ILIAS 5.1.x, 5.2.x, and 5.3.x before 5.3.5 redirects a logged-in user to a third-party site via the return_to_url parameter.
Websites directing users to long URLs that caused eliding to occur in the location view could leverage the truncating behavior to potentially trick users into thinking they were on a different webpage This vulnerability affects Focus < 138.
Open redirect vulnerability in URL-related API functions in Drupal 6.x before 6.35 and 7.x before 7.35 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via vectors involving the "//" initial sequence.
The Advanced Advertising System plugin for WordPress is vulnerable to Open Redirect in all versions up to, and including, 1.3.1. This is due to insufficient validation on the redirect url supplied via the 'redir' parameter. This makes it possible for unauthenticated attackers to redirect users to potentially malicious sites if they can successfully trick them into performing an action.
Open redirect vulnerability in werkzeug before 0.11.6 via a double slash in the URL.
Open Redirection vulnerability in NetIQ Access Manager prior to 5.0.1 and 4.5.4
In Ktor through 1.2.6, the client resends data from the HTTP Authorization header to a redirect location.
A vulnerability in the web interface of Lenovo EZ Media & Backup Center, ix2 & ix2-dl version 4.1.406.34763 and prior could allow an unauthenticated, remote attacker to redirect a user to an untrusted web page.
Secure Entry Server before 4.7.0 contains a URI Redirection vulnerability which could allow remote attackers to conduct phishing attacks due to HSP_AbsoluteRedirects being disabled by default.
Open redirect via parameter ‘p’ in login.php in Centreon (19.04.4 and below) allows an attacker to craft a payload and execute unintended behavior.
A vulnerability in the web-based management interface of Cisco Crosswork Network Services Orchestrator (NSO) could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. This vulnerability is due to improper input validation of a parameter in an HTTP request. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to redirect a user to a malicious website.
A vulnerability, which was classified as critical, has been found in Freshdesk Plugin 1.7 on WordPress. Affected by this issue is some unknown functionality. The manipulation leads to open redirect. The attack may be launched remotely. Upgrading to version 1.8 is able to address this issue. The patch is identified as 2aaecd4e0c7c6c1dc4e6a593163d5f7aa0fa5d5b. It is recommended to upgrade the affected component. VDB-226118 is the identifier assigned to this vulnerability.
A vulnerability, which was classified as problematic, has been found in WooSidebars Plugin up to 1.4.1 on WordPress. Affected by this issue is the function enable_custom_post_sidebars of the file classes/class-woo-sidebars.php. The manipulation of the argument sendback leads to open redirect. The attack may be launched remotely. Upgrading to version 1.4.2 is able to address this issue. The patch is identified as 1ac6d6ac26e185673f95fc1ccc56a392169ba601. It is recommended to upgrade the affected component. VDB-230654 is the identifier assigned to this vulnerability.
Open redirect vulnerability in SEIKO EPSON printers and scanners (DS-570W firmware versions released prior to 2018 March 13, DS-780N firmware versions released prior to 2018 March 13, EP-10VA firmware versions released prior to 2017 September 4, EP-30VA firmware versions released prior to 2017 June 19, EP-707A firmware versions released prior to 2017 August 1, EP-708A firmware versions released prior to 2017 August 7, EP-709A firmware versions released prior to 2017 June 12, EP-777A firmware versions released prior to 2017 August 1, EP-807AB/AW/AR firmware versions released prior to 2017 August 1, EP-808AB/AW/AR firmware versions released prior to 2017 August 7, EP-879AB/AW/AR firmware versions released prior to 2017 June 12, EP-907F firmware versions released prior to 2017 August 1, EP-977A3 firmware versions released prior to 2017 August 1, EP-978A3 firmware versions released prior to 2017 August 7, EP-979A3 firmware versions released prior to 2017 June 12, EP-M570T firmware versions released prior to 2017 September 6, EW-M5071FT firmware versions released prior to 2017 November 2, EW-M660FT firmware versions released prior to 2018 April 19, EW-M770T firmware versions released prior to 2017 September 6, PF-70 firmware versions released prior to 2018 April 20, PF-71 firmware versions released prior to 2017 July 18, PF-81 firmware versions released prior to 2017 September 14, PX-048A firmware versions released prior to 2017 July 4, PX-049A firmware versions released prior to 2017 September 11, PX-437A firmware versions released prior to 2017 July 24, PX-M350F firmware versions released prior to 2018 February 23, PX-M5040F firmware versions released prior to 2017 November 20, PX-M5041F firmware versions released prior to 2017 November 20, PX-M650A firmware versions released prior to 2017 October 17, PX-M650F firmware versions released prior to 2017 October 17, PX-M680F firmware versions released prior to 2017 June 29, PX-M7050F firmware versions released prior to 2017 October 13, PX-M7050FP firmware versions released prior to 2017 October 13, PX-M7050FX firmware versions released prior to 2017 November 7, PX-M7070FX firmware versions released prior to 2017 April 27, PX-M740F firmware versions released prior to 2017 December 4, PX-M741F firmware versions released prior to 2017 December 4, PX-M780F firmware versions released prior to 2017 June 29, PX-M781F firmware versions released prior to 2017 June 27, PX-M840F firmware versions released prior to 2017 November 16, PX-M840FX firmware versions released prior to 2017 December 8, PX-M860F firmware versions released prior to 2017 October 25, PX-S05B/W firmware versions released prior to 2018 March 9, PX-S350 firmware versions released prior to 2018 February 23, PX-S5040 firmware versions released prior to 2017 November 20, PX-S7050 firmware versions released prior to 2018 February 21, PX-S7050PS firmware versions released prior to 2018 February 21, PX-S7050X firmware versions released prior to 2017 November 7, PX-S7070X firmware versions released prior to 2017 April 27, PX-S740 firmware versions released prior to 2017 December 3, PX-S840 firmware versions released prior to 2017 November 16, PX-S840X firmware versions released prior to 2017 December 8, PX-S860 firmware versions released prior to 2017 December 7) allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via the web interface of the affected product.
A vulnerability in the web interface of Cisco Small Business 200, 300, and 500 Series Switches software could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. The vulnerability is due to improper input validation of the parameters of an HTTP request. An attacker could exploit this vulnerability by intercepting a user's HTTP request and modifying it into a request that causes the web interface to redirect the user to a specific malicious URL. This type of vulnerability is known as an open redirect attack and is used in phishing attacks that get users to unknowingly visit malicious sites.
The image thumbnailing handler in Zulip Server versions 1.9.0 to before 2.0.8 allowed an open redirect that was visible to logged-in users.
An issue was discovered in Symfony 2.7.x before 2.7.38, 2.8.x before 2.8.31, 3.2.x before 3.2.14, and 3.3.x before 3.3.13. DefaultAuthenticationSuccessHandler or DefaultAuthenticationFailureHandler takes the content of the _target_path parameter and generates a redirect response, but no check is performed on the path, which could be an absolute URL to an external domain. This Open redirect vulnerability can be exploited for example to mount effective phishing attacks.
Open Redirect vulnerability in Hitachi Device Manager before 8.5.2-01 and Hitachi Tuning Manager before 8.5.2-00 allows remote attackers to redirect authenticated users to arbitrary web sites.
An open redirect vulnerability was discovered in Zoho ManageEngine ADSelfService Plus 5.x before 5809 that allows attackers to force users who click on a crafted link to be sent to a specified external site.
Due to insufficient sanitization in the SAP BusinessObjects Content Administrator Workbench, attackers could craft malicious URLs and execute scripts in a victim�s browser. This could potentially lead to the exposure or modification of web client data, resulting in low impact on confidentiality and integrity, with no impact on application availability.
A cross-site scripting (XSS) vulnerability exists in Grafana caused by combining a client path traversal and open redirect. This allows attackers to redirect users to a website that hosts a frontend plugin that will execute arbitrary JavaScript. This vulnerability does not require editor permissions and if anonymous access is enabled, the XSS will work. If the Grafana Image Renderer plugin is installed, it is possible to exploit the open redirect to achieve a full read SSRF. The default Content-Security-Policy (CSP) in Grafana will block the XSS though the `connect-src` directive.
Open redirect vulnerability in IBM iNotes before 8.5.3 Fix Pack 6 and 9.x before 9.0.1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. IBM X-Force ID: 83383.
In Cloud Foundry router routing-release all versions prior to v0.163.0 and cf-release all versions prior to v274, in some applications, it is possible to append a combination of characters to the URL that will allow for an open redirect. An attacker could exploit this as a phishing attack to gain access to user credentials or other sensitive data. NOTE: 274 resolves the vulnerability but has a serious bug that is fixed in 275.
The WPMobile.App plugin for WordPress is vulnerable to Open Redirect in all versions up to, and including, 11.56. This is due to insufficient validation on the redirect URL supplied via the 'redirect' parameter. This makes it possible for unauthenticated attackers to redirect users to potentially malicious sites if they can successfully trick them into performing an action.
The Jupyter Server provides the backend (i.e. the core services, APIs, and REST endpoints) for Jupyter web applications like Jupyter notebook, JupyterLab, and Voila. In Jupyter Server before version 1.1.1, an open redirect vulnerability could cause the jupyter server to redirect the browser to a different malicious website. All jupyter servers running without a base_url prefix are technically affected, however, these maliciously crafted links can only be reasonably made for known jupyter server hosts. A link to your jupyter server may *appear* safe, but ultimately redirect to a spoofed server on the public internet. This same vulnerability was patched in upstream notebook v5.7.8. This is fixed in jupyter_server 1.1.1. If upgrade is not available, a workaround can be to run your server on a url prefix: "jupyter server --ServerApp.base_url=/jupyter/".
PopojiCMS 2.0.1 allows refer= Open Redirection.
In WordPress before 5.2.3, validation and sanitization of a URL in wp_validate_redirect in wp-includes/pluggable.php could lead to an open redirect if a provided URL path does not start with a forward slash.
SPIP before 3.1.11 and 3.2 before 3.2.5 mishandles redirect URLs in ecrire/inc/headers.php with a %0D, %0A, or %20 character.
An open redirection vulnerability exists in pyload/pyload version 0.5.0. The vulnerability is due to improper handling of the 'next' parameter in the login functionality. An attacker can exploit this vulnerability to redirect users to malicious sites, which can be used for phishing or other malicious activities. The issue is fixed in pyload-ng 0.5.0b3.dev79.
The Affiliate Sales in Google Analytics and other tools plugin for WordPress is vulnerable to Open Redirect in all versions up to, and including, 1.4.9. This is due to insufficient validation on the redirect url supplied via the 'afflink' parameter. This makes it possible for unauthenticated attackers to redirect users to potentially malicious sites if they can successfully trick them into performing an action.
OAuth 2.0 Authorization Server of ForgeRock Access Management (OpenAM) 13.5.0-13.5.1 and Access Management (AM) 5.0.0-5.1.1 does not correctly validate redirect_uri for some invalid requests, which allows attackers to perform phishing via an unvalidated redirect.
Kaspersky Anti-Virus, Kaspersky Internet Security, Kaspersky Total Security, Kaspersky Free Anti-Virus, Kaspersky Small Office Security, Kaspersky Security Cloud up to 2020, the web protection component did not adequately inform the user about the threat of redirecting to an untrusted site. Bypass.
The nd-donations plugin before 1.4 for WordPress has a nopriv_ AJAX action that allows modification of the siteurl setting.
Avi Vantage before 17.2.13 uses an invalid URL encoding during a redirect operation, aka AV-33959.
The simple-301-redirects-addon-bulk-uploader plugin before 1.2.5 for WordPress has no protection against 301 redirect rule injection via a CSV file.
An issue was discovered in the web application in Cherwell Service Management (CSM) 10.2.3. Injection of a malicious payload within the RelayState= parameter of the HTTP request body results in the hijacking of the form action. Form-action hijacking vulnerabilities arise when an application places user-supplied input into the action URL of an HTML form. An attacker can use this vulnerability to construct a URL that, if visited by another application user, will modify the action URL of a form to point to the attacker's server.
An issue was discovered in Alfresco Community Edition versions below 5.2.6, 6.0.N and 6.1.N. The Alfresco Share application is vulnerable to an Open Redirect attack via a crafted POST request. By manipulating the POST parameters, an attacker can redirect a victim to a malicious website over any protocol the attacker desires (e.g.,http, https, ftp, smb, etc.).
An issue was discovered in Verint Impact 360 15.1. At wfo/control/signin, the rd parameter can accept a URL, to which users will be redirected after a successful login. In conjunction with CVE-2019-12784, this can be used by attackers to "crowdsource" bruteforce login attempts on the target site, allowing them to guess and potentially compromise valid credentials without ever sending any traffic from their own machine to the target site.
mod_auth_mellon through 0.14.2 has an Open Redirect via the login?ReturnTo= substring, as demonstrated by omitting the // after http: in the target URL.
Read the Docs before 3.5.1 has an Open Redirect if certain user-defined redirects are used. This affects private instances of Read the Docs (in addition to the public readthedocs.org web sites).
Pollbot is open source software which "frees its human masters from the toilsome task of polling for the state of things during the Firefox release process." In Pollbot before version 1.4.4 there is an open redirection vulnerability in the path of "https://pollbot.services.mozilla.com/". An attacker can redirect anyone to malicious sites. To Reproduce type in this URL: "https://pollbot.services.mozilla.com//evil.com/". Affected versions will redirect to that website when you inject a payload like "//evil.com/". This is fixed in version 1.4.4.
CrushFTP through 8.3.0 is vulnerable to credentials theft via URL redirection.
XWiki is a generic wiki platform. In versions starting from 13.5-rc-1 to before 15.10.13, from 16.0.0-rc-1 to before 16.4.4, and from 16.5.0-rc-1 to before 16.8.0, an open redirect vulnerability in the HTML conversion request filter allows attackers to construct URLs on an XWiki instance that redirects to any URL. This issue has been patched in versions 15.10.13, 16.4.4, and 16.8.0.
The startup.jsp resource in Jira before version 7.13.6, from version 8.0.0 before version 8.2.3, and from version 8.3.0 before version 8.3.2 allows remote attackers to redirect users to a different website which they may use as part of performing a phishing attack via an open redirect.
A vulnerability was found in GLPI up to 10.0.17. It has been declared as problematic. Affected by this vulnerability is an unknown functionality of the file /index.php. The manipulation of the argument redirect leads to open redirect. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 10.0.18 is able to address this issue. It is recommended to upgrade the affected component.
The ChangeSharedFilterOwner resource in Jira before version 7.13.6, from version 8.0.0 before version 8.2.3, and from version 8.3.0 before version 8.3.2 allows remote attackers to attack users, in some cases be able to obtain a user's Cross-site request forgery (CSRF) token, via a open redirect vulnerability.
Spring Security OAuth versions 2.3 prior to 2.3.6, 2.2 prior to 2.2.5, 2.1 prior to 2.1.5, and 2.0 prior to 2.0.18, as well as older unsupported versions could be susceptible to an open redirector attack that can leak an authorization code. A malicious user or attacker can craft a request to the authorization endpoint using the authorization code grant type, and specify a manipulated redirection URI via the redirect_uri parameter. This can cause the authorization server to redirect the resource owner user-agent to a URI under the control of the attacker with the leaked authorization code.
Elgg before 1.12.18 and 2.3.x before 2.3.11 has an open redirect.
In Jupyter Notebook before 5.7.8, an open redirect can occur via an empty netloc. This issue exists because of an incomplete fix for CVE-2019-10255.
An Open Redirect issue was discovered in GitLab Community and Enterprise Edition before 11.7.8, 11.8.x before 11.8.4, and 11.9.x before 11.9.2. A redirect is triggered after successful authentication within the Oauth/:GeoAuthController for the secondary Geo node.