NETGEAR RAX30 lighttpd Misconfiguration Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR RAX30. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the lighttpd HTTP server. The issue results from allowing execution of files from untrusted sources. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-19398.
NETGEAR RAX30 SOAP Request SQL Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR RAX30 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of specific SOAP requests. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the service account. Was ZDI-CAN-19754.
NETGEAR RAX30 soap_serverd Stack-based Buffer Overflow Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR RAX30 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the soap_serverd binary. When parsing SOAP message headers, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-19839.
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects D3600 before 1.0.0.67, D6000 before 1.0.0.67, D6100 before 1.0.0.56, D7800 before 1.0.1.30, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.24, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.96, WNDR4300 before 1.0.2.98, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
NETGEAR R7800 devices before 1.0.2.46 are affected by incorrect configuration of security settings.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25.
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects D7800 before 1.0.1.28, R6100 before 1.0.1.20, R7500 before 1.0.0.118, R7500v2 before 1.0.3.20, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.88, WNDR4300 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.62.
NETGEAR WNR854T devices before 1.5.2 are affected by command execution.
Certain NETGEAR devices are affected by weak cryptography. This affects D7000v2 before 1.0.0.62, D8500 before 1.0.3.50, EX3700 before 1.0.0.84, EX3800 before 1.0.0.84, EX6120 before 1.0.0.54, EX6130 before 1.0.0.36, EX7000 before 1.0.1.90, R6250 before 1.0.4.42, R6400v2 before 1.0.4.98, R6700v3 before 1.0.4.98, R6900P before 1.3.2.124, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7100LG before 1.0.0.56, R7900 before 1.0.4.26, R8000 before 1.0.4.58, R8300 before 1.0.2.134, R8500 before 1.0.2.134, RS400 before 1.5.0.48, WNR3500Lv2 before 1.2.0.62, and XR300 before 1.0.3.50.
An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.
In btm_sec_encrypt_change of btm_sec.cc, there is a possible way to downgrade the link key type due to improperly used crypto. This could lead to paired device escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-12 Android-12LAndroid ID: A-258834033