An issue was discovered in the Infosysta "In-App & Desktop Notifications" app 1.6.13_J8 for Jira. It is possible to obtain a list of all valid Jira usernames without authentication/authorization via the plugins/servlet/nfj/UserFilter?searchQuery=@ URI.
D-Link DAP-1320 A2-V1.21 routers have some web interfaces without authentication requirements, as demonstrated by uplink_info.xml. An attacker can remotely obtain a user's Wi-Fi SSID and password, which could be used to connect to Wi-Fi or perform a dictionary attack.
There are some web interfaces without authentication requirements on D-Link DIR-412 A1-1.14WW routers. An attacker can get the router's log file via log_get.php, which could be used to discover the intranet network structure.
includes/class-coming-soon-creator.php in the igniteup plugin through 3.4 for WordPress allows information disclosure.
A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) could allow an unauthenticated, remote attacker to access potentially sensitive system usage information. The vulnerability is due to a lack of proper data protection mechanisms. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow an attacker to view sensitive system data.
DTEN D5 and D7 before 1.3.2 devices allows remote attackers to read saved whiteboard image PDF documents via storage/emulated/0/Notes/PDF on TCP port 8080 without authentication.
D-Link DSL-2875AL devices through 1.00.05 are prone to password disclosure via a simple crafted /romfile.cfg request to the web management server. This request doesn't require any authentication and will lead to saving the configuration file. The password is stored in cleartext.
Sphinx Technologies Sphinx 3.1.1 by default has no authentication and listens on 0.0.0.0, making it exposed to the internet (unless filtered by a firewall or reconfigured to listen to 127.0.0.1 only).
A vulnerability in the web-based management interface of Cisco UCS Director could allow an unauthenticated, remote attacker to download system log files from an affected device. The vulnerability is due to an issue in the authentication logic of the web-based management interface. An attacker could exploit this vulnerability by sending a crafted request to the web interface. A successful exploit could allow the attacker to download log files if they were previously generated by an administrator.
Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
In versions 3.0.0-3.5.0, 2.0.0-2.9.0, and 1.0.1, the Neural Autonomic Transport System (NATS) messaging services in use by the NGINX Controller do not require any form of authentication, so any successful connection would be authorized.
Anviz access control devices expose credentials (names and passwords) by allowing remote attackers to query this information without credentials via port tcp/5010.
Lack of authentication in file-viewing components in DDRT Dashcom Live 2019-05-09 allows anyone to remotely access all claim details by visiting easily guessable dashboard/uploads/claim_files/claim_id_ URLs.
In Couchbase Server 6.0.0 and 5.5.0, the eventing service exposes system diagnostic profile via an HTTP endpoint that does not require credentials on a port earmarked for internal traffic only. This has been remedied in version 6.0.1 and now requires valid credentials to access.
A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges.
An unauthenticated attacker can obtain information about the Pydio 8.2.2 configuration including session timeout, libraries, and license information.
The Recruitment module in Humanica Humatrix 7 1.0.0.203 and 1.0.0.681 allows an unauthenticated attacker to access all candidates' files in the photo folder on the website by specifying a "user id" parameter and file name, such as in a recruitment_online/upload/user/[user_id]/photo/[file_name] URI.
Several web pages provided SAP NetWeaver Process Integration (versions: SAP_XIESR: 7.10 to 7.11, 7.20, 7.30, 7.31, 7.40, 7.50 and SAP_XITOOL: 7.10 to 7.11, 7.30, 7.31, 7.40, 7.50) are not password protected. An attacker could access landscape information like host names, ports or other technical data in the absence of restrictive firewall and port settings.
BigAnt Software BigAnt Server v5.6.06 was discovered to contain incorrect access control.
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
A vulnerability in the web-based management interface of Cisco Identity Services Engine (ISE) Software could allow an unauthenticated, remote attacker read tcpdump files generated on an affected device. The vulnerability is due an issue in the authentication logic of the web-based management interface. An attacker could exploit this vulnerability by sending a crafted request to the web interface. A successful exploit could allow the attacker to read a tcpdump file generated with a particular naming scheme.
A vulnerability was found in Papendorf SOL Connect Center 3.3.0.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network. Affected performance IP Cameras: HBD3PR2,H4D3PRV3,HED3PR3,H4D3PRV2,HBD3PR1,H4W8PR2,HBW8PR2,H2W2PC1M,H2W4PER3,H2W2PER3,HEW2PER3,HEW4PER3B,HBW2PER1,HEW4PER2,HEW4PER2B,HEW2PER2,H4W2PER2,HBW2PER2,H4W2PER3, and HPW2P1. Affected Performance Series NVRs: HEN08104,HEN08144,HEN081124,HEN16104,HEN16144,HEN16184,HEN16204,HEN162244,HEN16284,HEN16304,HEN16384,HEN32104,HEN321124,HEN32204,HEN32284,HEN322164,HEN32304, HEN32384,HEN323164,HEN64204,HEN64304,HEN643164,HEN643324,HEN643484,HEN04103,HEN04113,HEN04123,HEN08103,HEN08113,HEN08123,HEN08143,HEN16103,HEN16123,HEN16143,HEN16163,HEN04103L,HEN08103L,HEN16103L,HEN32103L.
A vulnerability classified as problematic was found in Lucky LM-520-SC, LM-520-FSC and LM-520-FSC-SAM up to 20250321. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
In WESEEK GROWI before 3.5.0, a remote attacker can obtain the password hash of the creator of a page by leveraging wiki access to make API calls for page metadata. In other words, the password hash can be retrieved even though it is not a publicly available field.
All configuration parameters of certain Kyocera printers (such as the ECOSYS M5526cdw 2R7_2000.001.701) were accessible by unauthenticated users. This information was only presented in the menus when authenticated, and the pages that loaded this information were also protected. However, all files that contained the configuration parameters were accessible. These files contained sensitive information, such as users, community strings, and other passwords configured in the printer.
Some Brother printers (such as the HL-L8360CDW v1.20) were affected by different information disclosure vulnerabilities that provided sensitive information to an unauthenticated user who visits a specific URL.
An issue was discovered on Samsung mobile devices with O(8.x) software. Access to Gallery in the Secure Folder can occur without authentication. The Samsung ID is SVE-2018-13057 (December 2018).
In IP-AK2 Access Control Panel Version 1.04.07 and prior, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data, which can be accessed without authentication over the network.
IBM Security Identity Governance and Intelligence 5.2.3.2 and 5.2.4 could allow an attacker to obtain sensitive information due to missing authentication in IGI for the survey application. IBM X-Force ID: 148601.
A vulnerability in the Java Remote Method Invocation (RMI) interface of Cisco Unified Customer Voice Portal (CVP) could allow an unauthenticated, remote attacker to access sensitive information on an affected device. The vulnerability exists because certain RMI listeners are not properly authenticated. An attacker could exploit this vulnerability by sending a crafted request to the affected listener. A successful exploit could allow the attacker to access sensitive information on an affected device.
A vulnerability in the Graphite web interface of the Policy and Charging Rules Function (PCRF) of Cisco Policy Suite (CPS) could allow an unauthenticated, remote attacker to access the Graphite web interface. The attacker would need to have access to the internal VLAN where CPS is deployed. The vulnerability is due to lack of authentication. An attacker could exploit this vulnerability by directly connecting to the Graphite web interface. An exploit could allow the attacker to access various statistics and Key Performance Indicators (KPIs) regarding the Cisco Policy Suite environment.
SAP Solution Manager (Diagnostics Agent), version 7.2, does not perform the authentication check for the functionalities of the Collector Simulator, leading to Missing Authentication.
Wipro Holmes Orchestrator 20.4.1 (20.4.1_02_11_2020) allows remote attackers to read application log files containing sensitive information via a predictable /log URI.
IBM Security Guardium 10.5, 10.6, and 11.0 could allow an unauthorized user to obtain sensitive information due to missing security controls. IBM X-Force ID: 141226.
A vulnerability classified as problematic has been found in SourceCodester Book Store Management System 1.0. This affects an unknown part of the file /bsms_ci/index.php/user/edit_user/. The manipulation of the argument password leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-214587.
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.
OpenClinic version 0.8.2 is affected by a missing authentication vulnerability that allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information (PHI) stored in the application, via a direct request for the /tests/ URI.
Splunk Enterprise deployment servers in versions before 9.0 allow unauthenticated downloading of forwarder bundles. Remediation requires you to update the deployment server to version 9.0 and Configure authentication for deployment servers and clients (https://docs.splunk.com/Documentation/Splunk/9.0.0/Security/ConfigDSDCAuthEnhancements#Configure_authentication_for_deployment_servers_and_clients). Once enabled, deployment servers can manage only Universal Forwarder versions 9.0 and higher. Though the vulnerability does not directly affect Universal Forwarders, remediation requires updating all Universal Forwarders that the deployment server manages to version 9.0 or higher prior to enabling the remediation.
A vulnerability in the web interface of Cisco RV132W ADSL2+ Wireless-N VPN Routers and Cisco RV134W VDSL2 Wireless-AC VPN Routers could allow an unauthenticated, remote attacker to view configuration parameters for an affected device, which could lead to the disclosure of confidential information. The vulnerability is due to the absence of user authentication requirements for certain pages that are part of the web interface and contain confidential information for an affected device. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device and examining the HTTP response to the request. A successful exploit could allow the attacker to view configuration parameters, including the administrator password, for the affected device. Cisco Bug IDs: CSCvg92739, CSCvh60172.
A vulnerability was found in 20120630 Novel-Plus up to 0e156c04b4b7ce0563bef6c97af4476fcda8f160. It has been rated as critical. Affected by this issue is the function list of the file novel-system/src/main/java/com/java2nb/system/controller/SessionController.java. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. Attackers can discover cleartext web-server credentials via certain /opt/lighttpd/web/cgi/ requests.
Anviz access control devices expose private Information (pin code and name) by allowing remote attackers to query this information without credentials via port tcp/5010.
Incorrect Access Control in the configuration backup path in SAGEMCOM F@ST3486 NET DOCSIS 3.0, software NET_4.109.0, allows remote unauthenticated users to download the router configuration file via the /backupsettings.conf URI, when any valid session is running.
Lack of authentication in case-exporting components in DDRT Dashcom Live through 2019-05-08 allows anyone to remotely access all claim details by visiting easily guessable exportpdf/all_claim_detail.php?claim_id= URLs.
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow unauthenticated users to extract internal configuration details.
The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.
An issue was discovered in Chadha PHPKB 9.0 Enterprise Edition. installer/test-connection.php (part of the installation process) allows a remote unauthenticated attacker to disclose local files on hosts running PHP before 7.2.16, or on hosts where the MySQL ALLOW LOCAL DATA INFILE option is enabled.