An issue was discovered in Stormshield SNS through 4.2.1. A brute-force attack can occur.
An issue was discovered on Samsung mobile devices with O(8.x) (with TEEGRIS) software. The Gatekeeper Trustlet allows a brute-force attack on user credentials. The Samsung ID is SVE-2020-16908 (June 2020).
CA eHealth Performance Manager through 6.3.2.12 is affected by Improper Restriction of Excessive Authentication Attempts. An attacker is able to perform an arbitrary number of /web/frames/ authentication attempts using different passwords, and eventually gain access to a targeted account, NOTE: This vulnerability only affects products that are no longer supported by the maintainer
It was found that all versions of 3Scale developer portal lacked brute force protections. An attacker could use this gap to bypass login controls, and access privileged information, or possibly conduct further attacks.
HCL BigFix Mobile / Modern Client Management Admin and Config UI passwords can be brute-forced. User should be locked out for multiple invalid attempts.
LibreNMS is an auto-discovering PHP/MySQL/SNMP based network monitoring which includes support for a wide range of network hardware and operating systems. In affected versions the login method has no rate limit. An attacker may be able to leverage this vulnerability to gain access to user accounts. This issue has been addressed in version 23.11.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
A vulnerability was discovered in GitLab versions before 13.1.10, 13.2.8 and 13.3.4. GitLab OAuth endpoint was vulnerable to brute-force attacks through a specific parameter.
An issue was discovered on Samsung mobile devices with P(9.0) and Q(10.0) (with TEEGRIS) software. Attackers can determine user credentials via a brute-force attack against the Gatekeeper trustlet. The Samsung ID is SVE-2020-16908 (May 2020).
OX App Suite 7.10.1 to 7.10.3 has improper input validation for rate limits with a crafted User-Agent header, spoofed vacation notices, and /apps/load memory consumption.
BAB TECHNOLOGIE GmbH eibPort V3 prior version 3.9.1 allow unauthenticated attackers to access uncontrolled the login service at /webif/SecurityModule in a brute force attack. The password could be weak and default username is known as 'admin'. This is usable and part of an attack chain to gain SSH root access.
An attacker can freely brute force username and password and can takeover any account. An attacker could easily guess user passwords and gain access to user and administrative accounts.
IBM Engineering Lifecycle Optimization 7.0.2 and 7.0.3 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 268755.
An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks.
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
In Sorcery before 0.15.0, there is a brute force vulnerability when using password authentication via Sorcery. The brute force protection submodule will prevent a brute force attack for the defined lockout period, but once expired, protection will not be re-enabled until a user or malicious actor logs in successfully. This does not affect users that do not use the built-in brute force protection submodule, nor users that use permanent account lockout. This has been patched in 0.15.0.
Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.
VMware Workspace ONE Access and Identity Manager, unintentionally provide a login interface on port 7443. A malicious actor with network access to port 7443 may attempt user enumeration or brute force the login endpoint, which may or may not be practical based on lockout policy configuration and password complexity for the target account.
Improper Restriction of Excessive Authentication Attempts in RDT400 in SICK APU allows an unprivileged remote attacker to guess the password via trial-and-error as the login attempts are not limited.
An issue was discovered on Samsung mobile devices with O(8.x), P(9.0), and Q(10.0) (Exynos7885, Exynos8895, and Exynos9810 chipsets) software. The Gatekeeper trustlet allows a brute-force attack on the screen lock password. The Samsung ID is SVE-2019-14575 (January 2020).
IBM Security Guardium 11.2 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 196314.
Vulnerability of brute-force attacks on the device authentication module.Successful exploitation of this vulnerability may affect service confidentiality.
Vulnerability of brute-force attacks on the device authentication module.Successful exploitation of this vulnerability may affect service confidentiality.
The Phonemes mode in Pwgen 2.06 generates predictable passwords, which makes it easier for context-dependent attackers to guess the password via a brute-force attack.
An issue in the user login box of LJCMS v1.11 allows attackers to hijack user accounts via brute force attacks.
Cryptocat before 2.0.42 has Group Chat ECC Private Key Generation Brute Force Weakness
A vulnerability classified as critical was found in Telecommunication Software SAMwin Contact Center Suite 5.1. This vulnerability affects the function passwordScramble in the library SAMwinLIBVB.dll of the component Password Handler. Incorrect implementation of a hashing function leads to predictable authentication possibilities. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to gain full access by brute force.
The maxView Storage Manager does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
Hikvision DVR DS-7204HGHI-F1 V4.0.1 build 180903 Web Version sends a different response for failed ISAPI/Security/sessionLogin/capabilities login attempts depending on whether the user account exists, which might make it easier to enumerate users. However, only about 4 or 5 failed logins are allowed.
Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX (formerly homeLYnk) which could allow an attacker to guess a password when brute force is used.
IBM Tivoli Key Lifecycle Manager 3.0.1 and 4.0 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 184156.
Trilium Notes is an open-source, cross-platform hierarchical note taking application with focus on building large personal knowledge bases. In versions below 0.97.0, a brute-force protection bypass in the initial sync seed retrieval endpoint allows unauthenticated attackers to guess the login password without triggering rate limiting. Trilium is a single-user app without a username requirement, and brute-force protection bypass makes exploitation much more feasible. Multiple features provided by Trilium (e.g. MFA, share notes, custom request handler) indicate that Trilium can be exposed to the internet. This is fixed in version 0.97.0.
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover when a brute force attack is performed on the account. Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0 and prior)
IBM Verify Gateway (IVG) 1.0.0 and 1.0.1 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 179478.
IBM Security Identity Governance and Intelligence 5.2.6 could allow an attacker to enumerate usernames to find valid login credentials which could be used to attempt further attacks against the system. IBM X-Force ID: 175336.
Password guessing limits could be bypassed when using LDAP authentication.
The Telnet service for Polycom ViewStation before 7.2.4 does not restrict the number of failed login attempts, which makes it easier for remote attackers to guess usernames and passwords via a brute force attack.
LimitLoginAttempts.php in the limit-login-attempts-reloaded plugin before 2.17.4 for WordPress allows a bypass of (per IP address) rate limits because the X-Forwarded-For header can be forged. When the plugin is configured to accept an arbitrary header for the client source IP address, a malicious user is not limited to perform a brute force attack, because the client IP header accepts any arbitrary string. When randomizing the header input, the login count does not ever reach the maximum allowed retries.
An issue was discovered in MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 through 2.6.2. The login pages bruteforce detection is disabled by default.
In Solstice Pod before 3.3.0 (or Open4.3), the Administrator password can be enumerated using brute-force attacks via the /Config/service/initModel?password= Solstice Open Control API because there is no complexity requirement (e.g., it might be all digits or all lowercase letters).
Compaq/Microcom 6000 Access Integrator does not disconnect a client after a certain number of failed login attempts, which allows remote attackers to guess usernames or passwords via a brute force attack.
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication.
Nextcloud Server provides data storage for Nextcloud, an open source cloud platform. In Nextcloud Server starting with 25.0.0 and prior to 25.09 and 26.04; as well as Nextcloud Enterprise Server starting with 22.0.0 and prior to 22.2.10.14, 23.0.12.9, 24.0.12.5, 25.0.9, and 26.0.4; missing protection allows an attacker to brute force passwords on the WebDAV API. Nextcloud Server 25.0.9 and 26.0.4 and Nextcloud Enterprise Server 22.2.10.14, 23.0.12.9, 24.0.12.5, 25.0.9, and 26.0.4 contain patches for this issue. No known workarounds are available.
The MEAC300-FNADE4 does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
The SMB server's login mechanism does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.
Moxa IKS and EDS do not implement sufficient measures to prevent multiple failed authentication attempts, which may allow an attacker to discover passwords via brute force attack.
IBM Robotic Process Automation with Automation Anywhere 11 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 161411.
IBM Cloud Pak System 2.3.1.1, 2.3.2.0, and 2.3.3.7 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 260733.
IBM Concert Software 1.0.5 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials.
IBM Security Directory Server 6.4.0 uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 165178.