An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of characters. NOTE: the vendor reports that the 12-character limit provides "a very high security standard." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Insufficient password requirements for the MGate web application may allow an attacker to gain access by brute-forcing account passwords.
Weak Password Requirements in GitHub repository thorsten/phpmyfaq prior to 3.1.10.
In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.
IBM Intelligent Operations Center V5.1.0 - V5.2.0, IBM Intelligent Operations Center for Emergency Management V5.1.0 - V5.1.0.6, and IBM Water Operations for Waternamics V5.1.0 - V5.2.1.1 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 161201.
IBM PureApplication System 2.2.3.0 through 2.2.5.3 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 159417.
IBM Security Guardium 10.0, 10.0.1, 10.1, 10.1.2, 10.1.3, 10.1.4, and 10.5 Database Activity Monitor does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 132610.
In Gradle Enterprise before 2023.1, a remote attacker may be able to gain access to a new installation (in certain installation scenarios) because of a non-unique initial system user password. Although this password must be changed upon the first login, it is possible that an attacker logs in before the legitimate administrator logs in.
An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. Once access is gained either by default, common, or cracked passwords, the video recordings (containing sensitive routes, conversations, and footage) are open for downloading by creating a socket to command port 7777, and then downloading video via port 7778 and audio via port 7779.
Weak password requirements in OpenC3 COSMOS v6.0.0 allow attackers to bypass authentication via a brute force attack.
Victure RX1800 EN_V1.0.0_r12_110933 was discovered to utilize a weak default password which includes the last 8 digits of the Mac address.
IBM BigFix Compliance (TEMA SUAv1 SCA SCM) 1.9.70 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 123671.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.843 Application 20.0.1923 allows Weak Password Encryption / Encoding OVE-20230524-0007.
Weak password requirements issue exists in CHOCO TEI WATCHER mini (IB-MCT001) all versions. If this issue is exploited, a brute-force attack may allow an attacker unauthorized access and login.
In cPanel before 88.0.3, an insecure site password is used for Mailman on a templated VM (SEC-551).
Weak Password Policy.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.
Missing Initial Password Change.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.
MLflow Weak Password Requirements Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of MLflow. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of passwords. The issue results from weak password requirements. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26916.
Trend Micro Mobile Security for Android (Consumer) versions 10.3.1 and below on Android 8.0+ has an issue in which an attacker could bypass the product's App Password Protection feature.
NeuVector 3.1 when configured to allow authentication via Active Directory, does not enforce non-empty passwords which allows an attacker with access to the Neuvector portal to authenticate as any valid LDAP user by providing a valid username and an empty password (provided that the active directory server has not been configured to reject empty passwords).
Jfrog Artifactory uses default passwords (such as "password") for administrative accounts and does not require users to change them. This may allow unauthorized network-based attackers to completely compromise of Jfrog Artifactory. This issue affects Jfrog Artifactory versions prior to 6.17.0.
IBM Cognos Analytics 11.1.7 and 11.2.0 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 196339.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
IBM Tivoli Key Lifecycle Manager does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 184181.
In IQrouter through 3.3.1, the Lua function reset_password in the web-panel allows remote attackers to change the root password arbitrarily. Note: The vendor claims that this vulnerability can only occur on a brand-new network that, after initiating the forced initial configuration (which has a required step for setting a secure password on the system), makes this CVE invalid. This vulnerability is “true for any unconfigured release of OpenWRT, and true of many other new Linux distros prior to being configured for the first time”
I-doit pro 25 and below and I-doit open 25 and below employ weak password requirements for Administrator account creation. Attackers are able to easily guess users' passwords via a bruteforce attack.
HCL Compass is vulnerable to insecure password requirements. An attacker could easily guess the password and gain access to user accounts.
There are no requirements for setting a complex password for PiiGAB M-Bus, which could contribute to a successful brute force attack if the password is inline with recommended password guidelines.
Weak Password Requirements vulnerability in Apache Software Foundation Apache InLong.This issue affects Apache InLong: from 1.1.0 through 1.6.0. When users change their password to a simple password (with any character or symbol), attackers can easily guess the user's password and access the account. Users are advised to upgrade to Apache InLong's 1.7.0 or cherry-pick https://github.com/apache/inlong/pull/7805 https://github.com/apache/inlong/pull/7805 to solve it.
Cloudexplorer-lite is an open source cloud software stack. Weak passwords can be easily guessed and are an easy target for brute force attacks. This can lead to an authentication system failure and compromise system security. Versions of cloudexplorer-lite prior to 1.2.0 did not enforce strong passwords. This vulnerability has been fixed in version 1.2.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
Weak Password Requirements in GitHub repository modoboa/modoboa prior to 2.1.0.
Beijing Zed-3 Technologies Co.,Ltd VoIP simpliclty ASG 8.5.0.17807 (20181130-16:12) has a Weak password vulnerability.
IBM Security Guardium Data Encryption (GDE) 3.0.0.2 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 171929.
RuoYi v3.8.3 has a Weak password vulnerability in the management system.
Weak Password Requirements in GitHub repository thorsten/phpmyfaq prior to 3.1.8.
Renato v0.17.0 employs weak password complexity requirements, allowing attackers to crack user passwords via brute-force attacks.
An issue discovered in Pfsense CE version 2.6.0 allows attackers to compromise user accounts via weak password requirements.
Weak Password Requirements in GitHub repository ikus060/minarca prior to 4.2.2.
An issue was discovered in Infiray IRAY-A8Z3 1.0.957. There is a blank root password for TELNET by default.
Verizon 4G LTE Network Extender GA4.38 - V0.4.038.2131 utilizes a weak default admin password generation algorithm which generates passwords that are accessible to unauthenticated attackers via the webUI login page.
Dell PowerScale OneFS versions 8.2.0.x through 9.3.0.x, contain a weak password requirement vulnerability. An administrator may create an account with no password. A remote attacker may potentially exploit this leading to a user account compromise.
Weak Password Requirements in GitHub repository notrinos/notrinoserp prior to 0.7.
etcd before versions 3.3.23 and 3.4.10 does not perform any password length validation, which allows for very short passwords, such as those with a length of one. This may allow an attacker to guess or brute-force users' passwords with little computational effort.
An issue was discovered on Connectize AC21000 G6 641.139.1.1256 allows attackers to gain escalated privileges on the device via poor credential management.
IBM Security Identity Manager 6.0.0 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 153628.
Mealie 1.0.0beta3 employs weak password requirements which allows attackers to potentially gain unauthorized access to the application via brute-force attacks.
Weak default root user credentials allow remote attackers to easily obtain OS superuser privileges over the open TCP port for SSH.
The National Payments Corporation of India BHIM application 1.3 for Android relies on a four-digit passcode, which makes it easier for attackers to obtain access.
Weak Password Requirements in GitHub repository polonel/trudesk prior to 1.2.2.