An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A specially-crafted HTTP request can lead to unauthorized access. An attacker can send an HTTP request to trigger this vulnerability.
A vulnerability in the key-based SSH authentication mechanism of Cisco Policy Suite could allow an unauthenticated, remote attacker to log in to an affected system as the root user. This vulnerability is due to the re-use of static SSH keys across installations. An attacker could exploit this vulnerability by extracting a key from a system under their control. A successful exploit could allow the attacker to log in to an affected system as the root user.
ZPanel 10.0.1 has insufficient entropy for its password reset process.
An issue was discovered in Polycom Web Management Interface G3/HDX 8000 HD with Durango 2.6.0 4740 software and embedded Polycom Linux Development Platform 2.14.g3. It has a blank administrative password by default, and can be successfully used without setting this password.
A Hardcoded JWT Secret Key in metadata.py in AdaptiveScale LXDUI through 2.1.3 allows attackers to gain admin access to the host system.
The web application for ProGauge MAGLINK LX4 CONSOLE contains an administrative-level user account with a password that cannot be changed.
admin.php in SmartSiteCMS 1.0 allows remote attackers to bypass authentication and gain administrator privileges by setting the userName cookie.
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.
Multiple MachineSense devices have credentials unable to be changed by the user or administrator.
GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
IBM Security Identity Manager 7.0.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 171511.
The getUserzoneCookie function in Kaltura before 13.2.0 uses a hardcoded cookie secret to validate cookie signatures, which allows remote attackers to bypass an intended protection mechanism and consequently conduct PHP object injection attacks and execute arbitrary PHP code via a crafted userzone cookie.
H3C GR1100-P v100R009 was discovered to use a hardcoded password in /etc/shadow, which allows attackers to log in as root.
H3C R3010 v100R002L02 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root.
A use of hard-coded password vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to gain access through accounts using default passwords
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by hard coded credentials. A hardcoded credential exist in /etc/tomcat8/tomcat-user.xml, which allows attackers to gain authorized access and control the tomcat completely on port 8000 in the tomcat manger page.
In D-Link DIR-860L REVA FIRMWARE PATCH 1.10..B04, the Telnet service contains hardcoded credentials, enabling attackers to log in remotely to the Telnet service and perform arbitrary commands.
D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service.
D-Link DIR-820LW REVB FIRMWARE PATCH 2.03.B01_TC contains hardcoded credentials in the Telnet service, enabling attackers to log in remotely to the Telnet service and perform arbitrary commands.
TX9 Automatic Food Dispenser v3.2.57 devices allow access to a shell as root/superuser, a related issue to CVE-2019-16734. To connect, the telnet service is used on port 23 with the default password of 059AnkJ for the root account. The user can then download the filesystem through preinstalled BusyBox utilities (e.g., tar and nc).
An authentication bypass was found in an unknown area of the SiteOmat source code. All SiteOmat BOS versions are affected, prior to the submission of this exploit. Also, the SiteOmat does not force administrators to switch passwords, leaving SSH and HTTP remote authentication open to public.
GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module.
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability.
Use of hard-coded credentials vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication using hard-coded administrator credentials. These accounts cannot be disabled.
TELSAT marKoni FM Transmitters are vulnerable to an attacker exploiting a hidden admin account that can be accessed through the use of hard-coded credentials.
Dr. ID Door Access Control and Personnel Attendance Management system uses the hard-code admin default credentials that allows remote attackers to access the system through the default password and obtain the highest permission.
Shenzhen Guoxin Synthesis image system before 8.3.0 has a 123456Qw default password.
VinChin Backup & Recovery v5.0.*, v6.0.*, v6.7.*, and v7.0.* was discovered to contain hardcoded credentials.
In PEPPERL+FUCHS WirelessHART-Gateway 3.0.7 to 3.0.9 the SSH and telnet services are active with hard-coded credentials.
A use of hard-coded credentials (CWE-798) vulnerability in FortiPortal versions 5.2.5 and below, 5.3.5 and below, 6.0.4 and below, versions 5.1.x and 5.0.x may allow a remote and unauthenticated attacker to execute unauthorized commands as root by uploading and deploying malicious web application archive files using the default hard-coded Tomcat Manager username and password.
TOTOLINK CP300 V2.0.4-B20201102 was discovered to contain a hardcoded password vulnerability in /etc/shadow.sample, which allows attackers to log in as root.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.
HI-SCAN 6040i Hitrax HX-03-19-I was discovered to contain hardcoded credentials for access to vendor support and service access.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded System Passwords that provide shell access.
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Akkadian Provisioning Manager Engine (PME) ships with a hard-coded credential, akkadianuser:haakkadianpassword. This issue was resolved in Akkadian OVA appliance version 3.0 (and later), Akkadian Provisioning Manager 5.0.2 (and later), and Akkadian Appliance Manager 3.3.0.314-4a349e0 (and later).
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Simple Care software installations. This issue affects Estomed Sp. z o.o. Simple Care software in all versions. The software is no longer supported.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain hard-coded default credentials. An attacker can leverage this vulnerability to execute code in the context of the download user. Was ZDI-CAN-11852.
ZKTeco ZKBio CVSecurity v6.1.1 was discovered to contain a hardcoded cryptographic key.
Use of MAC address as an authenticated password in QSAN Storage Manager, XEVO, SANOS allows local attackers to escalate privileges. Suggest contacting with QSAN and refer to recommendations in QSAN Document.
The vulnerability of hard-coded default credentials in QSAN SANOS allows unauthenticated remote attackers to obtain administrator’s permission and execute arbitrary functions. The referred vulnerability has been solved with the updated version of QSAN SANOS v2.1.0.
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a hardcoded password for telnet in /web_cste/cgi-bin/product.ini, which allows attackers to log in as root.
CyberPower PowerPanel business application code contains a hard-coded set of authentication credentials. This could result in an attacker bypassing authentication and gaining administrator privileges.
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
CyberPower PowerPanel business application code contains a hard-coded JWT signing key. This could result in an attacker forging JWT tokens to bypass authentication.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
luci-app-lucky v2.8.3 was discovered to contain hardcoded credentials.
TOTOLINK EX200 V4.0.3c.7646_B20201211 was discovered to contain a hardcoded password for root at /etc/shadow.sample.