Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers can fully interact with the device: for example, send the "open door" command, download the users list (which includes RFID codes and passcodes in cleartext), or update/create users. The same attack can be executed on a local network and over the internet (if the device is exposed on a public IP address).
Anviz CrossChex access control management software 4.3.8.0 and 4.3.12 is vulnerable to a buffer overflow vulnerability.
Anviz access control devices allow unverified password change which allows remote attackers to change the administrator password without prior authentication.
Anviz access control devices expose private Information (pin code and name) by allowing remote attackers to query this information without credentials via port tcp/5010.
Anviz access control devices expose credentials (names and passwords) by allowing remote attackers to query this information without credentials via port tcp/5010.
By default, the Packet Power Monitoring and Control Web Interface do not enforce authentication mechanisms. This vulnerability could allow unauthorized users to access and manipulate monitoring and control functions.
Insufficient input validation within GitLab Language Server 7.6.0 and later before 7.30.0 allows arbitrary GraphQL query execution
Missing authentication for critical function in Visual Studio Code extension for Arduino allows an unauthenticated attacker to perform remote code execution through network attack vector.
An authentication bypass vulnerability exists which allows an unauthenticated attacker to control administrator backup functions, leading to compromise of passwords, secrets, and application session tokens stored by the Unified PAM.
Cybele Software Thinfinity Workspace before v7.0.2.113 was discovered to contain an access control issue in the API endpoint where Web Sockets connections are established.
A firmware update vulnerability exists in the login.cgi functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary firmware update. An attacker can send an unauthenticated message to trigger this vulnerability.
D-Link - CWE-288:Authentication Bypass Using an Alternate Path or Channel
The password reset feature of Ai3 QbiBot lacks proper access control, allowing unauthenticated remote attackers to reset any user's password.
A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future.
Minio console is a graphical user interface for the for MinIO operator. Minio itself is a multi-cloud object storage project. Affected versions are subject to an authentication bypass issue in the Operator Console when an external IDP is enabled. All users on release v0.12.2 and before are affected and are advised to update to 0.12.3 or newer. Users unable to upgrade should add automountServiceAccountToken: false to the operator-console deployment in Kubernetes so no service account token will get mounted inside the pod, then disable the external identity provider authentication by unset the CONSOLE_IDP_URL, CONSOLE_IDP_CLIENT_ID, CONSOLE_IDP_SECRET and CONSOLE_IDP_CALLBACK environment variable and instead use the Kubernetes service account token.
A vulnerability was found in SimStudioAI sim up to 37786d371e17d35e0764e1b5cd519d873d90d97b. It has been declared as critical. Affected by this vulnerability is the function POST of the file apps/sim/app/api/files/upload/route.ts of the component Session Handler. The manipulation of the argument Request leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the HM-Print AddOn through 1.2a installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the exec.cgi and exec1.cgi scripts, which execute TCL script content from an HTTP POST request.
In Progress MOVEit Transfer 11.1 before 11.1.3, a vulnerability has been found that could allow an attacker to sign in without full credentials via the SSH (SFTP) interface. The vulnerability affects only certain SSH (SFTP) configurations, and is applicable only if the MySQL database is being used.
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The AdminService is available without authentication on the Application Server. An attacker can use methods exposed via this interface to receive password hashes of other users and to change user passwords. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
eQ-3 Homematic CCU2 2.47.20 and CCU3 3.47.18 with the E-Mail AddOn through 1.6.8.c installed allow Remote Code Execution by unauthenticated attackers with access to the web interface via the save.cgi script for payload upload and the testtcl.cgi script for its execution.
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The HTTP service (default port 5401/tcp) of the SiVMS/SiNVR Video Server contains an authentication bypass vulnerability, even when properly configured with enforced authentication. A remote attacker with network access to the Video Server could exploit this vulnerability to read the SiVMS/SiNVR users database, including the passwords of all users in obfuscated cleartext.
The RSA Identity Governance and Lifecycle and RSA Via Lifecycle and Governance products prior to 7.1.1 P03 contain an Improper Authentication vulnerability. A Java JMX agent running on the remote host is configured with plain text password authentication. An unauthenticated remote attacker can connect to the JMX agent and monitor and manage the Java application.
This vulnerability allows remote attackers to issue commands on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the EA-HTTP.exe process. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to issue commands to the physical equipment controlled by the device. Was ZDI-CAN-10482.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
In JetBrains TeamCity before 2022.04.7, 2022.10.6, 2023.05.6, 2023.11.5 authentication bypass was possible in specific edge cases
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
wan.htm page on Zyxel NBG-418N v2 with firmware version V1.00(AARP.9)C0 can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify data fields of the page.
There are some web interfaces without authentication requirements on D-Link DIR-868L B1-2.03 and DIR-817LW A1-1.04 routers. An attacker can get the router's username and password (and other information) via a DEVICE.ACCOUNT value for SERVICES in conjunction with AUTHORIZED_GROUP=1%0a to getcfg.php. This could be used to control the router remotely.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link DCS-960L v1.07.102. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HNAP service, which listens on TCP port 80 by default. When parsing the SOAPAction request header, the process does not properly validate the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the admin user. Was ZDI-CAN-8458.
Intesync Solismed 3.3sp has Incorrect Access Control.
eQ-3 Homematic CCU2 before 2.47.18 and CCU3 before 3.47.18 allow Remote Code Execution by unauthenticated attackers with access to the web interface via an HTTP POST request to certain URLs related to the ReGa core process.
An issue was discovered in the LifterLMS plugin through 3.34.5 for WordPress. The upload_import function in the class.llms.admin.import.php script is prone to an unauthenticated options import vulnerability that could lead to privilege escalation (administrator account creation), website redirection, and stored XSS.
The nd-restaurant-reservations plugin before 1.5 for WordPress has no requirement for nd_rst_import_settings_php_function authentication.
Victure PC530 devices allow unauthenticated TELNET access as root.
An issue was discovered in Zoho ManageEngine OpManager in builds before 14310. One can bypass the user password requirement and execute commands on the server. The "username+'@opm' string is used for the password. For example, if the username is admin, the password is admin@opm.
Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service.
An issue regarding missing authentication for certain utilities exists in CyberPower PowerPanel Enterprise prior to v2.8.3. An unauthenticated remote attacker can access the PDNU REST APIs, which may result in compromise of the application.
BSS Continuity CMS 4.2.22640.0 has an Authentication Bypass vulnerability
An issue was discovered in Tyto Sahi Pro 6.x through 8.0.0. TestRunner_Non_distributed (and distributed end points) does not have any authentication mechanism. This allow an attacker to execute an arbitrary script on the remote Sahi Pro server. There is also a password-protected web interface intended for remote access to scripts. This web interface lacks server-side validation, which allows an attacker to create/modify/delete a script remotely without any password. Chaining both of these issues results in remote code execution on the Sahi Pro server.
A vulnerability in the Policy Builder interface of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to access the Policy Builder interface. The vulnerability is due to a lack of authentication. An attacker could exploit this vulnerability by accessing the Policy Builder interface. A successful exploit could allow the attacker to make changes to existing repositories and create new repositories. Cisco Bug IDs: CSCvi35109.
A broken access control vulnerability in Smart Battery A4, a multifunctional portable charger, firmware version ?<= r1.7.9 allows an attacker to get/reset administrator’s password without any authentication.
HiNet GPON firmware version < I040GWR190731 allows an attacker login to device without any authentication.
Super Micro SuperDoctor 5, when restrictions are not implemented in agent.cfg, allows remote attackers to execute arbitrary commands via NRPE.
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity.
In ONAP MSB through Dublin, by accessing an applicable port (30234, 30290, 32010, 30270, 30224, 30281, 30254, 30285, and/or 30271), an attacker gains full access to the respective ONAP services without any authentication. All ONAP Operations Manager (OOM) setups are affected.
An issue was discovered in ONAP SDC through Dublin. By accessing port 6000 of demo-sdc-sdc-fe pod, an unauthenticated attacker (who already has access to pod-to-pod communication) may execute arbitrary code inside that pod. All ONAP Operations Manager (OOM) setups are affected.
Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an attacker to enable the SNMP service and manipulate the community strings to achieve further control in.