The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
FirstUseAuthenticator is a JupyterHub authenticator that helps new users set their password on their first login to JupyterHub. When JupyterHub is used with FirstUseAuthenticator, a vulnerability in versions prior to 1.0.0 allows unauthorized access to any user's account if `create_users=True` and the username is known or guessed. One may upgrade to version 1.0.0 or apply a patch manually to mitigate the vulnerability. For those who cannot upgrade, there is no complete workaround, but a partial mitigation exists. One can disable user creation with `c.FirstUseAuthenticator.create_users = False`, which will only allow login with fully normalized usernames for already existing users prior to jupyterhub-firstuserauthenticator 1.0.0. If any users have never logged in with their normalized username (i.e. lowercase), they will still be vulnerable until a patch or upgrade occurs.
A hard coded password in Super Store Finder v3.6 allows attackers to access the administration panel.
Calibre-Web 0.6.6 allows authentication bypass because of the 'A0Zr98j/3yX R~XHH!jmN]LWX/,?RT' hardcoded secret key.
Multiple vulnerabilities in Oracle Java 7 before Update 11 allow remote attackers to execute arbitrary code by (1) using the public getMBeanInstantiator method in the JmxMBeanServer class to obtain a reference to a private MBeanInstantiator object, then retrieving arbitrary Class references using the findClass method, and (2) using the Reflection API with recursion in a way that bypasses a security check by the java.lang.invoke.MethodHandles.Lookup.checkSecurityManager method due to the inability of the sun.reflect.Reflection.getCallerClass method to skip frames related to the new reflection API, as exploited in the wild in January 2013, as demonstrated by Blackhole and Nuclear Pack, and a different vulnerability than CVE-2012-4681 and CVE-2012-3174. NOTE: some parties have mapped the recursive Reflection API issue to CVE-2012-3174, but CVE-2012-3174 is for a different vulnerability whose details are not public as of 20130114. CVE-2013-0422 covers both the JMX/MBean and Reflection API issues. NOTE: it was originally reported that Java 6 was also vulnerable, but the reporter has retracted this claim, stating that Java 6 is not exploitable because the relevant code is called in a way that does not bypass security checks. NOTE: as of 20130114, a reliable third party has claimed that the findClass/MBeanInstantiator vector was not fixed in Oracle Java 7 Update 11. If there is still a vulnerable condition, then a separate CVE identifier might be created for the unfixed issue.
D-Link DVX-2000MS contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file. As weak passwords have been used, the plaintext passwords can be recovered from the hash values.
An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A specially-crafted HTTP request can lead to unauthorized access. An attacker can send an HTTP request to trigger this vulnerability.
A vulnerability in the key-based SSH authentication mechanism of Cisco Policy Suite could allow an unauthenticated, remote attacker to log in to an affected system as the root user. This vulnerability is due to the re-use of static SSH keys across installations. An attacker could exploit this vulnerability by extracting a key from a system under their control. A successful exploit could allow the attacker to log in to an affected system as the root user.
ZPanel 10.0.1 has insufficient entropy for its password reset process.
Incorrect access control in TOTOLINK LR350 V9.3.5u.6369_B20220309 allows attackers to obtain the apmib configuration file, which contains the username and the password, via a crafted request to /cgi-bin/ExportSettings.sh.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
An issue was discovered in Polycom Web Management Interface G3/HDX 8000 HD with Durango 2.6.0 4740 software and embedded Polycom Linux Development Platform 2.14.g3. It has a blank administrative password by default, and can be successfully used without setting this password.
A Hardcoded JWT Secret Key in metadata.py in AdaptiveScale LXDUI through 2.1.3 allows attackers to gain admin access to the host system.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.
The Runtime Toolkit in CODESYS Runtime System 2.3.x and 2.4.x does not require authentication, which allows remote attackers to execute commands via the command-line interface in the TCP listener service or transfer files via requests to the TCP listener service.
The web application for ProGauge MAGLINK LX4 CONSOLE contains an administrative-level user account with a password that cannot be changed.
admin.php in SmartSiteCMS 1.0 allows remote attackers to bypass authentication and gain administrator privileges by setting the userName cookie.
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.
Multiple MachineSense devices have credentials unable to be changed by the user or administrator.
Multiple vulnerabilities in the Java Runtime Environment (JRE) component in Oracle Java SE 7 Update 6 and earlier allow remote attackers to execute arbitrary code via a crafted applet that bypasses SecurityManager restrictions by (1) using com.sun.beans.finder.ClassFinder.findClass and leveraging an exception with the forName method to access restricted classes from arbitrary packages such as sun.awt.SunToolkit, then (2) using "reflection with a trusted immediate caller" to leverage the getField method to access and modify private fields, as exploited in the wild in August 2012 using Gondzz.class and Gondvv.class.
GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
IBM Security Identity Manager 7.0.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 171511.
A settings manipulation vulnerability in NCR Terminal Handler v1.5.1 allows attackers to execute arbitrary commands, including editing system security auditing configurations.
The getUserzoneCookie function in Kaltura before 13.2.0 uses a hardcoded cookie secret to validate cookie signatures, which allows remote attackers to bypass an intended protection mechanism and consequently conduct PHP object injection attacks and execute arbitrary PHP code via a crafted userzone cookie.
Sielco PolyEco1000 is vulnerable to an authentication bypass vulnerability due to an attacker modifying passwords in a POST request and gain unauthorized access to the affected device with administrative privileges.
An issue in the login component (process_login.php) of Hotel Management System commit 79d688 allows attackers to authenticate without providing a valid password.
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls.
Unspecified vulnerability in the Java Runtime Environment (JRE) component in Oracle Java SE 7 Update 7 and earlier allows remote attackers to affect confidentiality, integrity, and availability, related to JAX-WS.
The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.
H3C R3010 v100R002L02 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root.
A use of hard-coded password vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to gain access through accounts using default passwords
A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries.
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by hard coded credentials. A hardcoded credential exist in /etc/tomcat8/tomcat-user.xml, which allows attackers to gain authorized access and control the tomcat completely on port 8000 in the tomcat manger page.
In D-Link DIR-860L REVA FIRMWARE PATCH 1.10..B04, the Telnet service contains hardcoded credentials, enabling attackers to log in remotely to the Telnet service and perform arbitrary commands.
D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service.
D-Link DIR-820LW REVB FIRMWARE PATCH 2.03.B01_TC contains hardcoded credentials in the Telnet service, enabling attackers to log in remotely to the Telnet service and perform arbitrary commands.
TX9 Automatic Food Dispenser v3.2.57 devices allow access to a shell as root/superuser, a related issue to CVE-2019-16734. To connect, the telnet service is used on port 23 with the default password of 059AnkJ for the root account. The user can then download the filesystem through preinstalled BusyBox utilities (e.g., tar and nc).
An authentication bypass was found in an unknown area of the SiteOmat source code. All SiteOmat BOS versions are affected, prior to the submission of this exploit. Also, the SiteOmat does not force administrators to switch passwords, leaving SSH and HTTP remote authentication open to public.
GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module.
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.
A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability.
Incorrect access control in Solar-Log 1000 before v2.8.2 and build 52- 23.04.2013 allows attackers to obtain Administrative privileges via connecting to the web administration server. Not existing for SL 200, 500, 1000 / fixed in 4.2.8 for SL 250, 300, 1200, 2000, SL 50 Gateway / fixed in 5.1.2 / 6.0.0 for SL Base.
Use of hard-coded credentials vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication using hard-coded administrator credentials. These accounts cannot be disabled.
TELSAT marKoni FM Transmitters are vulnerable to users gaining unauthorized access to sensitive information or performing actions beyond their designated permissions.
TELSAT marKoni FM Transmitters are vulnerable to an attacker exploiting a hidden admin account that can be accessed through the use of hard-coded credentials.
Dr. ID Door Access Control and Personnel Attendance Management system uses the hard-code admin default credentials that allows remote attackers to access the system through the default password and obtain the highest permission.
Studio 42 elFinder 2.1.64 is vulnerable to Incorrect Access Control. Copying files with an unauthorized extension between server directories allows an arbitrary attacker to expose secrets, perform RCE, etc.
Shenzhen Guoxin Synthesis image system before 8.3.0 has a 123456Qw default password.
Improper Access Control vulnerability in the patchesUpdate API as implemented in Bitdefender Endpoint Security Tools for Linux as a relay role allows an attacker to manipulate the remote address used for pulling patches. This issue affects: Bitdefender Endpoint Security Tools for Linux versions prior to 6.6.27.390; versions prior to 7.1.2.33. Bitdefender Unified Endpoint versions prior to 6.2.21.160. Bitdefender GravityZone versions prior to 6.24.1-1.