A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service.
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly assign permissions to critical ressources. This could allow a non-privileged local attacker to interact with the backupmanager service.
A vulnerability has been identified in JT2Go (All versions < V13.1.0.2), Teamcenter Visualization (All versions < V13.1.0.2). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information. (ZDI-CAN-12042)
A vulnerability has been identified in DIGSI 4 (All versions < V4.94 SP1 HF 1). Several folders in the %PATH% are writeable by normal users. As these folders are included in the search for dlls, an attacker could place dlls there with code executed by SYSTEM.
A vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.4). The software insecurely loads libraries which makes it vulnerable to DLL hijacking. Successful exploitation by a local attacker could lead to a takeover of the system where the software is installed.
Improper input validation in BIOS firmware for some Intel(R) Processors may allow an authenticated user to potentially enable escalation of privilege via local access.
Improper buffer restrictions in BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The directory of service executables of the affected application could allow a local attacker to include arbitrary commands that are executed with SYSTEM privileges when the system restarts.
A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4). The lmgrd service of the affected application is executed with local SYSTEM privileges on the server while its configuration can be modified by local users. The vulnerability could allow a local authenticated attacker to execute arbitrary commands on the server with local SYSTEM privileges.
A vulnerability has been identified in Spectrum Power 7 (All versions < V23Q3). The affected product assigns improper access rights to the update script. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
A vulnerability has been identified in SICAM TOOLBOX II (All versions < V07.10). The affected application's database service is executed as `NT AUTHORITY\SYSTEM`. This could allow a local attacker to execute operating system commands with elevated privileges.
A local authentication bypass vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x: 6.5.4.15 and below; Aruba Instant 8.3.x: 8.3.0.11 and below; Aruba Instant 8.4.x: 8.4.0.5 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Instant 8.6.x: 8.6.0.2 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11 (only with activated debug support)). The affected devices contain a hard-coded ID in the SSH `authorized_keys` configuration file. An attacker with knowledge of the corresponding private key could login to the device via SSH. Only devices with activated debug support are affected.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with local access to the MS3000 Server and a low privileged user account could gain root privileges by manipulating specific files in the local file system. This vulnerability is independent from CVE-2019-18308. Please note that an attacker needs to have local access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in TIA Administrator (All versions < V3.0.6). The affected application allows low-privileged users to trigger installations by overwriting cache files and modifying the downloads path. This would allow an attacker to escalate privilege and exceute arbitrary code.
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
OpenSSH 7.7 through 7.9 and 8.x before 8.1, when compiled with an experimental key type, has a pre-authentication integer overflow if a client or server is configured to use a crafted XMSS key. This leads to memory corruption and local code execution because of an error in the XMSS key parsing algorithm. NOTE: the XMSS implementation is considered experimental in all released OpenSSH versions, and there is no supported way to enable it when building portable OpenSSH.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with local access to the MS3000 Server and a low privileged user account could gain root privileges by manipulating specific files in the local file system. This vulnerability is independent from CVE-2019-18309. Please note that an attacker needs to have local access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access.
A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
A vulnerability has been identified in SIPORT (All versions < V3.4.0). The affected application improperly assigns file permissions to installation folders. This could allow a local attacker with an unprivileged account to override or modify the service executables and subsequently gain elevated privileges.
A flaw was found in the way the "flags" member of the new pipe buffer structure was lacking proper initialization in copy_page_to_iter_pipe and push_pipe functions in the Linux kernel and could thus contain stale values. An unprivileged local user could use this flaw to write to pages in the page cache backed by read only files and as such escalate their privileges on the system.
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation.
A vulnerability has been identified in Siemens Software Center (All versions < V3.0). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server.
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app's authentication mechanism under certain conditions.
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.
A vulnerability has been identified in Unicam FX (All versions). The windows installer agent used in affected product contains incorrect use of privileged APIs that trigger the Windows Console Host (conhost.exe) as a child process with SYSTEM privileges. This could be exploited by an attacker to perform a local privilege escalation attack.
A vulnerability has been identified in SICAM TOOLBOX II (All versions < V07.10). Affected applications do not properly set permissions for product folders. This could allow an authenticated attacker with low privileges to replace DLLs and conduct a privilege escalation.
An authenticated command injection vulnerability exists in the Aruba InstantOS and ArubaOS 10 command line interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InstantOS that address this security vulnerability.
A vulnerability has been identified in SENTRON powermanager V3 (All versions). The affected application assigns improper access rights to a specific folder containing configuration files. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V2.85.44), SiPass integrated ACC-AP (All versions < V2.85.43). Affected devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges.
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges.
Improper initialization in subsystem for Intel(R) CSME versions before12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25, Intel(R) TXE versions before 4.0.30 Intel(R) SPS versions before E3_05.01.04.200 may allow a privileged user to potentially enable escalation of privilege via local access.
curl 7.20.0 through 7.70.0 is vulnerable to improper restriction of names for files and other resources that can lead too overwriting a local file when the -J flag is used.
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.
A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0.8). The application does not properly validate the users' privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing.
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions), Teamcenter V13.2 (All versions < V13.2.0.8), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash.
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20304)
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20299, ZDI-CAN-20346)
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20300)
Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are vulnerable to multiple out-of-bounds write issues while processing project files, which may allow an attacker to execute arbitrary code.
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains a memory corruption vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20303, ZDI-CAN-20348)
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application is vulnerable to stack-based buffer while parsing specially crafted SPP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-20449)
A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19818)