A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.4). The affected applications accept unauthenticated file write messages. An unauthenticated remote attacker could write arbitrary files to the affected application's file system.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to disable front panel authentication via crafted HTTP requests.
A Broken Access Control vulnerability in the D-Link DSL-2680 web administration interface (Firmware EU_1.03) allows an attacker to enable or disable MAC address filtering by submitting a crafted Forms/WlanMacFilter_1 POST request without being authenticated on the admin interface.
A Broken Access Control vulnerability in the D-Link DSL-2680 web administration interface (Firmware EU_1.03) allows an attacker to change DNS servers without being authenticated on the admin interface by submitting a crafted Forms/dns_1 POST request.
A Broken Access Control vulnerability in the D-Link DSL-2680 web administration interface (Firmware EU_1.03) allows an attacker to download the configuration (binary file) settings by submitting a rom-0 GET request without being authenticated on the admin interface.
On Signify Philips Taolight Smart Wi-Fi Wiz Connected LED Bulb 9290022656 devices, an unprotected API lets remote users control the bulb's operation. Anyone can turn the bulb on or off, or change its color or brightness remotely. There is no authentication or encryption to use the control API. The only requirement is that the attacker have network access to the bulb.
Intelbras WRN240 devices do not require authentication to replace the firmware via a POST request to the incoming/Firmware.cfg URI.
includes/class-coming-soon-creator.php in the igniteup plugin through 3.4 for WordPress allows unauthenticated arbitrary file deletion.
The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.
search-exclude.php in the "Search Exclude" plugin before 1.2.4 for WordPress allows unauthenticated options changes.
Talend Data Catalog remote harvesting server before 8.0-20230413 contains a /upgrade endpoint that allows an unauthenticated WAR file to be deployed on the server. (A mitigation is that the remote harvesting server should be behind a firewall that only allows access to the Talend Data Catalog server.)
A security vulnerability exists in the Zingbox Inspector versions 1.280 and earlier, where authentication is not required when binding the Inspector instance to a different customer tenant.
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
Lack of authentication vulnerability. An unauthenticated local user is able to see through the cameras using the web server due to the lack of any form of authentication.
An external config control vulnerability exists in the OAS Engine SecureAddUser functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted series of network requests can lead to the creation of an OAS user account. An attacker can send a sequence of requests to trigger this vulnerability.
Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
ONLYOFFICE all versions as of 2021-11-08 is affected by Incorrect Access Control. An authentication bypass in the document editor allows attackers to edit documents without authentication.
ESPHome is a system to control the ESP8266/ESP32. Anyone with web_server enabled and HTTP basic auth configured on version 2021.9.1 or older is vulnerable to an issue in which `web_server` allows over-the-air (OTA) updates without checking user defined basic auth username & password. This issue is patched in version 2021.9.2. As a workaround, one may disable or remove `web_server`.
A vulnerability, which was classified as problematic, was found in TOTOLINK A3700R 9.1.2u.5822_B20200513. Affected is an unknown function of the file /wizard.html of the component Password Reset Handler. The manipulation leads to improper access controls. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272568. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to version 1.10.7, FreeSWITCH does not authenticate SIP MESSAGE requests, leading to spam and message spoofing. By default, SIP requests of the type MESSAGE (RFC 3428) are not authenticated in the affected versions of FreeSWITCH. MESSAGE requests are relayed to SIP user agents registered with the FreeSWITCH server without requiring any authentication. Although this behaviour can be changed by setting the `auth-messages` parameter to `true`, it is not the default setting. Abuse of this security issue allows attackers to send SIP MESSAGE messages to any SIP user agent that is registered with the server without requiring authentication. Additionally, since no authentication is required, chat messages can be spoofed to appear to come from trusted entities. Therefore, abuse can lead to spam and enable social engineering, phishing and similar attacks. This issue is patched in version 1.10.7. Maintainers recommend that this SIP message type is authenticated by default so that FreeSWITCH administrators do not need to be explicitly set the `auth-messages` parameter. When following such a recommendation, a new parameter can be introduced to explicitly disable authentication.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
An issue was discovered in Couchbase Server before 7.0.4. The Index Service does not enforce authentication for TCP/TLS servers.
IBM Guardium Data Encryption (GDE) 3.0.0.2 and 4.0.0.4 does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.