cPanel before 60.0.25 does not use TLS for HTTP POSTs to listinput.cpanel.net (SEC-192).
Directory traversal vulnerability in frontend/x3/stats/lastvisit.html in cPanel allows remote attackers to read arbitrary files via a .. (dot dot) in the domain parameter.
cPanel before 11.52.0.13 does not prevent arbitrary file-read operations via get_information_for_applications (CPANEL-1221).
Directory traversal vulnerability in index.php in Fantastico, as used with cPanel 11.x, allows remote attackers to read arbitrary files via a .. (dot dot) in the sup3r parameter.
Absolute path traversal vulnerability in the Disk Usage module (frontend/x/diskusage/index.html) in cPanel 11.18.3 allows remote attackers to list arbitrary directories via the showtree parameter.
cPanel before 55.9999.141 mishandles username-based blocking for PRE requests in cPHulkd (SEC-104).
In cPanel before 88.0.3, an insecure auth policy API key is used by Dovecot on a templated VM (SEC-550).
In cPanel before 88.0.3, an insecure SRS secret is used on a templated VM (SEC-552).
cPanel before 88.0.3, upon an upgrade, establishes predictable PowerDNS API keys (SEC-561).
In cPanel before 88.0.3, insecure RNDC credentials are used for BIND on a templated VM (SEC-549).
In cPanel before 88.0.3, insecure chkservd test credentials are used on a templated VM (SEC-554).
cPanel before 64.0.21 allows attackers to read a user's crontab file during a short time interval upon a cPAddon upgrade (SEC-257).
cPanel 9.4.1-RELEASE-64 follows hard links, which allows local users to (1) read arbitrary files via the backup feature or (2) chown arbitrary files via the .htaccess file when Front Page extensions are enabled or disabled.
cPanel before 64.0.21 allows certain file-read operations via a Serverinfo_manpage API call (SEC-252).
cPanel before 88.0.3 has weak permissions (world readable) for the proxy subdomains log file (SEC-558).
Leech Protect in cPanel before 62.0.4 does not protect certain directories (SEC-205).
Weak Password Requirements vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to access to the module via FTP by dictionary attack or password sniffing.
File Browser provides a file managing interface within a specified directory and it can be used to upload, delete, preview, rename and edit files. Prior to version 2.34.1, a missing password policy and brute-force protection makes the authentication process insecure. Attackers could mount a brute-force attack to retrieve the passwords of all accounts in a given instance. This issue has been patched in version 2.34.1.
IBM Security Identity Manager 6.0.0 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 153628.
IBM Security Privileged Identity Manager Virtual Appliance 2.2.1 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 145236.
IBM Security Guardium Big Data Intelligence (SonarG) 3.1 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 137772.
A vulnerability in the Gleez CMS 1.2.0 login page could allow an unauthenticated, remote attacker to perform multiple user enumerations, which can further help an attacker to perform login attempts in excess of the configured login attempt limit. The vulnerability is due to insufficient server-side access control and login attempt limit enforcement. An attacker could exploit this vulnerability by sending modified login attempts to the Portal login page. An exploit could allow the attacker to identify existing users and perform brute-force password attacks on the Portal, as demonstrated by navigating to the user/4 URI.
Open Dental before version 18.4 installs a mysql database and uses the default credentials of "root" with a blank password. This allows anyone on the network with access to the server to access all database information.
The telnet administrator service running on port 650 on Gigaset DX600A v41.00-175 devices does not implement any lockout or throttling functionality. This situation (together with the weak password policy that forces a 4-digit password) allows remote attackers to easily obtain administrative access via brute-force attacks.
A weak password requirement vulnerability exists in the Create New User function of MintHCM RELEASE 3.0.8, which could lead an attacker to easier password brute-forcing.
An issue was discovered in Znuny before 7.1.5. When generating a support bundle, not all passwords are masked.
An issue was discovered in Optimizely EPiServer.CMS.Core before 12.32.0. A medium-severity vulnerability exists in the CMS due to insufficient enforcement of password complexity requirements. The application permits users to set passwords with a minimum length of 6 characters, lacking adequate complexity to resist modern attack techniques such as password spraying or offline password cracking.
IBM Security Guardium 11.2 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 196279.
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
IBM Sterling Order Management 10.0 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 229698.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, weak password requirements may allow an attacker to gain access using brute force.
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Insufficient password requirements for the MGate web application may allow an attacker to gain access by brute-forcing account passwords.
A compliance problem was found in the Red Hat OpenShift Container Platform. Red Hat discovered that, when FIPS mode was enabled, not all of the cryptographic modules in use were FIPS-validated.
A CWE-521: Weak Password Requirements vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to compromise a user account.
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static account username/password for access control. This password can be generated via a binary included in the firmware, after ascertaining the MAC address of the IDU's base Ethernet interface, and adding the string DEVICE_MANUFACTURER='Wistron_NeWeb_Corp.' to /etc/device_info to replicate the host environment. This occurs in /etc/init.d/wnc_factoryssidkeypwd (IDU).
Use of weak credentials exists in Seiko Solutions SkyBridge and SkySpider series, which may allow a remote unauthenticated attacker to decrypt password for the WebUI of the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, and SkySpider MB-R210 firmware Ver. 1.01.00 and earlier.
Verizon 4G LTE Network Extender GA4.38 - V0.4.038.2131 utilizes a weak default admin password generation algorithm which generates passwords that are accessible to unauthenticated attackers via the webUI login page.
Dell PowerScale OneFS versions 8.2.0.x through 9.3.0.x, contain a weak password requirement vulnerability. An administrator may create an account with no password. A remote attacker may potentially exploit this leading to a user account compromise.
The National Payments Corporation of India BHIM application 1.3 for Android relies on a four-digit passcode, which makes it easier for attackers to obtain access.
Weak Password Requirements in GitHub repository kromitgmbh/titra prior to 0.78.1.
A default username and password for an administrator account was discovered in ZKTeco ZKTime 10.0 through 11.1.0, builds 20180901, 20190510.1, 20200309.3, 20200930, 20201231, and 20210220.
HCL iNotes is susceptible to a Broken Password Strength Checks vulnerability. Custom password policies are not enforced on certain iNotes forms which could allow users to set weak passwords, leading to easier cracking.
The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords.
There are no requirements for setting a complex password for PiiGAB M-Bus, which could contribute to a successful brute force attack if the password is inline with recommended password guidelines.
etcd before versions 3.3.23 and 3.4.10 does not perform any password length validation, which allows for very short passwords, such as those with a length of one. This may allow an attacker to guess or brute-force users' passwords with little computational effort.
EnterpriseDB EDB Postgres Advanced Server (EPAS) before 14.6.0 logs unredacted passwords in situations where optional parameters are used with CREATE/ALTER USER/GROUP/ROLE, and redacting was configured with edb_filter_log.redact_password_commands. The fixed versions are 10.23.33, 11.18.29, 12.13.17, 13.9.13, and 14.6.0.
In Daybyday CRM, versions 1.1 through 2.2.0 enforce weak password requirements in the user update functionality. A user with privileges to update his password could change it to a weak password, such as those with a length of a single character. This may allow an attacker to brute-force users’ passwords with minimal to no computational effort.
In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.
IBM Security Guardium Data Encryption (GDE) 3.0.0.2 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 171929.
IBM Security Key Lifecycle Manager 3.0 and 3.0.1 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 166626.