D-Link - CWE-288:Authentication Bypass Using an Alternate Path or Channel
There are some web interfaces without authentication requirements on D-Link DIR-412 A1-1.14WW routers. An attacker can get the router's log file via log_get.php, which could be used to discover the intranet network structure.
An issue discovered on D-Link DIR-615 devices with firmware version 20.05 and 20.07. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
D-Link DSL-2875AL devices through 1.00.05 are prone to password disclosure via a simple crafted /romfile.cfg request to the web management server. This request doesn't require any authentication and will lead to saving the configuration file. The password is stored in cleartext.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use a hidden API URL /goform/SystemCommand to execute a system command without authentication.
An issue was discovered on D-Link DIR-600M 3.02, 3.03, 3.04, and 3.06 devices. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/LoadDefaultSettings to reset the router without authentication.
In D-link DIR-816 A2_v1.10CNB04.img,the network can be reset without authentication via /goform/setMAC.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. A cfm UDP service listening on port 65002 allows remote, unauthenticated exfiltration of administrative credentials.
An issue was discovered on D-Link DIR-816L devices 2.x before 1.10b04Beta02. There exists an exposed administration function in getcfg.php, which can be used to call various services. It can be utilized by an attacker to retrieve various sensitive information, such as admin login credentials, by setting the value of _POST_SERVICES in the query string to DEVICE.ACCOUNT.
SAP Process Integration, business-to-business add-on, versions 1.0, 2.0, does not perform authentication check properly when the default security provider is changed to BouncyCastle (BC), leading to Missing Authentication Check
Vulnerability of lax app identity verification in the pre-authorization function.Successful exploitation of this vulnerability will cause malicious apps to become pre-authorized.
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.
FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to version 1.10.7, FreeSWITCH does not authenticate SIP MESSAGE requests, leading to spam and message spoofing. By default, SIP requests of the type MESSAGE (RFC 3428) are not authenticated in the affected versions of FreeSWITCH. MESSAGE requests are relayed to SIP user agents registered with the FreeSWITCH server without requiring any authentication. Although this behaviour can be changed by setting the `auth-messages` parameter to `true`, it is not the default setting. Abuse of this security issue allows attackers to send SIP MESSAGE messages to any SIP user agent that is registered with the server without requiring authentication. Additionally, since no authentication is required, chat messages can be spoofed to appear to come from trusted entities. Therefore, abuse can lead to spam and enable social engineering, phishing and similar attacks. This issue is patched in version 1.10.7. Maintainers recommend that this SIP message type is authenticated by default so that FreeSWITCH administrators do not need to be explicitly set the `auth-messages` parameter. When following such a recommendation, a new parameter can be introduced to explicitly disable authentication.
In WhatsUp Gold versions released before 2024.0.2, an unauthenticated attacker can configure LDAP settings.
The devices allow access to an unprotected endpoint that allows MPFS file system binary image upload without authentication. The MPFS2 file system module provides a light-weight read-only file system that can be stored in external EEPROM, external serial flash, or internal flash program memory. This file system serves as the basis for the HTTP2 web server module, but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code.
An authentication bypass vulnerability has been found in Repox, which allows a remote user to send a specially crafted POST request, due to the lack of any authentication method, resulting in the alteration or creation of users.
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M and later, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.
An issue was discovered in GitLab Enterprise Edition 11.2.x through 11.4.x before 11.4.13, 11.5.x before 11.5.6, and 11.6.x before 11.6.1. It has Incorrect Access Control.
The web administration server in Solar-Log 500 before 2.8.2 Build 52 does not require authentication, which allows remote attackers to gain administrative privileges by connecting to the server. As a result, the attacker can modify configuration files and change the system status. Fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base.
A Missing Authentication for Critical Function vulnerability in B. Braun SpaceCom2 prior to 012U000062 allows a remote attacker to reconfigure the device from an unknown source because of lack of authentication on proprietary networking commands.
Apache Hive before 3.1.3 "CREATE" and "DROP" function operations does not check for necessary authorization of involved entities in the query. It was found that an unauthorized user can manipulate an existing UDF without having the privileges to do so. This allowed unauthorized or underprivileged users to drop and recreate UDFs pointing them to new jars that could be potentially malicious.
A vulnerability, which was classified as critical, has been found in 20120630 Novel-Plus up to 0e156c04b4b7ce0563bef6c97af4476fcda8f160. This issue affects the function addCrawlSource of the file novel-crawl/src/main/java/com/java2nb/novel/controller/CrawlController.java. The manipulation leads to missing authentication. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered in Emote Remote Mouse through 4.0.0.0. Attackers can maximize or minimize the window of a running process by sending the process name in a crafted packet. This information is sent in cleartext and is not protected by any authentication logic.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to disable an authentication profile server via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to set an arbitrary authentication profile server via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to disable front panel authentication via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable front panel authentication via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to enable an authentication profile server via crafted HTTP requests.
The Thrive Optimize WordPress plugin before 1.4.13.3, Thrive Comments WordPress plugin before 1.4.15.3, Thrive Headline Optimizer WordPress plugin before 1.3.7.3, Thrive Leads WordPress plugin before 2.3.9.4, Thrive Ultimatum WordPress plugin before 2.3.9.4, Thrive Quiz Builder WordPress plugin before 2.3.9.4, Thrive Apprentice WordPress plugin before 2.3.9.4, Thrive Visual Editor WordPress plugin before 2.6.7.4, Thrive Dashboard WordPress plugin before 2.3.9.3, Thrive Ovation WordPress plugin before 2.4.5, Thrive Clever Widgets WordPress plugin before 1.57.1 and Rise by Thrive Themes WordPress theme before 2.0.0, Ignition by Thrive Themes WordPress theme before 2.0.0, Luxe by Thrive Themes WordPress theme before 2.0.0, FocusBlog by Thrive Themes WordPress theme before 2.0.0, Minus by Thrive Themes WordPress theme before 2.0.0, Squared by Thrive Themes WordPress theme before 2.0.0, Voice WordPress theme before 2.0.0, Performag by Thrive Themes WordPress theme before 2.0.0, Pressive by Thrive Themes WordPress theme before 2.0.0, Storied by Thrive Themes WordPress theme before 2.0.0, Thrive Themes Builder WordPress theme before 2.2.4 register a REST API endpoint associated with Zapier functionality. While this endpoint was intended to require an API key in order to access, it was possible to access it by supplying an empty api_key parameter in vulnerable versions if Zapier was not enabled. Attackers could use this endpoint to add arbitrary data to a predefined option in the wp_options table.
On all 7.x and 6.x versions (fixed in 8.0.0), BIG-IQ high availability (HA) when using a Quorum device for automatic failover does not implement any form of authentication with the Corosync daemon. Note: Software versions which have reached End of Software Development (EoSD) are not evaluated.
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications accept unauthenticated file write messages. An unauthenticated remote attacker could write arbitrary files to the affected application's file system.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
Missing authentication when creating and managing the B&R APROL database in versions < R 4.2-07 allows reading and changing the system configuration.
IBM Guardium Data Encryption (GDE) 3.0.0.2 and 4.0.0.4 does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
A vulnerability in the web-based management interface of Cisco HyperFlex HX Data Platform could allow an unauthenticated, remote attacker to upload files to an affected device. This vulnerability is due to missing authentication for the upload function. An attacker could exploit this vulnerability by sending a specific HTTP request to an affected device. A successful exploit could allow the attacker to upload files to the affected device with the permissions of the tomcat8 user.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
Talend Data Catalog remote harvesting server before 8.0-20230413 contains a /upgrade endpoint that allows an unauthenticated WAR file to be deployed on the server. (A mitigation is that the remote harvesting server should be behind a firewall that only allows access to the Talend Data Catalog server.)
An issue was discovered on D-Link DSL-2640B E1 EU_1.01 devices. The administrative interface doesn't perform authentication checks for a firmware-update POST request. Any attacker that can access the administrative interface can install firmware of their choice.
Insecure permissions in cskefu v7.0.1 allows unauthenticated attackers to arbitrarily add administrator accounts.
A vulnerability, which was classified as problematic, was found in TOTOLINK A3700R 9.1.2u.5822_B20200513. Affected is an unknown function of the file /wizard.html of the component Password Reset Handler. The manipulation leads to improper access controls. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272568. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered in Couchbase Server before 7.0.4. The Index Service does not enforce authentication for TCP/TLS servers.
Exploitation of Authentication vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to bypass ATD detection via loose enforcement of authentication and authorization.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.
Apollo is a configuration management system. Prior to version 2.1.0, there are potential security issues if users expose apollo-configservice to the internet, which is not recommended. This is because there is no authentication feature enabled for the built-in eureka service. Malicious hackers may access eureka directly to mock apollo-configservice and apollo-adminservice. Login authentication for eureka was added in version 2.1.0. As a workaround, avoid exposing apollo-configservice to the internet.
Lack of authentication vulnerability. An unauthenticated local user is able to see through the cameras using the web server due to the lack of any form of authentication.
Missing authentication in the SetStudentNotes method in IDAttend’s IDWeb application 3.1.052 and earlier allows modification of student data by unauthenticated attackers.
The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.
Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.