Harmonic NSG 9000 devices have a default password of nsgadmin for the admin account, a default password of nsgguest for the guest account, and a default password of nsgconfig for the config account.
The demo feature in Oracle GlassFish Open Source Edition 5.0 has TCP port 7676 open by default with a password of admin for the admin account. This allows remote attackers to obtain potentially sensitive information, perform database operations, or manipulate the demo via a JMX RMI session, aka a "jmx_rmi remote monitoring and control problem." NOTE: this is not an Oracle supported product.
SV3C L-SERIES HD CAMERA V2.3.4.2103-S50-NTD-B20170508B and V2.3.4.2103-S50-NTD-B20170823B devices have a Hard-coded Password.
Emerson DeltaV Smart Switch Command Center application, available in versions 11.3.x and 12.3.1, was unable to change the DeltaV Smart Switches’ management password upon commissioning. Emerson released patches for DeltaV workstations to address this issue, and the patches can be downloaded from Emerson’s Guardian Support Portal. Please refer to the DeltaV Security Notification DSN19003 (KBA NK-1900-0808) for more information about this issue. DeltaV versions 13.3 and higher use the Network Device Command Center application to manage DeltaV Smart Switches, and this newer application is not impacted by this issue. After patching the Smart Switch Command Center, users are required to either commission the DeltaV Smart Switches or change password using the tool.
Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
GateManager versions prior to 9.2c, The affected product contains a hard-coded credential for telnet, allowing an unprivileged attacker to execute commands as root.
A hard-coded password vulnerability was discovered in vApp Manager which is embedded in Dell EMC Unisphere for VMAX, Dell EMC Solutions Enabler, Dell EMC VASA Virtual Appliances, and Dell EMC VMAX Embedded Management (eManagement): Dell EMC Unisphere for VMAX Virtual Appliance versions prior to 8.4.0.18, Dell EMC Solutions Enabler Virtual Appliance versions prior to 8.4.0.21, Dell EMC VASA Virtual Appliance versions prior to 8.4.0.514, and Dell EMC VMAX Embedded Management (eManagement) versions prior to and including 1.4 (Enginuity Release 5977.1125.1125 and earlier). They contain an undocumented default account (smc) with a hard-coded password that may be used with certain web servlets. A remote attacker with the knowledge of the hard-coded password and the message format may use vulnerable servlets to gain unauthorized access to the system. Note: This account cannot be used to log in via the web user interface.
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
TRENDnet TEW-823DRU devices with firmware before 1.00b36 have a hardcoded password of kcodeskcodes for the root account, which makes it easier for remote attackers to obtain access via an FTP session.
A vulnerability in Cisco Video Surveillance Manager (VSM) Software running on certain Cisco Connected Safety and Security Unified Computing System (UCS) platforms could allow an unauthenticated, remote attacker to log in to an affected system by using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, default, static user credentials for the root account of the affected software on certain systems. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
An issue was discovered on Intelbras NCLOUD 300 1.0 devices. /cgi-bin/ExportSettings.sh, /goform/updateWPS, /goform/RebootSystem, and /goform/vpnBasicSettings do not require authentication. For example, when an HTTP POST request is made to /cgi-bin/ExportSettings.sh, the username, password, and other details are retrieved.
Softing FG-100 PB PROFIBUS firmware version FG-x00-PB_V2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session.
Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.
Battelle V2I Hub 2.5.1 contains hard-coded credentials for the administrative account. An attacker could exploit this vulnerability to log in as an admin on any installation and gain unauthorized access to the system.
Telesquare SDT-CS3B1 and SDT-CW3B1 devices through 1.2.0 have a default factory account. Remote attackers can obtain access to the device via TELNET using a hardcoded account.
The MySQL server in Juniper Networks Junos Space before 13.3R1.8 has an unspecified account with a hardcoded password, which allows remote attackers to obtain sensitive information and consequently obtain administrative control by leveraging database access.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
BB-ESWGP506-2SFP-T versions 1.01.09 and prior is vulnerable due to the use of hard-coded credentials, which may allow an attacker to gain unauthorized access and permit the execution of arbitrary code on the BB-ESWGP506-2SFP-T (versions 1.01.01 and prior).
Juniper Networks Contrail Service Orchestrator versions prior to 4.0.0 use hardcoded cryptographic certificates and keys in some cases, which may allow network based attackers to gain unauthorized access to services.
A vulnerability in Cisco IOS XE Software could allow an unauthenticated, remote attacker to log in to a device running an affected release of Cisco IOS XE Software with the default username and password that are used at initial boot, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with privilege level 15 that has a default username and password. An attacker could exploit this vulnerability by using this account to remotely connect to an affected device. A successful exploit could allow the attacker to log in to the device with privilege level 15 access. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS XE Software Release 16.x. This vulnerability does not affect Cisco IOS XE Software releases prior to Release 16.x. Cisco Bug IDs: CSCve89880.
IZON IP 2.0.2: hard-coded password vulnerability
A vulnerability in Cisco Digital Network Architecture (DNA) Center could allow an unauthenticated, remote attacker to log in to an affected system by using an administrative account that has default, static user credentials. The vulnerability is due to the presence of undocumented, static user credentials for the default administrative account for the affected software. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands with root privileges. This vulnerability affects all releases of Cisco DNA Center Software prior to Release 1.1.3. Cisco Bug IDs: CSCvh98929.
A vulnerability in the Cluster Manager of Cisco Policy Suite before 18.2.0 could allow an unauthenticated, remote attacker to log in to an affected system using the root account, which has default, static user credentials. The vulnerability is due to the presence of undocumented, static user credentials for the root account. An attacker could exploit this vulnerability by using the account to log in to an affected system. An exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user. Cisco Bug IDs: CSCvh02680.
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom telnet daemon as a part of the busybox and retrieves the password from the shadow file using the function getspnam at address 0x00053894. Then performs a crypt operation on the password retrieved from the user at address 0x000538E0 and performs a strcmp at address 0x00053908 to check if the password is correct or incorrect. However, the /etc/shadow file is a part of CRAM-FS filesystem which means that the user cannot change the password and hence a hardcoded hash in /etc/shadow is used to match the credentials provided by the user. This is a salted hash of the string "admin" and hence it acts as a password to the device which cannot be changed as the whole filesystem is read only.
An issue was discovered on the ENTTEC Datagate MK2, Storm 24, Pixelator, and E-Streamer MK2 with firmware 70044_update_05032019-482. They include a hard-coded SSH backdoor for remote SSH and SCP access as the root user. A command in the relocate and relocate_revB scripts copies the hardcoded key to the root user's authorized_keys file, enabling anyone with the associated private key to gain remote root access to all affected products.
On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not).
On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root"). The attacker can make a user that is connected to the repeater click on a malicious link that will log into the telnet and will infect the device with malicious code.
Grandstream GXV3501, GXV3504, GXV3601, GXV3601HD/LL, GXV3611HD/LL, GXV3615W/P, GXV3651FHD, GXV3662HD, GXV3615WP_HD, GXV3500, and possibly other camera models with firmware 1.0.4.11, have a hardcoded account "!#/" with the same password, which makes it easier for remote attackers to obtain access via a TELNET session.
A vulnerability in the Out-of-Band Access Point (AP) Image Download, the Clean Air Spectral Recording, and the client debug bundles features of Cisco IOS XE Software for Wireless LAN Controllers (WLCs) could allow an unauthenticated, remote attacker to upload arbitrary files to an affected system. This vulnerability is due to the presence of a hard-coded JSON Web Token (JWT) on an affected system. An attacker could exploit this vulnerability by sending crafted HTTPS requests to the AP file upload interface. A successful exploit could allow the attacker to upload files, perform path traversal, and execute arbitrary commands with root privileges.
A vulnerability in Cisco Unified Communications Manager (Unified CM) and Cisco Unified Communications Manager Session Management Edition (Unified CM SME) could allow an unauthenticated, remote attacker to log in to an affected device using the root account, which has default, static credentials that cannot be changed or deleted. This vulnerability is due to the presence of static user credentials for the root account that are reserved for use during development. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
This issue is not applicable to NFX NextGen Software. On NFX Series devices the use of Hard-coded Credentials in Juniper Networks Junos OS allows an attacker to take over any instance of an NFX deployment. This issue is only exploitable through administrative interfaces. This issue affects: Juniper Networks Junos OS versions prior to 19.1R1 on NFX Series. No other platforms besides NFX Series devices are affected.
Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET.
EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system.
TimeTools SC7105 1.0.007, SC9205 1.0.007, SC9705 1.0.007, SR7110 1.0.007, SR9210 1.0.007, SR9750 1.0.007, SR9850 1.0.007, T100 1.0.003, T300 1.0.003, and T550 1.0.003 devices allow remote attackers to bypass authentication by placing t3axs=TiMEtOOlsj7G3xMm52wB in a t3.cgi request, aka a "hardcoded cookie."
The Carlo Gavazzi EOS-Box stores hard-coded passwords in the PHP file of the device. By using the hard-coded passwords, attackers can log into the device with administrative privileges. This could allow the attacker to have unauthorized access.
An issue was discovered in Polycom Web Management Interface G3/HDX 8000 HD with Durango 2.6.0 4740 software and embedded Polycom Linux Development Platform 2.14.g3. It has a blank administrative password by default, and can be successfully used without setting this password.
A vulnerability classified as critical has been found in TOTOLINK T10 AC1200 4.1.8cu.5207. Affected is an unknown function of the file /squashfs-root/web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to hard-coded credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in TOTOLINK CP450 4.1.0cu.747_B20191224. It has been classified as critical. This affects an unknown part of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
IBM XIV Storage System 2810-A14 and 2812-A14 devices before level 10.2.4.e-2 and 2810-114 and 2812-114 devices before level 11.1.1 have hardcoded passwords for unspecified accounts, which allows remote attackers to gain user access via unknown vectors. IBM X-Force ID: 75041.
The Intellian Aptus application 1.0.2 for Android has a hardcoded password of intellian for the masteruser FTP account.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Quest Foglight Evolve 9.0.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the __service__ user account. The product contains a hard-coded password for this account. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-9553.
EMV DiskXtender 6.20.060 has a hard-coded login and password, which allows remote attackers to bypass authentication via the RPC interface.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
Proietti Tech srl Planet Time Enterprise 4.2.0.1,4.2.0.0,4.1.0.0,4.0.0.0,3.3.1.0,3.3.0.0 is vulnerable to Remote code execution via the Viewstate parameter.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
The SSH server in Cisco Unified IP Phone 7906G, 7911G, 7941G, 7961G, 7970G, and 7971G, with firmware 8.0(4)SR1 and earlier, uses a hard-coded username and password, which allows remote attackers to access the device.
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could allow unauthenticated remote attackers to gain full access to a device, if they are in possession of these credentials and if the ssh service is enabled (e.g., by exploitation of CVE-2024-41793).
Dell EMC Networking S4100 and S5200 Series Switches manufactured prior to February 2020 contain a hardcoded credential vulnerability. A remote unauthenticated malicious user could exploit this vulnerability and gain administrative privileges.
Hardcoded admin token in SoundBar apps in Linkplay SDK 1.00 allows remote attackers to gain admin privilege access in linkplay antifactory
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)