TOTOLINK A3100R V4.1.2cu.5050_B20200504 and V4.1.2cu.5247_B20211129 were discovered to contain a hard coded password for the telnet service stored in the component /web_cste/cgi-bin/product.ini.
Certain builds of NEC SV9100 software could allow an unauthenticated, remote attacker to log into a device running an affected release with a hardcoded username and password, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with manufacturer privilege level. An attacker could exploit this vulnerability by using this account to remotely log into an affected device. A successful exploit could allow the attacker to log into the device with manufacturer level access. This vulnerability affects SV9100 PBXes that are running software release 6.0 or higher. This vulnerability does not affect SV9100 software releases prior to 6.0.
TOTOLINK A3100R V4.1.2cu.5050_B20200504 and V4.1.2cu.5247_B20211129 were discovered to contain a hard coded password for root stored in the component /etc/shadow.sample.
A vulnerability in the REST API of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. The vulnerability exists because different installations share a static encryption key. An attacker could exploit this vulnerability by using the static key to craft a valid session token. A successful exploit could allow the attacker to perform arbitrary actions through the REST API with administrative privileges.
The Integrated User Firewall (UserFW) feature was introduced in Junos OS version 12.1X47-D10 on the Juniper SRX Series devices to provide simple integration of user profiles on top of the existing firewall polices. As part of an internal security review of the UserFW services authentication API, hardcoded credentials were identified and removed which can impact both the SRX Series device, and potentially LDAP and Active Directory integrated points. An attacker may be able to completely compromise SRX Series devices, as well as Active Directory servers and services. When Active Directory is compromised, it may allow access to user credentials, workstations, servers performing other functions such as email, database, etc. Inter-Forest Active Directory deployments may also be at risk as the attacker may gain full administrative control over one or more Active Directories depending on the credentials supplied by the administrator of the AD domains and SRX devices performing integrated authentication of users, groups and devices. To identify if your device is potentially vulnerable to exploitation, check to see if the service is operating; from CLI review the following output: root@SRX-Firewall# run show services user-identification active-directory-access domain-controller status extensive A result of "Status: Connected" will indicate that the service is active on the device. To evaluate if user authentication is occurring through the device: root@SRX-Firewall# run show services user-identification active-directory-access active-directory-authentication-table all Next review the results to see if valid users and groups are returned. e.g. Domain: juniperlab.com Total entries: 3 Source IP Username groups state 172.16.26.1 administrator Valid 192.168.26.2 engg01 engineers Valid 192.168.26.3 guest01 guests Valid Domain: NULL Total entries: 8 Source IP Username groups state 192.168.26.4 Invalid 192.168.26.5 Invalid This will also indicate that Valid users and groups are authenticating through the device. Affected releases are Juniper Networks Junos OS 12.3X48 from 12.3X48-D30 and prior to 12.3X48-D35 on SRX series; 15.1X49 from 15.1X49-D40 and prior to 15.1X49-D50 on SRX series. Devices on any version of Junos OS 12.1X46, or 12.1X47 are unaffected by this issue.
D-Link DSR-500N version 1.02 contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file.If an attacker succeeds in recovering the cleartext password of the identified hash value, he will be able to log in via SSH or Telnet and thus gain access to the underlying embedded Linux operating system on the device. Fixed in version 2.12/2. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
An authentication bypass vulnerability exists in the device password generation functionality of Swift Sensors Gateway SG3-1010. A specially-crafted network request can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.
A vulnerability in the key-based SSH authentication mechanism of Cisco Policy Suite could allow an unauthenticated, remote attacker to log in to an affected system as the root user. This vulnerability is due to the re-use of static SSH keys across installations. An attacker could exploit this vulnerability by extracting a key from a system under their control. A successful exploit could allow the attacker to log in to an affected system as the root user.
An issue was discovered on Geeni GNC-CW013 doorbell 1.8.1 devices. A vulnerability exists in the Telnet service that allows a remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password.
The firmware of the PLANET Technology Corp NVR-915 and NVR-1615 before 2020-10-28 embeds default credentials for root access via telnet. By exposing telnet on the Internet, remote root access on the device is possible. NOTE: This vulnerability only affects products that are no longer supported by the maintainer
Ruckus vRioT through 1.5.1.0.21 has an API backdoor that is hardcoded into validate_token.py. An unauthenticated attacker can interact with the service API by using a backdoor value as the Authorization header.
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
The factory configuration for vMX installations, as shipped, includes default credentials for the root account. Without proper modification of these default credentials by the administrator, an attacker could exploit these credentials and access the vMX instance without authorization. This issue affects Juniper Networks Junos OS: 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on vMX; 17.2 versions prior to 17.2R3-S3 on vMX; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on vMX; 17.4 versions prior to 17.4R2-S9, 17.4R3 on vMX; 18.1 versions prior to 18.1R3-S9 on vMX; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3 on vMX; 18.2X75 versions prior to 18.2X75-D420, 18.2X75-D60 on vMX; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3-S1 on vMX; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on vMX; 19.1 versions prior to 19.1R1-S4, 19.1R2, 19.1R3 on vMX; 19.2 versions prior to 19.2R1-S3, 19.2R2 on vMX; 19.3 versions prior to 19.3R1-S1, 19.3R2 on vMX.
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The Dropbear SSH daemon has been modified to accept an alternate hard-coded path to a public key that allows root access. This key is stored in a /rom location that cannot be modified by the device owner.
The Le-yan dental management system contains a hard-coded credentials vulnerability in the web page source code, which allows an unauthenticated remote attacker to acquire administrator’s privilege and control the system or disrupt service.
An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.
OpsRamp Gateway before 7.0.0 has a backdoor account vadmin with the password 9vt@f3Vt that allows root SSH access to the server. This issue has been resolved in OpsRamp Gateway firmware version 7.0.0 where an administrator and a system user accounts are the only available user accounts for the gateway appliance.
Arbitrary code execution vlnerability in Operation bridge Manager, Application Performance Management and Operations Bridge (containerized) vulnerability in Micro Focus products products Operation Bridge Manager, Operation Bridge (containerized) and Application Performance Management. The vulneravility affects: 1.) Operation Bridge Manager versions 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, 10.63,10.62, 10.61, 10.60, 10.12, 10.11, 10.10 and all earlier versions. 2.) Operations Bridge (containerized) 2020.05, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05. 2018.02 and 2017.11. 3.) Application Performance Management versions 9,51, 9.50 and 9.40 with uCMDB 10.33 CUP 3. The vulnerability could allow Arbitrary code execution.
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
Because of hard-coded SSH keys for the root user in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series, Kami7B, an attacker may remotely log in through SSH.
WAC on the Sangfor Sundray WLAN Controller version 3.7.4.2 and earlier has a backdoor account allowing a remote attacker to login to the system via SSH (on TCP port 22345) and escalate to root (because the password for root is the WebUI admin password concatenated with a static string).
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
The backdoor account dnsekakf2$$ in /bin/login on DASAN H665 devices with firmware 1.46p1-0028 allows an attacker to login to the admin account via TELNET.
The MyCar Controls of AutoMobility Distribution Inc., mobile application contains hard-coded admin credentials. A remote unauthenticated attacker may be able to send commands to and retrieve data from a target MyCar unit. This may allow the attacker to learn the location of a target, or gain unauthorized physical access to a vehicle. This issue affects AutoMobility MyCar versions prior to 3.4.24 on iOS and versions prior to 4.1.2 on Android. This issue has additionally been fixed in Carlink, Link, Visions MyCar, and MyCar Kia.
Linear eMerge E3-Series devices allow Remote Code Execution (root access over SSH).
The rpWLANRedirect.asp ASP page is accessible without authentication on ZyXEL P-660HN-T1 V2 (2.00(AAKK.3)) devices. After accessing the page, the admin user's password can be obtained by viewing the HTML source code, and the interface of the modem can be accessed as admin.
Linear eMerge E3-Series devices have Hard-coded Credentials.
The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 contains multiple hard coded credentials for the Telnet and SSH interfaces.
The presence of a hardcoded account in Fortinet FortiWLC 7.0.11 and earlier allows attackers to gain unauthorized read/write access via a remote shell.
Zivif PR115-204-P-RS V2.3.4.2103 web cameras contain a hard-coded cat1029 password for the root user. The SONIX operating system's setup renders this password unchangeable and it can be used to access the device via a TELNET session.
REINER timeCard 6.05.07 installs a Microsoft SQL Server with an sa password that is hardcoded in the TCServer.jar file.
HCL AppScan Standard Edition 9.0.3.13 and earlier uses hard-coded credentials which can be exploited by attackers to get unauthorized access to the system.
A vulnerability in the Cisco Common Services Platform Collector (CSPC) could allow an unauthenticated, remote attacker to access an affected device by using an account that has a default, static password. This account does not have administrator privileges. The vulnerability exists because the affected software has a user account with a default, static password. An attacker could exploit this vulnerability by remotely connecting to the affected system using this account. A successful exploit could allow the attacker to log in to the CSPC using the default account. For Cisco CSPC 2.7.x, Cisco fixed this vulnerability in Release 2.7.4.6. For Cisco CSPC 2.8.x, Cisco fixed this vulnerability in Release 2.8.1.2.
Use of default credentials for the TELNET server in Petwant PF-103 firmware 4.3.2.50 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commands as the root user.
Arlo Basestation firmware 1.12.0.1_27940 and prior contain a hardcoded username and password combination that allows root access to the device when an onboard serial interface is connected to.
Black Box iCOMPEL 9.2.3 through 11.1.4, as used in ONELAN Net-Top-Box 9.2.3 through 11.1.4 and other products, has default credentials that allow remote attackers to access devices remotely via SSH, HTTP, HTTPS, and FTP.
Multiple vulnerabilities in the authentication mechanisms of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. For more information about these vulnerabilities, see the Details section of this advisory.
Multiple vulnerabilities in the authentication mechanisms of Cisco Data Center Network Manager (DCNM) could allow an unauthenticated, remote attacker to bypass authentication and execute arbitrary actions with administrative privileges on an affected device. For more information about these vulnerabilities, see the Details section of this advisory.
ECOA BAS controller is vulnerable to hard-coded credentials within its Linux distribution image, thus remote attackers can obtain administrator’s privilege without logging in.
A Hardcoded JWT Secret Key in metadata.py in AdaptiveScale LXDUI through 2.1.3 allows attackers to gain admin access to the host system.
D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices have a hardcoded password of wrgac25_dlink.2013gui_dir850l for the Alphanetworks account upon device reset, which allows remote attackers to obtain root access via a TELNET session.
A Use of Hard-coded Cryptographic Key issue was discovered in Korenix JetNet JetNet5018G version 1.4, JetNet5310G version 1.4a, JetNet5428G-2G-2FX version 1.4, JetNet5628G-R version 1.4, JetNet5628G version 1.4, JetNet5728G-24P version 1.4, JetNet5828G version 1.1d, JetNet6710G-HVDC version 1.1e, and JetNet6710G version 1.1. An attacker may gain access to hard-coded certificates and private keys allowing the attacker to perform man-in-the-middle attacks.
GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
An issue was discovered on PLANEX CS-W50HD devices with firmware before 030720. A hardcoded credential "supervisor:dangerous" was injected into web authentication database "/.htpasswd" during booting process, which allows attackers to gain unauthorized access and control the device completely; the account can't be modified or deleted.
An issue was discovered on Wireless IP Camera 360 devices. Remote attackers can discover a weakly encoded admin password by connecting to TCP port 9527 and reading the password field of the debugging information, e.g., nTBCS19C corresponds to a password of 123456.
An issue was discovered on Wireless IP Camera 360 devices. A root account with a known SHA-512 password hash exists, which makes it easier for remote attackers to obtain administrative access via a TELNET session.
The Versa Director uses PostgreSQL (Postgres) to store operational and configuration data. It is also needed for High Availability function of the Versa Director. The default configuration has a common password across all instances of Versa Director. By default, Versa Director configures Postgres to listen on all network interfaces. This combination allows an unauthenticated attacker to access and administer the database or read local filesystem contents to escalate privileges on the system. Exploitation Status: Versa Networks is not aware of this exploitation in any production systems. A proof of concept exists in the lab environment. Workarounds or Mitigation: Starting with the latest 22.1.4 version of Versa Director, the software will automatically restrict access to the Postgres and HA ports to only the local and peer Versa Directors. For older releases, Versa recommends performing manual hardening of HA ports. Please refer to the following link for the steps https://docs.versa-networks.com/Solutions/System_Hardening/Perform_Manual_Hardening_for_Versa_Director#Secure_HA_Ports This vulnerability is not exploitable on Versa Directors if published Firewall guidelines are implemented. We have validated that no Versa-hosted head ends have been affected by this vulnerability. All Versa-hosted head ends are patched and hardened. Please contact Versa Technical Support or Versa account team for any further assistance. Software Download Links: 22.1.4: https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4
A use of hard-coded credentials (CWE-798) vulnerability in FortiPortal versions 5.2.5 and below, 5.3.5 and below, 6.0.4 and below, versions 5.1.x and 5.0.x may allow a remote and unauthenticated attacker to execute unauthorized commands as root by uploading and deploying malicious web application archive files using the default hard-coded Tomcat Manager username and password.
A hard-coded cryptographic key vulnerability was identified in Red Lion Controls Sixnet-Managed Industrial Switches running firmware Version 5.0.196 and Stride-Managed Ethernet Switches running firmware Version 5.0.190. Vulnerable versions of Stride-Managed Ethernet switches and Sixnet-Managed Industrial switches use hard-coded HTTP SSL/SSH keys for secure communication. Because these keys cannot be regenerated by users, all products use the same key. The attacker could disrupt communication or compromise the system. CVSS v3 base score: 10, CVSS vector string: (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). Red Lion Controls recommends updating to SLX firmware Version 5.3.174.