
Matching Score-4
Assigner-VMware by Broadcom
CVSS Score-7.2||HIGH
EPSS-6.71% / 90.87%
||
7 Day CHG+0.86%
Published-05 Aug, 2022 | 15:06
Updated-03 Aug, 2024 | 07:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VMware Workspace ONE Access, Identity Manager and vRealize Automation contain a remote code execution vulnerability. A malicious actor with administrator and network access can trigger a remote code execution.

Action-Not Available
Vendor-n/aLinux Kernel Organization, IncVMware (Broadcom Inc.)Microsoft Corporation
Product-linux_kernelidentity_manager_connectorone_accesswindowsidentity_managerVMware Workspace ONE Access, Identity Manager and vRealize Automation
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2024-10947
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.10% / 28.71%
||
7 Day CHG+0.01%
Published-07 Nov, 2024 | 03:31
Updated-11 Dec, 2024 | 19:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Guangzhou Tuchuang Computer Software Development Interlib Library Cluster Automation Management System BatchOrder sql injection

A vulnerability classified as critical was found in Guangzhou Tuchuang Computer Software Development Interlib Library Cluster Automation Management System up to 2.0.1. This vulnerability affects unknown code of the file /interlib/order/BatchOrder?cmdACT=admin_order&xsl=adminOrder_OrderList.xsl. The manipulation of the argument bookrecno leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-guangzhou_tuchuangGuangzhou Tuchuang Computer Software Developmenttcsoft
Product-interlibInterlib Library Cluster Automation Management Systeminterlib_library_cluster_automation_management_system
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2021-41276
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-6.7||MEDIUM
EPSS-1.21% / 78.17%
||
7 Day CHG~0.00%
Published-15 Dec, 2021 | 19:30
Updated-04 Aug, 2024 | 03:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Indirect LDAP injection in Tuleap

Tuleap is a Libre and Open Source tool for end to end traceability of application and system developments. In affected versions Tuleap does not sanitize properly the search filter built from the ldap_id attribute of a user during the daily synchronization. A malicious user could force accounts to be suspended or take over another account by forcing the update of the ldap_uid attribute. Note that the malicious user either need to have site administrator capability on the Tuleap instance or be an LDAP operator with the capability to create/modify account. The Tuleap instance needs to have the LDAP plugin activated and enabled for this issue to be exploitable. This issue has been patched in Tuleap Community Edition 13.2.99.31, Tuleap Enterprise Edition 13.1-5, and Tuleap Enterprise Edition 13.2-3.

Action-Not Available
Vendor-Enalean SAS
Product-tuleaptuleap
CWE ID-CWE-90
Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2015-7544
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-9.1||CRITICAL
EPSS-0.93% / 75.09%
||
7 Day CHG~0.00%
Published-25 Sep, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

redhat-support-plugin-rhev in Red Hat Enterprise Virtualization Manager (aka RHEV Manager) before 3.6 allows remote authenticated users with the SuperUser role on any Entity to execute arbitrary commands on any host in the RHEV environment.

Action-Not Available
Vendor-n/aRed Hat, Inc.
Product-enterprise_virtualization_managern/a
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2022-31658
Matching Score-4
Assigner-VMware by Broadcom
ShareView Details
Matching Score-4
Assigner-VMware by Broadcom
CVSS Score-7.2||HIGH
EPSS-7.73% / 91.55%
||
7 Day CHG~0.00%
Published-05 Aug, 2022 | 15:07
Updated-03 Aug, 2024 | 07:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VMware Workspace ONE Access, Identity Manager and vRealize Automation contain a remote code execution vulnerability. A malicious actor with administrator and network access can trigger a remote code execution.

Action-Not Available
Vendor-n/aLinux Kernel Organization, IncVMware (Broadcom Inc.)Microsoft Corporation
Product-access_connectorlinux_kernelidentity_manager_connectorone_accesswindowsidentity_managerVMware Workspace ONE Access, Identity Manager and vRealize Automation
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2021-35505
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-3.20% / 86.50%
||
7 Day CHG~0.00%
Published-05 Oct, 2021 | 12:00
Updated-04 Aug, 2024 | 00:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Afian FileRun 2021.03.26 allows Remote Code Execution (by administrators) via the Check Path value for the magick binary.

Action-Not Available
Vendor-afiann/a
Product-filerunn/a
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2015-2180
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.74% / 85.41%
||
7 Day CHG~0.00%
Published-30 Jan, 2017 | 22:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The DBMail driver in the Password plugin in Roundcube before 1.1.0 allows remote attackers to execute arbitrary commands via shell metacharacters in the password.

Action-Not Available
Vendor-n/aRoundcube Webmail Project
Product-webmailn/a
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2021-36313
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-9.1||CRITICAL
EPSS-1.04% / 76.50%
||
7 Day CHG~0.00%
Published-23 Nov, 2021 | 20:00
Updated-16 Sep, 2024 | 18:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell EMC CloudLink 7.1 and all prior versions contain an OS command injection Vulnerability. A remote high privileged attacker, may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker. This vulnerability is considered critical as it may be leveraged to completely compromise the vulnerable application as well as the underlying operating system. Dell recommends customers to upgrade at the earliest opportunity.

Action-Not Available
Vendor-Dell Inc.
Product-cloudlinkCloudLink
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-32756
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-1.02% / 76.33%
||
7 Day CHG~0.00%
Published-21 Jul, 2021 | 18:45
Updated-03 Aug, 2024 | 23:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Arbitrary eval through MiqExpression

ManageIQ is an open-source management platform. In versions prior to jansa-4, kasparov-2, and lasker-1, there is a flaw in the MiqExpression module of ManageIQ where a low privilege user could enter a crafted Ruby string which would be evaluated. Successful exploitation will allow an attacker to execute arbitrary code with root privileges on the host system. There are patches for this issue in releases named jansa-4, kasparov-2, and lasker-1. If possible, restrict users, via RBAC, to only the part of the application that they need access to. While MiqExpression is widely used throughout the product, restricting users can limit the surface of the attack.

Action-Not Available
Vendor-manageiqManageIQ
Product-manageiqmanageiq
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2024-11242
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.11% / 30.25%
||
7 Day CHG~0.00%
Published-15 Nov, 2024 | 14:31
Updated-23 Apr, 2025 | 15:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
ZZCMS Keyword Filtering ad_list.php sql injection

A vulnerability was found in ZZCMS 2023. It has been rated as critical. Affected by this issue is some unknown functionality of the file /admin/ad_list.php?action=pass of the component Keyword Filtering. The manipulation of the argument keyword leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-zzcmsn/azzcms
Product-zzcmsZZCMSzzcms
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • Previous
  • 1
  • 2
  • 3
  • Next
Details not found