Weak Password Requirements in GitHub repository janeczku/calibre-web prior to 0.6.20.
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Calibre Web, Autocaliweb allows Blind OS Command Injection.This issue affects Calibre Web: 0.6.24 (Nicolette); Autocaliweb: from 0.7.0 before 0.7.1.
Improper Restriction of Excessive Authentication Attempts in GitHub repository janeczku/calibre-web prior to 0.6.20.
Server-Side Request Forgery (SSRF) in GitHub repository janeczku/calibre-web prior to 0.6.17.
Server-Side Request Forgery (SSRF) in GitHub repository janeczku/calibre-web prior to 0.6.18.
Server-Side Request Forgery (SSRF) in Pypi calibreweb prior to 0.6.16.
Calibre-Web before 0.6.18 allows user table SQL Injection.
calibre-web is vulnerable to Business Logic Errors
Server-Side Request Forgery (SSRF) in GitHub repository janeczku/calibre-web prior to 0.6.17.
Zohocorp ManageEngine DDI Central versions 4001 and prior were vulnerable to agent takeover vulnerability due to the hard-coded sensitive keys.
Multiple hardcoded credentials in Xsuite 2.x.
Hard-coded credentials are used by the CyberPower PowerPanel platform to authenticate to the database, other services, and the cloud. This could result in an attacker gaining access to services with the privileges of a Powerpanel business application.
Izanami is a shared configuration service well-suited for micro-service architecture implementation. Attackers can bypass the authentication in this application when deployed using the official Docker image. Because a hard coded secret is used to sign the authentication token (JWT), an attacker could compromise another instance of Izanami. This issue has been patched in version 1.11.0.
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
Ubiquiti U6-LR 6.6.65 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: In Ubiquiti's view there is no vulnerability as the Hardcoded Password should be after setup not before.
A security issue was discovered in the Kubernetes Image Builder versions <= v0.1.37 where default credentials are enabled during the image build process. Virtual machine images built using the Proxmox provider do not disable these default credentials, and nodes using the resulting images may be accessible via these default credentials. The credentials can be used to gain root access. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project with its Proxmox provider.
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.
MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs.
EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
TOTOLINK CP300 V2.0.4-B20201102 was discovered to contain a hardcoded password vulnerability in /etc/shadow.sample, which allows attackers to log in as root.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
KubePi is a k8s panel. The jwt authentication function of KubePi through version 1.6.2 uses hard-coded Jwtsigkeys, resulting in the same Jwtsigkeys for all online projects. This means that an attacker can forge any jwt token to take over the administrator account of any online project. Furthermore, they may use the administrator to take over the k8s cluster of the target enterprise. `session.go`, the use of hard-coded JwtSigKey, allows an attacker to use this value to forge jwt tokens arbitrarily. The JwtSigKey is confidential and should not be hard-coded in the code. The vulnerability has been fixed in 1.6.3. In the patch, JWT key is specified in app.yml. If the user leaves it blank, a random key will be used. There are no workarounds aside from upgrading.
Weak JWT Secret vulnerabilitiy in EasyVirt DCScope <= 8.6.0 and CO2Scope <= 1.3.0 allows remote attackers to generate JWT for privilege escalation. The HMAC secret used for generating tokens is hardcoded as "somerandomaccesstoken". A weak HMAC secret poses a risk because attackers can use the predictable secret to create valid JSON Web Tokens (JWTs), allowing them access to important information and actions within the application.
The Four-Faith F3x36 router using firmware v2.0.0 is vulnerable to authentication bypass due to hard-coded credentials in the administrative web server. An attacker with knowledge of the credentials can gain administrative access via crafted HTTP requests. This issue appears similar to CVE-2023-32645.
A Use of Password Hash Instead of Password for Authentication issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-IPC-HDW4XXX, DH-IPC-HFW1XXX, DH-IPC-HFW2XXX, DH-IPC-HFW4XXX, DH-SD6CXX, DH-NVR1XXX, DH-HCVR4XXX, DH-HCVR5XXX, DHI-HCVR51A04HE-S3, DHI-HCVR51A08HE-S3, and DHI-HCVR58A32S-S2 devices. The use of password hash instead of password for authentication vulnerability was identified, which could allow a malicious user to bypass authentication without obtaining the actual password.
Goldshell ASIC Miners v2.1.x was discovered to contain hardcoded credentials which allow attackers to remotely connect via the SSH protocol (port 22).
IBM Security Guardium 11.2 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 196313.
Amcrest IPM-721S V2.420.AC00.16.R.20160909 devices have default credentials that are hardcoded in the firmware and can be extracted by anyone who reverses the firmware to identify them. If the firmware version V2.420.AC00.16.R 9/9/2016 is dissected using binwalk tool, one obtains a _user-x.squashfs.img.extracted archive which contains the filesystem set up on the device that many of the binaries in the /usr folder. The binary "sonia" is the one that has the vulnerable function that sets up the default credentials on the device. If one opens this binary in IDA-pro, one will notice that this follows a ARM little endian format. The function sub_3DB2FC in IDA pro is identified to be setting up the values at address 0x003DB5A6. The sub_5C057C then sets this value and adds it to the Configuration files in /mnt/mtd/Config/Account1 file.
Brocade SANnav OVA before v2.3.1 and v2.3.0a contain hard-coded credentials in the documentation that appear as the appliance's root password. The vulnerability could allow an unauthenticated attacker full access to the Brocade SANnav appliance.
Use of Hard-coded Credentials in GitHub repository nuxtlabs/github-module prior to 1.6.2.
Use of hard-coded credentials vulnerability in SS1 Ver.13.0.0.40 and earlier and Rakuraku PC Cloud Agent Ver.2.1.8 and earlier allows a remote attacker to obtain the password of the debug tool and execute it. As a result of exploiting this vulnerability with CVE-2023-22335 and CVE-2023-22336 vulnerabilities together, it may allow a remote attacker to execute an arbitrary code with SYSTEM privileges by sending a specially crafted script to the affected device.
EMC Data Protection Advisor 6.3.x before patch 67 and 6.4.x before patch 130 contains undocumented accounts with hard-coded passwords and various privileges. Affected accounts are: "Apollo System Test", "emc.dpa.agent.logon" and "emc.dpa.metrics.logon". An attacker with knowledge of the password could potentially use these accounts via REST APIs to gain unauthorized access to EMC Data Protection Advisor (including potentially access with administrative privileges).
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom telnet daemon as a part of the busybox and retrieves the password from the shadow file using the function getspnam at address 0x00053894. Then performs a crypt operation on the password retrieved from the user at address 0x000538E0 and performs a strcmp at address 0x00053908 to check if the password is correct or incorrect. However, the /etc/shadow file is a part of CRAM-FS filesystem which means that the user cannot change the password and hence a hardcoded hash in /etc/shadow is used to match the credentials provided by the user. This is a salted hash of the string "admin" and hence it acts as a password to the device which cannot be changed as the whole filesystem is read only.
DragonWave Horizon 1.01.03 wireless radios have hardcoded login credentials (such as the username of energetic and password of wireless) meant to allow the vendor to access the devices. These credentials can be used in the web interface or by connecting to the device via TELNET. This is fixed in recent versions including 1.4.8.
Code Dx versions prior to 2023.4.2 are vulnerable to user impersonation attack where a malicious actor is able to gain access to another user's account by crafting a custom "Remember Me" token. This is possible due to the use of a hard-coded cipher which was used when generating the token. A malicious actor who creates this token can supply it to a separate Code Dx system, provided they know the username they want to impersonate, and impersonate the user. Score 6.7 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C
A hard-coded account named 'upgrade' in Fortinet FortiWLM 8.3.0 and lower versions allows a remote attacker to log-in and execute commands with 'upgrade' account privileges.
Intellinet NFC-30ir IP Camera has a vendor backdoor that can allow a remote attacker access to a vendor-supplied CGI script in the web directory.
An issue was discovered in Veritas NetBackup Before 8.0 and NetBackup Appliance Before 3.0. NetBackup Cloud Storage Service uses a hardcoded username and password.
SolarWinds Access Rights Manager (ARM) was found to contain a hard-coded credential authentication bypass vulnerability. If exploited, this vulnerability would allow access to the RabbitMQ management console. We thank Trend Micro Zero Day Initiative (ZDI) for its ongoing partnership in coordinating with SolarWinds on responsible disclosure of this and other potential vulnerabilities.
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
In some circumstances, an F5 BIG-IP version 12.0.0 to 12.1.2 and 13.0.0 Azure cloud instance may contain a default administrative password which could be used to remotely log into the BIG-IP system. The impacted administrative account is the Azure instance administrative user that was created at deployment. The root and admin accounts are not vulnerable. An attacker may be able to remotely access the BIG-IP host via SSH.
The Data Warehouse component in NetApp OnCommand Insight before 7.2.3 allows remote attackers to obtain administrative access by leveraging a default privileged account.
EMC ESRS Policy Manager prior to 6.8 contains an undocumented account (OpenDS admin) with a default password. A remote attacker with the knowledge of the default password may login to the system and gain administrator privileges to the local LDAP directory server.
DataEase is an open source data visualization analysis tool. Prior to 2.10.2, DataEase allows attackers to forge jwt and take over services. The JWT secret is hardcoded in the code, and the UID and OID are hardcoded. The vulnerability has been fixed in v2.10.2.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentials. An attacker could misuse the credentials to compromise the device locally or over the network.
Hard-coded credentials in AmosConnect 8 allow remote attackers to gain full administrative privileges, including the ability to execute commands on the Microsoft Windows host platform with SYSTEM privileges by abusing AmosConnect Task Manager.
Use of Hard-coded Credentials in GitHub repository alextselegidis/easyappointments prior to 1.5.0.