TELESTAR Bobs Rock Radio, Dabman D10, Dabman i30 Stereo, Imperial i110, Imperial i150, Imperial i200, Imperial i200-cd, Imperial i400, Imperial i450, Imperial i500-bt, and Imperial i600 TN81HH96-g102h-g102 devices have an undocumented TELNET service within the BusyBox subsystem, leading to root access.
On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not).
On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root"). The attacker can make a user that is connected to the repeater click on a malicious link that will log into the telnet and will infect the device with malicious code.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session.
On Shenzhen Cylan Clever Dog Smart Camera DOG-2W and DOG-2W-V4 devices, an attacker on the network can login remotely to the camera and gain root access. The device ships with a hardcoded 12345678 password for the root account, accessible from a TELNET login prompt.
iball Baton 150M iB-WRA150N v1 00000001 1.2.6 build 110401 Rel.47776n devices are prone to an authentication bypass vulnerability that allows remote attackers to view and modify administrative router settings by reading the HTML source code of the password.cgi file.
The Web-GUI on WAGO Series 750-88x (750-330, 750-352, 750-829, 750-831, 750-852, 750-880, 750-881, 750-882, 750-884, 750-885, 750-889) and Series 750-87x (750-830, 750-849, 750-871, 750-872, 750-873) devices has undocumented service access.
WAGO 852-303 before FW06, 852-1305 before FW06, and 852-1505 before FW03 devices contain hardcoded users and passwords that can be used to login via SSH and TELNET.
Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it.
An issue was discovered on the ENTTEC Datagate MK2, Storm 24, Pixelator, and E-Streamer MK2 with firmware 70044_update_05032019-482. They include a hard-coded SSH backdoor for remote SSH and SCP access as the root user. A command in the relocate and relocate_revB scripts copies the hardcoded key to the root user's authorized_keys file, enabling anyone with the associated private key to gain remote root access to all affected products.
NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration.
Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
The Fedora Nagios package uses "nagiosadmin" as the default password for the "nagiosadmin" administrator account, which makes it easier for remote attackers to obtain access by leveraging knowledge of the credentials.
WAGO 852-303 before FW06, 852-1305 before FW06, and 852-1505 before FW03 devices contain hardcoded private keys for the SSH daemon. The fingerprint of the SSH host key from the corresponding SSH daemon matches the embedded private key.
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded System Passwords that provide shell access.
Datto ALTO and SIRIS devices have a default VNC password.
REINER timeCard 6.05.07 installs a Microsoft SQL Server with an sa password that is hardcoded in the TCServer.jar file.
A use of hard-coded credentials (CWE-798) vulnerability in FortiPortal versions 5.2.5 and below, 5.3.5 and below, 6.0.4 and below, versions 5.1.x and 5.0.x may allow a remote and unauthenticated attacker to execute unauthorized commands as root by uploading and deploying malicious web application archive files using the default hard-coded Tomcat Manager username and password.
Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell.
An issue was discovered on Wireless IP Camera 360 devices. A root account with a known SHA-512 password hash exists, which makes it easier for remote attackers to obtain administrative access via a TELNET session.
Versions of DocuTrac QuicDoc and Office Therapy that ship with DTISQLInstaller.exe version 1.6.4.0 and prior contain three credentials with known passwords: QDMaster, OTMaster, and sa.
Backup archives were found to be encrypted with a static password across different installations, which suggest the same password may be used in all virtual appliance instances of Trend Micro Deep Discovery Director 1.1.
AVer Information EH6108H+ devices with firmware X9.03.24.00.07l have hardcoded accounts, which allows remote attackers to obtain root access by leveraging knowledge of the credentials and establishing a TELNET session.
A vulnerability was found in TOTOLINK CP450 4.1.0cu.747_B20191224. It has been classified as critical. This affects an unknown part of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical has been found in TOTOLINK T10 AC1200 4.1.8cu.5207. Affected is an unknown function of the file /squashfs-root/web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
ZModo ZP-NE14-S and ZP-IBH-13W devices have a hardcoded root password, which makes it easier for remote attackers to obtain access via a TELNET session.
Computrols CBAS 18.0.0 has Default Credentials.
An issue was discovered on Glory RBW-100 devices with firmware ISP-K05-02 7.0.0. A hard-coded username and password were identified that allow a remote attacker to gain admin access to the Front Circle Controller web interface.
SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.
Mirasys VMS before V7.6.1 and 8.x before V8.3.2 mishandles the Mirasys.Common.Utils.Security.DataCrypt method in Common.dll in AuditTrailService in SMServer.exe. This method triggers insecure deserialization within the .NET garbage collector, in which a gadget (contained in a serialized object) may be executed with SYSTEM privileges. The attacker must properly encrypt the object; however, the hardcoded keys are available.
ICS/StaticPages/AddTestUsers.aspx in Jenzabar JICS (aka Internet Campus Solution) before 2019-02-06 allows remote attackers to create an arbitrary number of accounts with a password of 1234.
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.
Juniper ATP ships with hard coded credentials in the Web Collector instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
A low privileged admin account with a weak default password of admin exists on the Foxconn FEMTO AP-FC4064-T AP_GT_B38_5.8.3lb15-W47 LTE Build 15. In addition, its web management page relies on the existence or values of cookies when performing security-critical operations. One can gain privileges by modifying cookies.
Juniper ATP ships with hard coded credentials in the Cyphort Core instance which gives an attacker the ability to take full control of any installation of the software. Affected releases are Juniper Networks Juniper ATP: 5.0 versions prior to 5.0.3.
Prisma Industriale Checkweigher PrismaWEB 1.21 allows remote attackers to discover the hardcoded prisma password for the prismaweb account by reading user/scripts/login_par.js.
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
man-group/dtale version 3.10.0 is vulnerable to an authentication bypass and remote code execution (RCE) due to improper input validation. The vulnerability arises from a hardcoded `SECRET_KEY` in the flask configuration, allowing attackers to forge a session cookie if authentication is enabled. Additionally, the application fails to properly restrict custom filter queries, enabling attackers to execute arbitrary code on the server by bypassing the restriction on the `/update-settings` endpoint, even when `enable_custom_filters` is not enabled. This vulnerability allows attackers to bypass authentication mechanisms and execute remote code on the server.
D-Link DIR-620 devices, with a certain Rostelekom variant of firmware 1.0.37, have a hardcoded rostel account, which makes it easier for remote attackers to obtain access via a TELNET session.
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices have a hardcoded password of admin for the admin account, a hardcoded password of support for the support account, and a hardcoded password of user for the user account.
Meross MSS110 devices before 1.1.24 contain a TELNET listener providing access for an undocumented admin account with a blank password.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.