Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D8500 before 1.0.3.58, R6250 before 1.0.4.48, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7900 before 1.0.4.38, R8300 before 1.0.2.144, R8500 before 1.0.2.144, XR300 before 1.0.3.68, R7000P before 1.3.2.132, and R6900P before 1.3.2.132.
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects DC112A before 1.0.0.52, R6400 before 1.0.1.68, RAX200 before 1.0.3.106, WNDR3400v3 before 1.0.1.38, XR300 before 1.0.3.68, R8500 before 1.0.2.144, RAX75 before 1.0.3.106, R8300 before 1.0.2.144, and RAX80 before 1.0.3.106.
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects R6260 before 1.1.0.76, R6800 before 1.2.0.62, R6700v2 before 1.2.0.62, R6900v2 before 1.2.0.62, R7450 before 1.2.0.62, AC2100 before 1.2.0.62, AC2400 before 1.2.0.62, and AC2600 before 1.2.0.62.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, R7000 before 1.0.11.110, R7100LG before 1.0.0.72, R7900 before 1.0.4.30, R8000 before 1.0.4.62, XR300 before 1.0.3.56, R7000P before 1.3.2.132, R8500 before 1.0.2.144, R6900P before 1.3.2.132, and R8300 before 1.0.2.144.
NETGEAR XR1000 devices before 1.0.0.58 are affected by a hardcoded password.
Certain D-Link, Edimax, NETGEAR, TP-Link, Tenda, and Western Digital devices are affected by an integer overflow by an unauthenticated attacker. Remote code execution from the WAN interface (TCP port 20005) cannot be ruled out; however, exploitability was judged to be of "rather significant complexity" but not "impossible." The overflow is in SoftwareBus_dispatchNormalEPMsgOut in the KCodes NetUSB kernel module. Affected NETGEAR devices are D7800 before 1.0.1.68, R6400v2 before 1.0.4.122, and R6700v3 before 1.0.4.122.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7800 before 1.0.1.56, R7800 before 1.0.2.68, R8900 before 1.0.4.26, and R9000 before 1.0.4.26.
NETGEAR WNR2000v3 devices before 1.1.2.14, WNR2000v4 devices before 1.0.0.66, and WNR2000v5 devices before 1.0.0.42 allow authentication bypass and remote code execution via a buffer overflow that uses a parameter in the administration webapp. The NETGEAR ID is PSV-2016-0261.
In NETGEAR ReadyNAS Surveillance before 1.4.3-17 x86 and before 1.1.4-7 ARM, $_GET['uploaddir'] is not escaped and is passed to system() through $tmp_upload_dir, leading to upgrade_handle.php?cmd=writeuploaddir remote command execution.
A vulnerability has been found in Netgear R6900P and R7000P 1.3.3.154 and classified as critical. Affected by this vulnerability is the function sub_16C4C of the component HTTP Header Handler. The manipulation of the argument Host leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Various APC functions accept keys containing null bytes as input, leading to premature truncation of input. This issue affects HHVM versions prior to 3.30.12, all versions between 4.0.0 and 4.8.5, all versions between 4.9.0 and 4.23.1, as well as 4.24.0, 4.25.0, 4.26.0, 4.27.0, 4.28.0, and 4.28.1.