Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.
Grandstream GRP261x VoIP phone running firmware version 1.0.3.6 (Base) allow Authentication Bypass in its administrative web interface.
A vulnerability in the Policy Builder interface of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to access the Policy Builder interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by accessing the Policy Builder interface. A successful exploit could allow the attacker to make changes to existing repositories and create new repositories. Cisco Bug IDs: CSCvi35109.
Improper Authentication vulnerability in Abdul Hakeem Build App Online allows Privilege Escalation.This issue affects Build App Online: from n/a through 1.0.19.
In SapphireIMS 5.0, it is possible to take over an account by sending a request to the Save_Password form as shown in POC. Notice that we do not require a JSESSIONID in this request and can reset any user’s password by changing the username to that user and password to base64(desired password).
A vulnerability in the Redis implementation used by the Cisco Policy Suite for Mobile and Cisco Policy Suite Diameter Routing Agent software could allow an unauthenticated, remote attacker to modify key-value pairs for short-lived events stored by the Redis server. The vulnerability is due to improper authentication when accessing the Redis server. An unauthenticated attacker could exploit this vulnerability by modifying key-value pairs stored within the Redis server database. An exploit could allow the attacker to reduce the efficiency of the Cisco Policy Suite for Mobile and Cisco Policy Suite Diameter Routing Agent software.
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 Version 3.37 and prior, G-50-W Version 3.37 and prior, G-50A Version 3.37 and prior, GB-50 Version 3.37 and prior, GB-50A Version 3.37 and prior, GB-24A Version 9.12 and prior, G-150AD Version 3.21 and prior, AG-150A-A Version 3.21 and prior, AG-150A-J Version 3.21 and prior, GB-50AD Version 3.21 and prior, GB-50ADA-A Version 3.21 and prior, GB-50ADA-J Version 3.21 and prior, EB-50GU-A Version 7.11 and prior, EB-50GU-J Version 7.11 and prior, AE-200J Version 8.01 and prior, AE-200A Version 8.01 and prior, AE-200E Version 8.01 and prior, AE-50J Version 8.01 and prior, AE-50A Version 8.01 and prior, AE-50E Version 8.01 and prior, EW-50J Version 8.01 and prior, EW-50A Version 8.01 and prior, EW-50E Version 8.01 and prior, TE-200A Version 8.01 and prior, TE-50A Version 8.01 and prior, TW-50A Version 8.01 and prior, and CMS-RMD-J Version 1.40 and prior allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
A vulnerability in the Open Systems Gateway initiative (OSGi) interface of Cisco Policy Suite before 18.1.0 could allow an unauthenticated, remote attacker to directly connect to the OSGi interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by directly connecting to the OSGi interface. An exploit could allow the attacker to access or change any files that are accessible by the OSGi process. Cisco Bug IDs: CSCvh18017.
newbee-mall all versions are affected by incorrect access control to remotely gain privileges through AdminLoginInterceptor.java. The authentication logic of the system's background /admin is in code AdminLoginInterceptor, which can be bypassed.
An issue was discovered in the box application on HiSilicon based IPTV/H.264/H.265 video encoders. The file-upload endpoint does not enforce authentication. Attackers can send an unauthenticated HTTP request to upload a custom firmware component, possibly in conjunction with command injection, to achieve arbitrary code execution.
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
VR CAM P1 Model P1 v1 has an incorrect access control vulnerability where an attacker can obtain complete access of the device from web (remote) without authentication.
SICK Package Analytics software up to and including version V04.0.0 are vulnerable to an authentication bypass by directly interfacing with the REST API. An attacker can send unauthorized requests, bypass current authentication controls presented by the application and could potentially write files without authentication.
The Appbase streams Docker image 2.1.2 contains a blank password for the root user. Systems deployed using affected versions of the streams container may allow a remote attacker to achieve root access with a blank password.
An issue was discovered in Electerm 1.3.22, allows attackers to execute arbitrary code via unverified request to electerms service.
D-Link DWL-900AP+ Access Point 2.1 and 2.2 allows remote attackers to access the TFTP server without authentication and read the config.img file, which contains sensitive information such as the administrative password, the WEP encryption keys, and network configuration information.
NetAlertX is a network, presence scanner and alert framework. Prior to version 25.4.14, it is possible to bypass the authentication mechanism of NetAlertX to update settings without authentication. An attacker can trigger sensitive functions within util.php by sending crafted requests to /index.php. This issue has been patched in version 25.4.14.
Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service.
IBM Spectrum Protect Server 8.1 through 8.1.26 could allow attacker to bypass authentication due to improper session authentication which can result in access to unauthorized resources.
CouchDB version 3.0.0 shipped with a new configuration setting that governs access control to the entire database server called `require_valid_user_except_for_up`. It was meant as an extension to the long standing setting `require_valid_user`, which in turn requires that any and all requests to CouchDB will have to be made with valid credentials, effectively forbidding any anonymous requests. The new `require_valid_user_except_for_up` is an off-by-default setting that was meant to allow requiring valid credentials for all endpoints except for the `/_up` endpoint. However, the implementation of this made an error that lead to not enforcing credentials on any endpoint, when enabled. CouchDB versions 3.0.1[1] and 3.1.0[2] fix this issue.
The previous default setting for Airflow's Experimental API was to allow all API requests without authentication, but this poses security risks to users who miss this fact. From Airflow 1.10.11 the default has been changed to deny all requests by default and is documented at https://airflow.apache.org/docs/1.10.11/security.html#api-authentication. Note this change fixes it for new installs but existing users need to change their config to default `[api]auth_backend = airflow.api.auth.backend.deny_all` as mentioned in the Updating Guide: https://github.com/apache/airflow/blob/1.10.11/UPDATING.md#experimental-api-will-deny-all-request-by-default
A vulnerability in the web interface of Cisco RV132W ADSL2+ Wireless-N VPN Routers and Cisco RV134W VDSL2 Wireless-AC VPN Routers could allow an unauthenticated, remote attacker to view configuration parameters for an affected device, which could lead to the disclosure of confidential information. The vulnerability is due to the absence of user authentication requirements for certain pages that are part of the web interface and contain confidential information for an affected device. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device and examining the HTTP response to the request. A successful exploit could allow the attacker to view configuration parameters, including the administrator password, for the affected device. Cisco Bug IDs: CSCvg92739, CSCvh60172.
A vulnerability in the Policy Builder database of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to connect directly to the Policy Builder database. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by connecting directly to the Policy Builder database. A successful exploit could allow the attacker to access and change any data in the Policy Builder database. Cisco Bug IDs: CSCvh06134.
Lack of access control in Nakivo Backup & Replication Transporter version 9.4.0.r43656 allows remote users to access unencrypted backup repositories and the Nakivo Controller configuration via a network accessible transporter service. It is also possible to create or delete backup repositories.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
authentik is an open-source Identity Provider. Prior to versions 2023.8.4 and 2023.10.2, when the default admin user has been deleted, it is potentially possible for an attacker to set the password of the default admin user without any authentication. authentik uses a blueprint to create the default admin user, which can also optionally set the default admin users' password from an environment variable. When the user is deleted, the `initial-setup` flow used to configure authentik after the first installation becomes available again. authentik 2023.8.4 and 2023.10.2 fix this issue. As a workaround, ensure the default admin user (Username `akadmin`) exists and has a password set. It is recommended to use a very strong password for this user, and store it in a secure location like a password manager. It is also possible to deactivate the user to prevent any logins as akadmin.
An issue was discovered in Veritas NetBackup 8.0 and earlier and NetBackup Appliance 3.0 and earlier. Unauthenticated CORBA interfaces permit inappropriate access.
BMC Track-It! 11.3.0.355 does not require authentication on TCP port 9010, which allows remote attackers to upload arbitrary files, execute arbitrary code, or obtain sensitive credential and configuration information via a .NET Remoting request to (1) FileStorageService or (2) ConfigurationService.
Langflow versions prior to 1.3.0 are susceptible to code injection in the /api/v1/validate/code endpoint. A remote and unauthenticated attacker can send crafted HTTP requests to execute arbitrary code.
BSS Continuity CMS 4.2.22640.0 has an Authentication Bypass vulnerability
AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity.
It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions of Command Centre v8.20 prior to v8.20.1166(MR3), versions of 8.10 prior to v8.10.1211(MR5), versions of 8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. These credentials can then be used to encode low security cards to be used by the system where insecure card technologies are supported.
Affected versions of Smartstore have a missing WebApi Authentication attribute. This vulnerability affects Smartstore shops in version 4.0.0 & 4.0.1 which have installed and activated the Web API plugin. Users of Smartstore 4.0.0 and 4.0.1 must merge their repository with 4.0.x or overwrite the file SmartStore.Web.Framework in the */bin* directory of the deployed shop with this file. As a workaround without updating uninstall the Web API plugin to close this vulnerability.
Vulnerability of access permissions not being strictly verified in the APPWidget module.Successful exploitation of this vulnerability may cause some apps to run without being authorized.
Advantech iView, versions 5.6 and prior, has an improper authentication for critical function (CWE-306) issue. Successful exploitation of this vulnerability may allow an attacker to obtain the information of the user table, including the administrator credentials in plain text. An attacker may also delete the administrator account.
Garden is an automation platform for Kubernetes development and testing. In versions prior to 0.12.39 multiple endpoints did not require authentication. In some operating modes this allows for an attacker to gain access to the application erroneously. The configuration is leaked through the /api endpoint on the local server that is responsible for serving the Garden dashboard. At the moment, this server is accessible to 0.0.0.0 which makes it accessible to anyone on the same network (or anyone on the internet if they are on a public, static IP). This may lead to the ability to compromise credentials, secrets or environment variables. Users are advised to upgrade to version 0.12.39 as soon as possible. Users unable to upgrade should use a firewall blocking access to port 9777 from all untrusted network machines.
The UI in DevSpace 4.13.0 allows web sites to execute actions on pods (on behalf of a victim) because of a lack of authentication for the WebSocket protocol. This leads to remote code execution.
xlockmore 5.13 and 5.22 segfaults when using libpam-opensc and returns the underlying xsession. This allows unauthorized users access to the X session.
HCL OneTest UI V9.5, V10.0, and V10.1 does not perform authentication for functionality that either requires a provable user identity or consumes a significant amount of resources.
Sing-box is an open source proxy system. Affected versions are subject to an authentication bypass when specially crafted requests are sent to sing-box. This affects all SOCKS5 inbounds with user authentication and an attacker may be able to bypass authentication. Users are advised to update to sing-box 1.4.4 or to 1.5.0-rc.4. Users unable to update should not expose the SOCKS5 inbound to insecure environments.
Vulnerability in the Oracle Scripting product of Oracle E-Business Suite (component: iSurvey Module). Supported versions that are affected are 12.2.3-12.2.14. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Scripting. Successful attacks of this vulnerability can result in takeover of Oracle Scripting. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Authentication Bypass vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to change or update any configuration settings, or gain administrator functionality via a crafted HTTP request parameter.
If Apache TomEE is configured to use the embedded ActiveMQ broker, and the broker URI includes the useJMX=true parameter, a JMX port is opened on TCP port 1099, which does not include authentication. This affects Apache TomEE 8.0.0-M1 - 8.0.1, Apache TomEE 7.1.0 - 7.1.2, Apache TomEE 7.0.0-M1 - 7.0.7, Apache TomEE 1.0.0 - 1.7.5.
GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system.
vBulletin before 5.5.6pl1, 5.6.0 before 5.6.0pl1, and 5.6.1 before 5.6.1pl1 has incorrect access control.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.933 Application 20.0.2368 allows Unauthenticated Driver Package Editing V-2024-008.
Arbitrary code execution vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to execute arbitrary code on affected installations of OBR.
An issue was discovered in CIPPlanner CIPAce 9.1 Build 2019092801. Upload.ashx allows remote attackers to execute arbitrary code by uploading and executing an ASHX file.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.913 Application 20.0.2253 allows Addition of Partial Admin Users Without Authentication V-2024-002.
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.