Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The manipulation results in hard-coded credentials. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
Gynoii has a password of guest for the backdoor guest account and a password of 12345 for the backdoor admin account.
Lens Peek-a-View has a password of 2601hx for the backdoor admin account, a password of user for the backdoor user account, and a password of guest for the backdoor guest account.
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.
The Felan Framework plugin for WordPress is vulnerable to improper authentication in versions up to, and including, 1.1.4. This is due to the hardcoded password in the 'fb_ajax_login_or_register' function and in the 'google_ajax_login_or_register' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, if they registered with facebook or google social login and did not change their password.
Hard-coded accounts may be used to access Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.
iBaby M3S has a password of admin for the backdoor admin account.
The Four-Faith F3x36 router using firmware v2.0.0 is vulnerable to authentication bypass due to hard-coded credentials in the administrative web server. An attacker with knowledge of the credentials can gain administrative access via crafted HTTP requests. This issue appears similar to CVE-2023-32645.
newbee-mall includes pre-seeded administrator accounts in its database initialization script. These accounts are provisioned with a predictable default password. Deployments that initialize or reset the database using the provided schema and fail to change the default administrative credentials may allow unauthenticated attackers to log in as an administrator and gain full administrative control of the application.
A vulnerability classified as critical has been found in TOTOLINK T10 AC1200 4.1.8cu.5207. Affected is an unknown function of the file /squashfs-root/web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Certain switch models from PLANET Technology have a Hard-coded community string in the SNMPv1 service, allowing unauthorized remote attackers to use this community string to access the SNMPv1 service with read-write privileges.
OMICARD EDM has a hard-coded machine key. An unauthenticated remote attacker can use the machine key to send serialized payload to the server to execute arbitrary code, manipulate system data and disrupt service.
A vulnerability was found in demozx gf_cms 1.0/1.0.1. It has been classified as critical. This affects the function init of the file internal/logic/auth/auth.go of the component JWT Authentication. The manipulation leads to hard-coded credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.2 is able to address this issue. The patch is named be702ada7cb6fdabc02689d90b38139c827458a5. It is recommended to upgrade the affected component.
A clone version of an ELM327 OBD2 Bluetooth device has a hardcoded PIN, leading to arbitrary commands to an OBD-II bus of a vehicle.
Use of hard-coded MSSQL credentials in PerkinElmer ProcessPlus on Windows allows an attacker to login remove on all prone installations.This issue affects ProcessPlus: through 1.11.6507.0.
Clinic Image System developed by Changing contains hard-coded Credentials, allowing unauthenticated remote attackers to log into the system using administrator credentials embedded in the source code.
The Web Panel in Netsweeper before 4.0.5 has a default password of branding for the branding account, which makes it easier for remote attackers to obtain access via a request to webadmin/.
A vulnerability was found in TOTOLINK CP450 4.1.0cu.747_B20191224. It has been classified as critical. This affects an unknown part of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
The default credentials for the setup HSQL database (HSQLDB) for FileCatalyst Workflow are published in a vendor knowledgebase article. Misuse of these credentials could lead to a compromise of confidentiality, integrity, or availability of the software. The HSQLDB is only included to facilitate installation, has been deprecated, and is not intended for production use per vendor guides. However, users who have not configured FileCatalyst Workflow to use an alternative database per recommendations are vulnerable to attack from any source that can reach the HSQLDB.
TL-WR845N(UN)_V4_200909 and TL-WR845N(UN)_V4_190219 was discovered to contain a hardcoded password for the root account which can be obtained by analyzing downloaded firmware or via a brute force attack through physical access to the router.
The demo feature in Oracle GlassFish Open Source Edition 5.0 has TCP port 7676 open by default with a password of admin for the admin account. This allows remote attackers to obtain potentially sensitive information, perform database operations, or manipulate the demo via a JMX RMI session, aka a "jmx_rmi remote monitoring and control problem." NOTE: this is not an Oracle supported product.
MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs.
Ubiquiti U6-LR 6.6.65 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: In Ubiquiti's view there is no vulnerability as the Hardcoded Password should be after setup not before.
TRENDnet TEW-823DRU devices with firmware before 1.00b36 have a hardcoded password of kcodeskcodes for the root account, which makes it easier for remote attackers to obtain access via an FTP session.
The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.
libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201.
ui/pref/ProxyPrefView.java in weasis-core in Weasis 4.5.1 has a hardcoded key for symmetric encryption of proxy credentials.
Arkeia Network Backup Client 5.x contains hard-coded credentials that effectively serve as a back door, which allows remote attackers to access the file system and possibly execute arbitrary commands.
Weak JWT Secret vulnerabilitiy in EasyVirt DCScope <= 8.6.0 and CO2Scope <= 1.3.0 allows remote attackers to generate JWT for privilege escalation. The HMAC secret used for generating tokens is hardcoded as "somerandomaccesstoken". A weak HMAC secret poses a risk because attackers can use the predictable secret to create valid JSON Web Tokens (JWTs), allowing them access to important information and actions within the application.
SAP Commerce, versions - 6.7, 1808, 1811, 1905, and SAP Commerce (Data Hub), versions - 6.7, 1808, 1811, 1905, allows an attacker to bypass the authentication and/or authorization that has been configured by the system administrator due to the use of Hardcoded Credentials.
A vulnerability in Cisco Smart Licensing Utility (CSLU) could allow an unauthenticated, remote attacker to log into an affected system by using a static administrative credential. This vulnerability is due to an undocumented static user credential for an administrative account. An attacker could exploit this vulnerability by using the static credentials to login to the affected system. A successful exploit could allow the attacker to login to the affected system with administrative rights over the CSLU application API.
Softing FG-100 PB PROFIBUS firmware version FG-x00-PB_V2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session.
EMV DiskXtender 6.20.060 has a hard-coded login and password, which allows remote attackers to bypass authentication via the RPC interface.
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.
Encrypted database credentials in LaborOfficeFree affecting version 19.10. This vulnerability allows an attacker to read and extract the username and password from the database of 'LOF_service.exe' and 'LaborOfficeFree.exe' located in the '%programfiles(x86)%\LaborOfficeFree\' directory. This user can log in remotely and has root-like privileges.
Echelon SmartServer 2.2 with i.LON Vision 2.2 stores cleartext credentials in a file, which could allow an attacker to obtain cleartext usernames and passwords of the SmartServer. If the attacker obtains the file, then the credentials could be used to control the web user interface and file transfer protocol (FTP) server.
Hard-coded credentials are used by the CyberPower PowerPanel platform to authenticate to the database, other services, and the cloud. This could result in an attacker gaining access to services with the privileges of a Powerpanel business application.
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
LB-LINK BL-WR 1300H v.1.0.4 contains hardcoded credentials stored in /etc/shadow which are easily guessable.
ZyXEL ZyWALL 1050 has a hard-coded password for the Quagga and Zebra processes that is not changed when it is set by a user, which allows remote attackers to gain privileges.
A security issue was discovered in the Kubernetes Image Builder versions <= v0.1.37 where default credentials are enabled during the image build process. Virtual machine images built using the Proxmox provider do not disable these default credentials, and nodes using the resulting images may be accessible via these default credentials. The credentials can be used to gain root access. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project with its Proxmox provider.
A vulnerability in Cisco Digital Network Architecture (DNA) Center could allow an unauthenticated, remote attacker to log in to an affected system by using an administrative account that has default, static user credentials. The vulnerability is due to the presence of undocumented, static user credentials for the default administrative account for the affected software. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands with root privileges. This vulnerability affects all releases of Cisco DNA Center Software prior to Release 1.1.3. Cisco Bug IDs: CSCvh98929.
An issue was discovered in Infiray IRAY-A8Z3 1.0.957. The binary file /usr/local/sbin/webproject/set_param.cgi contains hardcoded credentials to the web application. Because these accounts cannot be deactivated or have their passwords changed, they are considered to be backdoor accounts.
USR IOT 4G LTE Industrial Cellular VPN Router v1.0.36 was discovered to contain hard-coded credentials for its highest privileged account. The credentials cannot be altered through normal operation of the device.
SunGrow iSolarCloud Android application V2.1.6.20241017 and prior contains hardcoded credentials. The application (regardless of the user account) and the cloud uses the same MQTT credentials for exchanging the device telemetry.
Rakuten Casa version AP_F_V1_4_1 or AP_F_V2_0_0 uses a hard-coded credential which may allow a remote unauthenticated attacker to log in with the root privilege and perform an arbitrary operation.
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.